17-5
Air at 320 K is flowing in a duct. The temperature that a stationary probe inserted into the duct will read is to be determined for different air velocities. Assumptions The stagnation process is isentropic.
Properties The specific heat of air at room temperature is cp = 1.005 kJ/kg K. Analysis The air which strikes the probe will be brought to a complete stop, and thus it will undergo a stagnation process. The thermometer will sense the temperature of this stagnated air, which is the stagnation temperature, T0. It is determined from
V2
T0 T . The results for each case are calculated below:
2cp
1 kJ/kg (1 m/s)2 320.0 K (a) T0 320 K+
222 1.005 kJ/kg K m/s 1000(10 m/s)2 1 kJ/kg
K (b) T0 320 K+ 320.1
2 1.005 kJ/kg K 1000 m2/s2 (100 m/s)2 1 kJ/kg
(c) T0 320 K+ 325.0 K
2 1.005 kJ/kg K 1000 m2/s2 (1000 m/s)2 1 kJ/kg
(d) T0 320 K+ 817.5 K 222 1.005 kJ/kg K 1000 m/s
Discussion Note that the stagnation temperature is nearly identical to the
thermodynamic temperature at low velocities, but the difference between the two is significant at high velocities.
17-8
Air flows through a device. The stagnation temperature and pressure of air and its velocity are specified. The static pressure and temperature of air are to be determined. Assumptions 1 The stagnation process is isentropic. 2 Air is an ideal gas.
Properties The properties of air at an anticipated average temperature of 600 K are cp = 1.051 kJ/kg K and k = 1.376.
Analysis The static temperature and pressure of air are determined from
(570 m/s)2V2 1 kJ/kg
T
T0 673.2 518.6 K 222cp2 1.051 kJ/kg K 1000 m/s