102.Code 5583: “+12v - voltage low” (Warning) “+12v - 电压低”

103.Code 5640: “lamp power supplies - zero lamp power supplies detected” (Error)

“灯电源 - 没有探测到灯电源” 状态 两电源模块其中之一主供电电缆断开 解决方法 检查电源模块上MAINS INPUT插槽及插线 电源模块中“CTRL IN”与“CTRL OUT”检查电源模块中“CTRL IN”与“CTRL 插线断开 OUT”插槽及插线 电源模块未安装到位 灯电源控制板失灵 灯电源模块闪红灯 重新安装 更换 更换电源模块 104.Code 5641: “lamp power supplies - lamp is on, but smps is off” (Error) 状态 开关电源板失灵 灯电源模块失灵 电源背板失灵 更换 更换 更换 解决方法 105.Code 5642: “lamp power supplies - at least one lamp power supply could not be detected” (Error) 参见5640

106.Code 5643: “lamp power supplies - communication failed with at least one lamp power supply”(Error) 参见5640

107.Code 5644: “lamp power supplies - lamp is on, but at least one lamp power supply is off” (Error) 参见5640

11

108.Code 5646: “lamp - set lamp on failed” (Error) “灯 - 点灯失败” 状态 氙灯有触发,无法持续点燃 解决方法 1,氙灯寿命将尽,更换新灯 2,触发器损坏 109.Code 5647: “lamp - lamp is off due to an error” (Error) “灯 - 由于一个错误氙灯已熄灭” 状态 解决方法 由于某些错误,灯电源被指令熄灭氙灯 查看放映机日志寻找其他错误信息,首先解决此类错误问题 灯电源故障 查看灯电源指示灯,若红灯闪烁则更需换灯电源 更换新灯 氙灯缺陷 110.Code 5654: “lamp run time - read failed” (Error) “灯运行时间 - 读取失败”

111.Code 5657: “lamp run time - exceeds maximum” (Error) “灯运行时间 - 已到最大寿命” 状态 灯箱内氙灯已达到最大使用寿命 解决方法 更换新灯,或重置灯信息 112.Code 5658: “lamp run time - read limits failed” (Error) “灯运行时间 - 限制读取失败”

113.Code 5659: “lamp run time - warning” (Warning) 状态 灯箱内氙灯接近到最大使用寿命 解决方法 尽快更换新灯,或重置灯信息 114.Code 5800: “ti-boards - system status = fail” (Error) “TI板 - 系统状态=失败”

这是一个通用TI错误代码,需要进入触摸屏的“诊断-测试-自检”中勾选所

12

有选项并进行检测,并将检测结果提供给服务商用以查找具体故障所在。 115.Code 5801: “ti-boards - security error, please authorize” (Error) “TI板 - 安全错误,请授权” 状态 放映机的输入或通讯组件被物理重置 解决方法 使用授权钥匙进行重新授权,步骤如下 1,确保重置部件正确安装 2,开启放映机 3,将授权钥匙嵌入授权插槽 4,在5秒内输入口令 放映机内盖被拆开(光处理器部分) 安全开关失灵 方法同上 如果执行以上方法仍无效,更换DCI安全开关 如果更换安全开关无效则更换电源背板 电源背板失灵 116.Code 5802: “ti-boards - power up self test = fail” (Error) “TI板 - 开机自检 - 失败”

117.Code 5803: “ti-boards - interface board arm status = fail” (Error) “TI板 - 接口板装载状态 = 失败”

118.Code 5804: “ti-boards - interface board fpga load status = fail” (Error) “TI板 - 接口板FPGA装载状态 = 失败”

119.Code 5805: “ti-boards - processor board dsp status = fail” (Error) “TI板 - 运算板DSP状态 = 失败”

120.Code 5806: “ti-boards - processor board fpga load status = fail” (Error) “TI板 - 运算板FPGA装载状态 = 失败”

121.Code 5807: “ti-boards - read system status failed” (Error) “TI板 - 系统状态读取失败”

122.Code 5810: “ti-boards - read power-good failed” (Error)

13

“TI板 - 读取电源状态失败”

123.Code 5811: “ti-boards - power-good = fail” (Error) “TI板 - 电源正常信号 = 失败”

124.Code 5820: “ti-boards - interface board security enclosure error - replace interface board” (Error)

“TI板 - 接口板安全外壳错误 - 更换接口板”

125.Code 5880: “dolby 3d key-server - read status failed” (Warning) “杜比3D服务 - 状态读取失败”

126.Code 5881: “dolby 3d key-server - status = locked” (Warning) “杜比3D服务 - 状态 = 锁定”

127.Code 5882: “3d module - read status failed” (Warning) “杜比3D模块 - 状态读取失败”

128.Code 5885: “3d module - change status failed due to communication error” (Error)

“杜比3D模块 - 由于通讯故障导致的状态更新失败” 129.Code 5890: “3d module - color wheel spin failed” (Error) “杜比3D模块 - 色轮旋转失败”

130.Code 5891: “3d module - color wheel in failed” (Error) “杜比3D模块 - 色轮嵌入失败”

131.Code 5892: “3d module - color wheel out failed” (Error) “杜比3D模块 - 色轮撤出失败”

132.Code 5893: “3d module - color wheel temperature too high” (Error) “杜比3D模块 - 色轮温度过高”

133.Code 5894: “3d module - color wheel speed not ok (not locked)” (Error) “杜比3D模块 - 色轮转速不正常(未锁定)”

134.Code 5960: “light pipe - temperature too high” (Error) “光路 - 温度过高”

14

状态 液冷循环中断 光处理器的液冷管道被错误连接 解决方法 检查液冷循环管道是否正常 将光处理器的液冷管道与冷却泵和换热器重新连接 检查冷却泵电压 清理或更换放映机下部的滤网 冷却泵未启动 换热器的抽气滤网堵塞 冷却液不足,冷却泵抽气并且运行声音排除冷却循环中的空气,重新添加冷却变大 液 液冷循环系统故障,开启补充模式时感1,检查泵电压 觉不到冷却泵的振动 2,排出所有冷却液,打开冷却泵查看其转子是否被阻塞 温感器失灵 氙灯位置有误 反射镜位置有误 更换 重新调整氙灯位置 调整反射镜位置 135.Code 5961: “light pipe - temperature high” (Warning) “光路 - 温度高” 同5960

136.Code 5964: “light pipe - temperature sensor open” (Error) “光路 - 温感器断路”

137.Code 5965: “light pipe - temperature sensor short” (Error) “光路 - 温感器短路”

138.Code 5970: “dmd red front - temperature too high” (Error) “红DMD前端 - 温度过高”

139.Code 5971: “dmd red front - temperature high” (Warning) “红DMD前端 - 温度高”