Vd=1.2?77.1924+1.4?19.5069+0.7?(1.4?1.1899-1.4?7.1680)=114.0820kN
Nk=1548.9465+89.2512+10.3948-7.2929=1641.2996kN
?0Vd=114.0820kN
Afvd?11?fNk?0.9?0.09?1000+?0.7?1641.2996=901.4408 kN>114.0820kN,1.41.4符合规定
6.2.3不计温度作用
温度作用不计,计算如下
Vd=1.2?77.1924+1.4?19.5069+0.7?1.4?1.1899=121.6064kN
Nk=1548.9465+89.2512+10.3948=1648.5925 kN
?0Vd=121.6064kN
11?fNk?0.9?0.09?1000+?0.7?1648.5925=905.2963 1.41.4kN>121.6064kN, 符合规定
Afvd?7.预拱度值的计算
当施工时拱顶的最大下沉量?max=4cm,此时拱圈各等分点的预拱度值和拱圈各等分点的拱背施工时的y1坐标计算结果如下表所示
各等分点和预拱度值和拱背施工时y1坐标 图7-1
截面号 0 1 2 3 4 5 6 7 8 9 y/f 1.000000 0.810048 0.647289 0.508471 0.390820 0.291988 0.210000 0.143218 0.090308 0.050213 y(m) 7.7291 6.2609 5.0030 3.9300 3.0207 2.2568 1.6231 1.1069 0.6980 0.3881 X(m) 19.31544 17.70582 16.09620 14.48658 12.87696 11.26734 9.65772 8.04810 6.43848 4.82886 - 26 - ?4x2????max??1?l2??(cm) 0??0 0.0064 0.0122 0.0175 0.0222 0.0264 0.0300 0.0331 0.0356 0.0375 y1?y?? (m) 7.7291 6.2545 4.9908 3.9125 2.9943 2.2304 0.5931 1.0738 0.6624 0.3506 10 11 12 0.022133 0.005506 0 0.1711 0.0426 0 3.21924 1.60962 0 0.0390 0.0397 0.04 0.1321 0.0029 -0.04 - 27 -