(续表2)

$T17.02018.01519.02120.02021.01722.02023.01524.01625.01626.018

应用光学 2005,26(5)   李旭东,胡铁力,岳文龙,等:红外热像仪SiTF测试研究

造成SiTF波动的可能原因:(1)待测热成像

外界信号253.0255.0255.0255.0255.0255.0255.0255.0255.0255.0

$信号67.266.966.967.067.367.467.567.567.667.6

Cnts信号185.8188.1188.0188.0187.7187.6187.5187.5187.4187.4

参考文献:

[1] BellPA,HooverCW.StandardNETDTestProce-dureforFLIRsystemswithvideoOutputs,inin-fraedimagingsystems:design,analysis,modelingandtesting[J].SPIE1993,1969:194-205.

[2] FlanneryRE,MillerJE.Statusofuncooledinfr-aredimagingsystems:design,analysis,modelingandtestingⅢ[J].SPIE,1992.1989:379-395.[3] OwenPR,CommandMA,RedstoneArs-enal.

Developmentofautomatedproceduresforex-pedi-entandcost-efficientacceptancetestingofimaginginfraredsystems,ininfraredImagingSystems:De-sign,Analysis,ModelingandTestingⅨ[J].SPIE,2000,4030:42-49.

系统和评估系统的光学透过率较低或其光学系统受到污染;(2)CosineH的影响;(3)有渐晕或有别的寄生信号产生;(4)待测热成像系统探测器的响应度较低(探测元或致冷器损坏);(5)靶标或背景黑体受到污染造成的发射率降低;(6)探测器受温度的波动影响较大;(7)测试期间环境温度发生了变化;(8)测试期间评估系统AGC被激活了;(9)给出了M修正;(10)输入$T的非线性引起的非线性响应。

N

4 结果讨论

由于待测红外热成像系统受其自身光学系统、电子线路、探测器和制冷器等因素的影响,加之评估系统受其本身测试精度和环境变化等的影响,从而造成SiTF波动的原因很多。当SiTF的测试结果出现波动时,有时并不能对造成波动的可能因素作出准确的评价。作者在前人工作的基础上总结出所测热成像系统的SiTF可能产生波动的原因,供评估系统分析员、热成像系统设计人员和热成像系统用户参考。

美国海军装备研制新招数

当前,美国海军虽然面临裁减军备、裁减人员和裁减军费,但为在2000年以后能继续保持海上霸主地位,正从大到航空母舰装备编制改革,中到研制潜载型遥控深潜器,小到用驳船改装导弹舰实弹发射,不断推出新招。

一招曰:潜载遥控潜水器;二招曰:驳船改装导弹舰;三招曰:航母减机又增效;四招曰:潜艇设计模块化。

由上述美国海军装备研究试验的新动向,可见科技进步促使其不断推出新招,但其实质仍是为了从多方位增强2000年后的海上霸主地位。