表2 钢管截面特性和力学性能表

序号 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 规格 (mm) 标示 Φ89x4 Φ114x4 Φ140x4 Φ159x4 Φ159x5 Φ168x4 Φ168x5 Φ194x5 Φ194x6 Φ219x5 Φ219x6 Φ273x6 Φ273x7 Φ325x6 Φ325x7 Φ325x8 Φ356x6 Φ356x7 Φ356x8 Φ377x7 Φ377x8 Φ406x7 Φ406x8 管径 89 114 140 159 159 168 168 194 194 219 219 273 273 325 325 325 356 356 356 377 377 406 406 壁厚 4 4 4 4 5 4 5 5 6 5 6 6 7 6 7 8 6 7 8 7 8 7 8 截面 面积 (cm2) 10.681 13.823 17.090 19.478 24.190 20.609 25.604 29.688 35.437 33.615 40.150 50.328 58.496 60.130 69.932 79.671 65.973 76.749 87.462 81.367 92.740 115.296 87.745 100.028 124.407 105.055 130.690 156.074 112.846 140.429 167.761 118.627 147.655 176.432 204.958 156.451 186.988 217.273 每米 重量 (Kg/m) 8.38 10.85 13.42 15.29 18.99 16.18 20.10 23.31 27.82 26.39 31.52 39.51 45.92 47.20 54.90 62.54 51.79 60.25 68.66 63.87 72.80 90.51 68.88 78.52 97.66 82.47 102.59 122.52 88.58 110.24 131.69 93.12 115.91 138.50 160.89 122.81 146.79 170.56 惯性矩 (cm4) 96.68 209.35 395.47 585.33 717.88 693.28 851.14 1326.54 1567.21 1925.34 2278.74 4487.08 5177.30 7651.33 8844.02 10013.92 10105.15 11689.85 13246.99 13928.95 15791.85 19425.87 17466.68 19814.11 24401.82 22952.91 28287.25 33466.24 28446.36 35091.32 41556.30 33044.61 40789.65 48335.27 55684.90 48520.25 57536.08 66331.14 截面模量 (cm3) 21.73 36.73 56.50 73.63 90.30 82.53 101.33 136.76 161.57 175.83 208.10 328.72 379.29 470.85 544.25 616.24 567.71 656.73 744.21 738.94 837.76 1030.55 860.43 976.06 1202.06 1077.60 1328.04 1571.18 1244.92 1535.73 1818.66 1376.86 1699.57 2013.97 2320.20 1910.25 2265.20 2611.46 回转 半径 (cm) 3.009 3.892 4.810 5.482 5.448 5.800 5.766 6.684 6.650 7.568 7.534 9.442 9.408 11.280 11.246 11.211 12.376 12.341 12.307 13.084 13.049 12.980 14.109 14.074 14.005 14.781 14.712 14.643 15.877 15.808 15.739 16.690 16.621 16.552 16.483 17.611 17.541 17.473 径 厚 比 22.3 28.5 35.0 39.8 31.8 42.0 33.6 38.8 32.3 43.8 36.5 45.5 39.0 54.2 46.4 40.6 59.3 50.9 44.5 53.9 47.1 37.7 58.0 50.8 40.6 53.3 42.6 35.5 57.1 45.7 38.1 60.0 48.0 40.0 34.3 50.8 42.3 36.3 极限抗拉强度(kN) Q235/#20 229.7 297.2 367.4 418.8 520.1 443.1 550.5 638.3 761.9 722.7 863.2 1082.1 1257.7 1292.8 1503.5 1712.9 1418.4 1650.1 1880.4 1749.4 1993.9 2478.9 1886.5 2150.6 2674.8 2258.7 2809.8 2426.2 2550.5 Q345 331.1 428.5 529.8 603.8 749.9 638.9 793.7 920.3 1098.6 1042.1 1244.6 1560.2 1813.4 1864.0 2167.9 2469.8 2045.2 2379.2 2711.3 2522.4 2874.9 3574.2 2720.1 3100.9 3856.6 3256.7 4051.4 4838.3 3498.2 4353.3 5200.6 3677.4 4577.3 5469.4 6353.7 4850.0 5796.6 6735.4 Φ377x10 377 10 Φ406x10 406 10 Φ426x8 426 8 Φ426x10 426 10 Φ426x12 426 12 Φ457x8 457 8 Φ457x10 457 10 Φ457x12 457 12 Φ480x8 480 8 Φ480x10 480 10 Φ480x12 480 12 Φ480x14 480 14 Φ508x10 508 10 Φ508x12 508 12 Φ508x14 508 14 - 3 -

表2 钢管截面特性和力学性能表(续)

序号 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 规格 (mm) 标示 管径 壁厚 截面 面积 (cm2) 163.049 194.904 226.509 172.473 206.214 239.704 225.441 262.134 298.577 232.981 270.931 308.630 244.290 284.126 323.710 306.557 349.345 391.882 328.988 374.980 420.722 400.616 449.562 498.257 426.251 478.402 530.301 451.384 506.676 561.717 616.506 535.516 593.761 651.755 每米 重量 (Kg/m) 127.99 153.00 177.81 135.39 161.88 188.17 176.97 205.78 234.38 182.89 212.68 242.27 191.77 223.04 254.11 240.65 274.24 307.63 258.26 294.36 330.27 314.48 352.91 391.13 334.61 375.55 416.29 354.34 397.74 440.95 483.96 420.38 466.10 511.63 惯性矩 (cm4) 54919.07 65154.84 75150.25 65001.14 77163.53 89056.15 100813.69 116457.18 131781.42 111268.00 128574.35 145539.14 128267.04 148282.33 167921.17 186235.06 211039.81 235410.05 230167.94 260973.30 291276.42 318221.72 355350.03 391909.33 383285.16 428193.47 472455.62 455141.80 508664.77 561461.19 613537.67 600536.21 663101.16 724859.71 截面模量 (cm3) 2076.34 2463.32 2841.22 2325.62 2760.77 3186.27 3305.37 3818.27 4320.70 3532.32 4081.73 4620.29 3886.88 4493.40 5088.52 5238.68 5936.42 6621.94 6041.15 6849.69 7645.05 7828.33 8741.70 9641.07 8872.34 9911.89 10936.47 9959.34 11130.52 12285.80 13425.33 12446.35 13743.03 15023.00 回转 半径 (cm) 18.353 18.284 18.215 19.413 19.344 19.275 21.147 21.078 21.009 21.854 21.785 21.716 22.914 22.845 22.776 24.648 24.578 24.510 26.450 26.381 26.312 28.184 28.115 28.046 29.987 29.917 29.848 31.754 31.685 31.616 31.547 33.488 33.418 33.349 径 厚 比 52.9 44.1 37.8 55.9 46.6 39.9 50.8 43.6 38.1 52.5 45.0 39.4 55.0 47.1 41.3 50.8 44.4 39.5 54.4 47.6 42.3 50.8 45.2 40.7 54.0 48.0 43.2 57.1 50.8 45.7 41.5 53.6 48.3 43.9 极限抗拉强度(kN) Q235/#20 Q345 5054.5 6042.0 7021.8 5346.7 6392.6 7430.8 6988.7 8126.2 8808.0 7222.4 8398.9 9104.6 7573.0 8807.9 9549.4 9503.3 10305.7 11560.5 10198.6 11061.9 12411.3 11818.2 13262.1 14698.6 12574.4 14112.9 15643.9 13315.8 14946.9 16570.6 18186.9 15797.7 17515.9 19226.8 Φ529x10 529 10 Φ529x12 529 12 Φ529x14 529 14 Φ559x10 559 10 Φ559x12 559 12 Φ559x14 559 14 Φ610x12 610 12 Φ610x14 610 14 Φ610x16 610 16 Φ630x12 630 12 Φ630x14 630 14 Φ630x16 630 16 Φ660x12 660 12 Φ660x14 660 14 Φ660x16 660 16 Φ711x14 711 14 Φ711x16 711 16 Φ711x18 711 18 Φ762x14 762 14 Φ762x16 762 16 Φ762x18 762 18 Φ813x16 813 16 Φ813x18 813 18 Φ813x20 813 20 Φ864x16 864 16 Φ864x18 864 18 Φ864x20 864 20 Φ914x16 914 16 Φ914x18 914 18 Φ914x20 914 20 Φ914x22 914 22 Φ965x18 965 18 Φ965x20 965 20 Φ965x22 965 22 2.2 钢管的材质及工艺要求

钢管的材质为Q345B和Q235B两种(当采用20号钢无缝钢管时,其钢

- 4 -

材的力学性能按照Q235B考虑)。

钢管一般采用直缝焊接钢管,也可采用无缝钢管,不推荐采用螺旋焊管。Φ426及以下钢管的成管焊接工艺可采用电阻焊,直径大于426mm时,应采用埋弧焊管。

焊接钢管优先采用有质量保障的专业制管厂制作的成品管,也可由铁塔厂自行压制,但必须保证钢管的焊接质量和圆度等精度要求,以便于和带颈锻造法兰进行焊接。

3 插板标准图

3.1 插板类型和设计说明

插板的型式有“U”型、“C”型和“X”型3种型式,共计177个插板详图。 “C”型和“X”型分别按Q235B和Q345B两种材质钢管设计配置, “U”型插板仅按Q345B钢管设计配置。

插板的承载力按照钢管母材强度的100%、70%和50%三个级别进行设计。设计时考虑了插板、焊缝和螺栓的强度,同时考虑了结构布置和构造的合理性以及节点刚度的影响。个别插板没有达到上述设计强度时,在图上已经标明,使用时应加以注意。

每一种型号的插板对应的钢管规格和材质均是唯一的,设计人员根据钢管规格和材质选用插板型号。

3种型式插板对应的钢管规格范围及数量见表3,超过该范围的钢管插板应由使用者自行设计。

钢管插板标准图见附图1~图21所示。

- 5 -

表3 插板的配置范围及数量

钢管强度利 用率百分比 插板 类型 U C 钢管材料 强度等级 Q345B Q345B Q235B Q345B Q235B Q345B Q345B Q235B Q345B Q235B Q235B 对应钢管 规格范围 Φ114~Φ273 Φ89~Φ273 Φ89~Φ273 Φ114~Φ273 Φ114~Φ426 Φ114~Φ426 Φ89~Φ406 Φ89~Φ426 Φ114~Φ426 Φ114~Φ426 Φ89~Φ406 数量 小计 10 11 11 10 20 20 17 19 20 20 19 备注 100% X U C 70% X 50% C

3.2 插板型号命名

插板型号由7位字母或数字组成:

第一位为字母,表示插板类型,以字母“C”、“U”和“X”分别表示槽型、U型和十字型插板。

第二、三位为数字,表示插板所连的钢管的管径代号(用管径的百位数和十位数表达)。

第四、五位为数字,表示插板所连的钢管的壁厚。

第六位为字母,以S和H分别表示钢管母材材质Q235B和Q345B。 最后一位为数字,表示对应的钢管母材强度设计应力比,1表示100%、7表示70%、5表示50%。

例如: U 2 1 0 6 H 1: U型插板 D219×6钢管 管材质Q345B 管应力100% 即:U2106H1表示为Q345B材质Φ219×6钢管规格,钢管强度利用率为100%的U型插板。

- 6 -

例如: X 1 5 0 6 H 7: 十字型 Φ159×6钢管 管材质Q345B 管应力70% 即:X1505H7表示为Q345B材质Φ159×5钢管规格,钢管强度利用率为70%的“十”字型插板。

例如: C 0 8 0 4 S 5: 槽型插板 D89×4钢管 管材质Q235B 管应力50% 即:C0804S5表示为Q235B材质Φ89×4钢管规格,钢管强度利用率为50%的槽型插板。 3.3 插板使用注意事项

(1)采用插板连接时,应注意插板与连接板的强度匹配。

(2)“U”型插板的连接板厚度应取“U”型板的开口间隙减2mm。“U”型插板已按45度扩散角验算了连接板净截面强度和孔壁承压(连接板净截面强度验算时,其板宽取2L+C和B的较大值。其中C为横向螺栓最大间距,L为相应纵向螺栓的间距,B为插板的宽度)。当不满足以上计算假定时,应进行验算。

(3)“C”型插板的强度验算不考虑插板端部的卷边影响,安装时,一般要求插板的卷边侧向塔体内侧,以改善塔体的整体美观。

(4)塔体上与“X”型插板连接的十字断面连接板上螺栓的排列方式应和“X”型插板的保持一致,设计人员还应核算该十字连接板的焊缝强度。

“X”型插板的尺寸已考虑了塔体上十字连接板的焊缝高度(焊缝高度按1.2倍的连接板厚度假定)。

(5)插板标准图中的重量未含连接螺栓,连接螺栓应根据实际连接情况在施工图中考虑。