一、概述 ·········································································· 2 二、结构简介 ···································································· 2 三、注意事项 ···································································· 3 四、电气控制部分 ······························································ 4 五、安装 ·········································································· 6 六、启动、运行和停机 ························································ 7 七、维护 ·········································································· 8 八、质量保证 ···································································· 9
1
一、概述
磁力耦合器是一种力矩可调整的力矩耦合系统。它由两组相互独立,无机械连接的转子组成,由永磁体构成的转子叫磁转子,与负载连接,由铜(铝)板组成转子叫导体转子,与电动机连接。当电动机带动导体转子旋转时,与磁转子发生相对运动——切割磁力线,根据法拉第电磁感应定律,此时在导体中产生感生电流,此电流在永磁场中受到电磁力,电磁力的方向由左手定则决定。由电磁力产生电磁转矩,从而使磁转子、导体转子通过空气间隙传递力矩。调节磁转子和导体转子间的间隙——气隙,来改变磁场的磁通密度,使输出、输入轴之间的力矩、转差发生变化,得到一个可控的、可变的输出转速,从而达到无级调速的目的。 二、结构简介
自冷型磁力耦合器的主要部分见下图;它分为磁转子和导体转子两部分,分别用锥形胀套固定在负载轴和电机轴上,故在订货时,必须确定负载和电机轴的具体尺寸,以便订购相应的胀套。
调节轴承座上有螺旋槽,轴承座上装有滑块与螺旋槽配合,当调节轴承座在执行机带动下缓慢转动一个角度时,滑块就会带动轴承座沿轴向滑动,从而带动轴套、永磁体轴向滑动,另一永磁体由齿条、齿轮带动,向相反的方向移动,完成了气隙的调整。由于滑块与螺旋槽、齿轮和齿条之间,执行机、关节轴承与拉杆之间必须留有间隙,有空行程,故回调时,不会马上响应,存在滞后时间。
2
调节轴承座和轴承座内装有两对角接触轴承,采用油脂润滑、骨架油封密封。调节轴承座在轴向是固定的,圆周方向在调整气隙时作缓慢转动,转动角度小于85°。轴承座下方有一导向键卡在支座的键槽内,使其不能转动,轴向可移动20mm左右。由于支座的孔要允许轴承座的轴向运动,故它们之间采用很松的间隙配合,测量震动时,只需测负载轴承座处不超标即可。
三、注意事项
施工前请仔细阅读下列注意事项:
1)磁场可能导致起搏器,防颤器,或其他医疗设备误动作或参数重
3
置。佩带此类医疗设备的人,在磁力耦合器拆开时,必须与磁力耦合器保持2m以上的安全距离!
2) 当磁力耦合器运行前,应清理好场地,松散的物品容易被磁力耦合器高速旋转带的强风吹走。
3) 当磁力耦合器运行时,眼部带好防护,防止宽松的服装、长头发、首饰被卷入设备内。
4)不要把手放在磁转子与导体转子之间,防止被挤压。
5)铁质金属很容易被磁铁吸引,一旦吸住很难分开,所以应注意让导体零件,工具,紧固件,工作台金属面远离磁体。
6)磁性存储器(磁卡、信用卡等)暴露在磁场时可能受损坏。 7)手机、电脑等电子设备放在磁场环境中可能受到不利影响。 四、电气控制部分
电气控制部分的作用是控制角行程执行机,使之牵引磁转子作轴向移动,调整气隙的大小,从而控制转速的高低,电控箱的屏幕上能显示转速的高低。注意;决定气隙大小的依据是水泵、风机的压力、流量要求,转速仅作为参考。 1.内部线路图:见附件1 2.面板说明:
电源指示:指示灯亮,表示控制箱供电正常。
人机界面:可显示气隙(导体转子、磁转子之间间隙)大小数值以及其位置状态模拟、执行机位置反馈、负载端转速等信息。