某高层综合楼建筑给排水设计

2019-09-01 10:57

皖西学院本科毕业设计

目录

摘要 2222222222222222222222222222222222 3 设计说明书 2222222222222222222222222222222 4

1.给水工程 22222222222222222222222222222 4

1.1设计资料 22222222222222222222222222 4 1.2设计原则 22222222222222222222222222 4 1.3方案比较 22222222222222222222222222 4

方案一:无分区无水箱供水方式 2222222222222222方案二:设水泵水箱给水方式 22222222222222222方案三:变频泵调速供水 22222222222222222222.排水工程 222222222222222222222222222222.1方案选择 222222222222222222222222222.2排水系统的组成 222222222222222222222222.3系统流程图 22222222222222222222222223.消防给水工程 2222222222222222222222222223.1室内消火栓系统 222222222222222222222223.1.1消防水池 222222222222222222222223.1.2消防水泵和消防水泵房 222222222222222223.1.4消防水箱 222222222222222222222223.1.5消防水泵接合器 222222222222222222223.1.6减压阀及减压孔板 22222222222222222223.2自动喷水灭火系统 22222222222222222222223.2.1闭式喷头 222222222222222222222223.2.2报警阀门 222222222222222222222223.2.3水流指示器 22222222222222222222223.2.4水力警铃 222222222222222222222223.2.5延迟器 2222222222222222222222223.2.6末端试水装置 2222222222222222222223.2.7自动排气阀 22222222222222222222223.2.8自动喷水灭火系统给水分区和系统图式2 2 2 2 2 2 23.2.9自动喷水灭火系统的设计和计算2 2 2 2 2 2 2 2 2

第1页

4 5 5

6

6 6 6 6

7

8 9 10 11 12 13

15 18 19 19 20 20 20 21 21

皖西学院本科毕业设计

设计计算书 2222222222222222222222222222222 22

1.给水系统 22222222222222222222222222222 22

1.1给水用水定额及变化系数 2222222222222222222 23 1.2最高日用水量计算 2222222222222222222222 23 1.3最高日最大时用水量计算 2222222222222222222 23 1.4设计秒流量计算 22222222222222222222222 23 1.5高位水箱容积计算 22222222222222222222221.6贮水池计算 22222222222222222222222221.7生活给水系统水力计算 222222222222222222222.排水系统 222222222222222222222222222222.1排水定额 222222222222222222222222222.2污水、废水系统水力计算 22222222222222222223.消防系统 222222222222222222222222222223.1消火栓系统水力计算 2222222222222222222223.2自动喷水灭火系统水力计算 222222222222222222致谢 2222222222222222222222222222222222参考文献 22222222222222222222222222222222

第2页

25 27 28 36

36 36 50

50 57

62 63

皖西学院本科毕业设计

合肥市某高层综合楼建筑给排水设计

作者: 指导教师:

摘 要

本设计是十九层综合楼的建筑给排水设计,主要包括给水系统、排水系统、消防系统。本建筑生活用水由地下生活水泵房供给,给水系统采用分区供水,地下一层到六层为一区,七层到十二层为二区,十三层到十九层为三区,由生活水泵房中的微机变频调速水泵机组供水。排水系统采用 污、废水合流制,室内一层及以上污废水重力自流排入室外污水管道。污水经化粪池处理后,排入市政污水管。本工程消火栓给水系统用水由地下消防水泵房供给。消防水池与生活贮水池合用,有效容积为400m。本工程消防系统为湿式系统,竖向分为两个区:地下一层至十一层为低区;十二层至十九层为高区。在建筑屋顶消防水箱间内设置消防水箱,供消火栓系统初期灭火用水,与喷洒系统合用。消火栓系统采用两路供水,水平管与竖向管构成环状。本工程地下及地上六层均设自动喷水灭火系统,系统用水由地下消防水泵房供给,与室内消火栓系统合用。消防泵房内设喷洒泵两台,一用一备。由湿式报警阀直接控制喷洒水泵启动。 关键词:

给水排水工程;高层建筑;综合办公楼;自动喷水灭火系统

3

Abstract

This design is the 19th floor complex building of water supply and drainage design, including water supply system, drainage system, firefighting system. This building domestic water from underground life water supply pump room, water supply system using water rationing, to six layer for the underground layer area, seven to ten second into two areas, thirteen layer to the 19th floor to three areas, by the living computer frequency control of motor speed of pump house water pump water supply unit. Drainage system adopts the system of sewage, waste water confluence, gravity artesian interior layer and above the dirt wastewater discharged into sewer outside. Sewage after treated by septic tank, into the municipal sewage pipe. This project by the underground fire hydrant water supply system water supply water pump room. Pooling of water storage tank fire pool and life, the effective volume of 400 m. The project of fire protection system for wet system, vertical is divided into two areas: underground for low layer to eleven area; 10 second to 19th floor is high area. Between the water tank on the roof of a building fire water tank is installed inside, for early fire hydrant system and water pooling with spraying systems. Two road, water supply, fire hydrant system adopts the horizontal tube and vertical tube forming ring. Underground project to six layers has the automatic sprinkler system, system supplied by the underground fire water pump room, water and indoor fire hydrant system and operable. Fire pump room with two spray pump, one with a case. Directly controlled by wet alarm valve spray pumps are turned on. Key words:

Water supply and drainage engineering; High-rise building; The comprehensive office building; Automatic sprinkler system

3

第3页

皖西学院本科毕业设计

设计说明书

1.给水工程 1.1设计资料

根据设计资料,本建筑为合肥市的一栋高层综合楼——百花苑大厦,本建筑高92.55米,建筑面积约为20000平方米,另有地下室一层,地下层高4.80米,首层内地面标高为±0.000米,层高4.20米,二至五层层高3.60米,六层层高3.90米,其余各层层高为5.25米。 1.2设计原则

a、保障用水的安全可靠;

b、设备及管道的布置尽量简洁、集中,以便于检修; c、管道及设备的布置尽量便于装修,使综合楼美观。 1.3方案比选

方案一:无分区无水箱的供水方式

本方案采用多台水泵并联,根据水泵出水量或水压调节水泵运行台数。 方案示意图如下:

图1.1

优点:供水较可靠,设备布置较集中,便于维护和管理,不占用建筑上层使用面积。 缺点:水泵型号和数量比较多,投资较大,水泵控制调节比较麻烦,管道布置较复杂。 方案二:设水泵和水箱的给水方式

第4页

皖西学院本科毕业设计

在地下室设置水池,由水泵将水池中水供至屋顶水箱,水池水源来自市政管网供水。其方案示意图如下: 、

图1.2

优点:水泵能及时向水箱供水,可缩小水箱容积,又因水箱有调节作用,水泵出水量稳定,能保持在高效区运行。

缺点:可能造成二次污染,增加建筑荷载。 方案三:变频泵调速供水方式

优点:不设置屋顶水箱,减小占地面积与建筑荷重,无二次污染供水水质好,设备便于自动控制,管理简便,控制精度高运行可靠;水泵可以软启动,降低了对电网供电量的需求,减少了水泵机组的机械冲击和磨损及水泵切换时的震荡现象因而延长了水泵的寿命;设备一般为一体化装置,体积小,占地少。

缺点:不能满足消防贮水量,存在小流量和零流量的供水问题;一次性投入价格较高。

考虑到综合楼对环境卫生的要求,本次设计中采用变频泵供水方式供水。考虑到尽量利用市政管网水压力,并且方便管理,节省电耗等因素,将综合楼给水分为三个区,低区为-1—6层,由市政管网供水,中区为7—12层,高区为13—19层,由变频泵供水。 4、室内给水系统组成

第5页