B. Product Performance
4. Sub clause of Part 1 does not apply.
5. Sub clause of Part 1 does not apply.
the average input current obtained from the inputs measured in 1.A.3. Cycling shall consist of a 5 minutes “on” time followed by 5 minutes “off”. All orbital saws must be set in the non-orbital position prior to life testing. Evaluate to the requirements of the appropriate PEAC. Life test no. 2 does not apply. Life test no. 3 does not apply. Life test no. 4 does not apply.
B. Lab Use Test - Lab Use Test - Test five (5) samples to PEAC requirements. Use test should be performed in the following sequence: (All use testing shall be performed at the highest speed setting unless otherwise noted. Low speed indicates a multiple range gear box. If the product is variable speed only, without gear box selection, perform all use test in the highest speed range.)
1. Three (3) hours cutting ½” plywood with six (6) tooth/inch wood cutting blade. Cutting time should be divided in the following manner:
a) Sabre Saws
One (1) hour cutting straight Two (2) hours cutting curves b) Scroller Saws
One (1) hour cutting straight
One (1) hour cutting curves with the sawbar locked One (1) hour cutting curves by scrolling c) Orbiting Jig Saws
Two (2) hours cutting straight (1/2 hour in each orbit setting) One (1) hour cutting curves in non-orbit setting
2. One-half (1/2) hour cutting 1/4” steel plate with twenty-four (24) tooth/inch metal cutting blade.
Test shall be performed in orbital position if it applies to the sample.
Page 2 of 4
A. Perform loaded cycling on each of eight (8) samples, utilizing the paddle fixture. Samples are to be loaded to
6. Sub clause of Part I does not apply.
7. Sub clause of Part 1 does not apply.
8. Abuse Test – Perform 200 plunge cuts into ½” plywood with a seven (7) tooth/inch wood cutting blade. Evaluate to the requirements of the appropriate PEAC.
ADDITIONS
9. Measure and record base flatness on five (5) samples. Evaluate to the requirements of the appropriate PEAC.
R00