Lubricate the joints (b and d) with a suitable stopcock grease designed for use with organic solvents, and connect the scrubber unit to the absorber tube (e). Transfer 3.0 mL of to the absorber tube. Add 3.0 g of granular zinc (No. 20 mesh) to the mixture in the flask, immediately connect the assembled scrubber unit, and allow the evolution of hydrogen and the color development to proceed at room temperature for 45 minutes, swirling the flask gently at 10-minute intervals. Disconnect the absorber tube from the generator and scrubber units, and transfer the absorbing solution to a 1-cm absorption cell. Any red color produced by the Test Preparation does not exceed that produced by the Standard Preparation. If necessary or desirable, determine the absorbance at the wavelength of maximum absorbance
between 535 and 540 nm, with a suitable spectrophotometer or colorimeter, using as the blank.
Interfering Chemicals— Metals or salts of metals, such as chromium, cobalt, copper, mercury, molybdenum, nickel, palladium, and silver, may interfere with the evolution of arsine. Antimony, which forms stibine, produces a positive interference in the color development with ; when the presence of antimony is suspected, the red colors produced in the two silver diethyldithiocarbamate solutions may be compared at the
wavelength of maximum absorbance between 535 and 540 nm, with a suitable colorimeter, since at this wavelength the interference due to stibine is negligible.
METHOD II
NOTES—
(1) Caution—Some substances may react with explosive violence when digested with hydrogen peroxide. Exercise safety precautions at all times.
(2) If halogen-containing compounds are present, use a lower temperature while heating the test specimen with sulfuric acid, avoid boiling the mixture,