§1.5.4 3.4.Waining类分析
§1.5.4.1 3.4.1、代号:BEA-170011 §例举信息
####
§BEA- 代码分析
BEA-170011
Warning: The LogBroadcaster on this server failed to broadcast log messages to the admin server. The Admin server may not be running. Message broadcasts to the admin server will be disabled.
Description
The LogBroadCaster on the managed server could not find a reference to the DomainLogHandler on the admin server. Messages from this server will not be logged in the domain log.
Cause The managed server might not be able to reach the admin server. One of the possible causes could be due to the admin server being shutdown. Action
To fix this problem, inspect the exception stack trace, correct the problem. If the admin server is shutdown, restart it to resume normal log broadcasta to the domain. 错误分析 这是由于在配置服务器端的broadcast ip指向一个不存在的IP引发的,目前系统没有用到广播功能。
§1.5.4.2 3.4.2、代号:BEA-100089 §例举信息
BEA-100089> (8983270560839801745S:10.150.208.4:[7010,7010,-1,-1,-1,-1,-1]:YXDomain:weblogic_a1) nor the secondary (6245526094817342656S:10.150.208.5:[7040,7040,-1,-1,-1,-1,-1]:YXDomain:weblogic_b2). The request URL was: http://10.150.208.3:80/epm/component.do> §发生次数1114 §BEA- 代码分析 BEA-100089 Warning: The session id: sessionID has been accessed from currentServer, a server that is neither the primary (primaryServer) nor the secondary (secondaryServer). The request URL was: requestUrl Description The session id: sessionID has been accessed from currentServer, a server that is neither the primary (primaryServer) nor the secondary (secondaryServer). Repeated occurrences of this can cause memory problems and performance degredation, as sessions are loaded into memory on more than two servers at a time. Cause The most likely cause is a configuration error on a front end hardware loadbalancer or webserver plugin. They should be configured to respect the values of primary/secondary in the cookie (i.e., stickyness), when possible. Action Please ensure that the front end webserver or load-balancer has been properly configured. 错误分析 由上下文 #### <> <> <1179195222812> session id: CgGgGL3NgyBpGjq82ZLsLhyRVgJGHydnQ7ZZCwHpqnWfZ7hSMb0K has been accessed from -8305630332285958955S:10.150.208.4:YXDomain:weblogic_a2, a server that is neither the primary (8983270560839801745S:10.150.208.4:[7010,7010,-1,-1,-1,-1,-1]:YXDomain:weblogic_a1) nor the secondary (6245526094817342656S:10.150.208.5:[7040,7040,-1,-1,-1,-1,-1]:YXDomain:weblogic_b2). The request URL was: http://10.150.208.3:80/epm/component.do> 可以看出是由于第一次访问时连到的机器是7010端口,而在取session时是取到7040端口。即两台节点服务器的级别是同等的。若要解决这个问题,可指定session复制或服务器FailOver形式。 §1.6 4、BEA代码段分析 Range Subsystem Cluster Catalog Cluster BEA-000100 - BEA-000199 BEA-000200 - BEA-000399 WebLogicServer T3Srvr Socket Socket BEA-000400 - BEA-000499 000500 - 000599 BEA-000600 - BEA-000699 BEA-000700 - BEA-000799 BEA-000800 - BEA-000899 BEA-000900 - BEA-000999 BEA-001000 - BEA-001999 BEA-002000 - BEA-002499 BEA-002500 - RJVM Common T3Misc Kernel Net JDBC IIOP DRS RJVM Common T3Misc Kernel Net JDBC IIOP DRS BEA-002600 BEA-002601 - BEA-002799 WebLogicServer Server BEA-002800 - BEA-002899 BEA-010000 - BEA-019999 020000 - 020099 BEA-040000 - BEA-045000 BEA-045000 - BEA-050000 BEA-050000 - BEA-059999 BEA-080000 - BEA-089999 BEA-090000 - BEA-100000 BugReporter EJB I18N JMS JMSExceptions JNDI RMI Security BugReporter EJB L10n JMS JMSException JNDI RMI Security BEA-099000 - BEA-100000 BEA-100000 - BEA-100999 BEA-101000 - BEA-109999 BEA-110000 - BEA-119999 BEA-130000 - BEA-139999 BEA-140000 - BEA-149999 BEA-145000 - BEA-146000 BEA-149000 - BEA-149199 BEA-149200 - BEA-149299 Security HTTP Session HTTP JTA XML Management Management Deployer Deployer Management Entitlement HTTPSession HTTP TX XML Management Commo DeployerRuntime SlaveDeployer MasterDeployer