35KV变电站监测设计
摘 要
本设计以某35KV电压等级的变电站进行监测设计,该变电站安装了两台变压器。变压器型号为SCB9/35,变压器的额定容量比为25000/25000/25000。有三条负荷输出线路,分别是郊区农村用电,第一条街道线路(该街道主要用电负荷来自于居住居民用电),第二条街道线路(该街道主要用电负荷为学校和娱乐场所)。详细地设计了系统的构成,简要地研究了系统的工作过程,主要功能和特点。利用海湾模块的主要功能和特点,设计了基于海湾的电力远程监测系统主站软件的模块和主要流程,在此采用Neuron C对海湾模块进行程序编译,利用程序对参数进行计算,最后并对采集参数进行显示,对所得结果进行说明。
关键词:2次设计;海湾模块;电力参数
I
Design Of Monitoring For 35KV Substation
Abstract:The design monitoring design to a voltage level of 35KV substation, the substation installation of two transformer . Transformer model is SCB9/35, the rated capacity of the transformer is 25000/25000/25000. There are three loading output lines, including electricity in rural areas were.the first street circuit (the main electricity load of the street from the living residents), the second street (the main electricity load of the street from schools and entertainment).To design the
constitution of system in detail and understand working process,primary functions and characteristics in brief.To introduce the primary functions and features of Gulf module,making use of the Gulf module functions and features,the paper design modules and the main process based on remote monitoring system of the main power station software.The design translate and edit the program through NeuronC,then make a calculation on parameters by using the program,at last,displaythe collected parameters and make a description on the outcome.
Key words:Second design;Power Parameters
II
目录
第1章 前 言........................................................ 1 1.1选题背景 ...................................................... 1 1.2发展和现状 .................................................... 2 1.3研究内容 ...................................................... 3 1.4论文结构 ...................................................... 3 第2章 电力交流参数测试的关键算法研究............................... 4 2.1数字采样技术与实时测频算法 .................................... 4 2.1.1数字采样技术及同步采样..................................... 4 2.1.2实时测频算法和软件同步采样................................. 5 2.2实时有效值算法 ................................................ 6 2.3实时功率算法 .................................................. 7 2.4实时功率因数算法和负载特性 .................................... 9 2.5三相电路的相关功率测量 ....................................... 10 2.5.1三相四线制电路的相关功率测量.............................. 10 2.5.2三相三线制电路的相关功率测量.............................. 11 2.6本章小结 ..................................................... 12 第3章 系统的硬件平台设计.......................................... 13 3.1 设计对象 ..................................................... 13 3.2 一般监测系统硬件结构 ......................................... 13 3.2.1电流,电压互感器.......................................... 14 3.2.2采样保持器................................................ 14 3.2.3多路转换开关.............................................. 15 3.2.4 A/D转换器................................................ 15 3.3 海湾监测系统硬件设计 ......................................... 15 3.3.1电流互感器额定参数选择.................................... 15 3.3.2电压互感器额定参数选择.................................... 16 3.3.3数据处理单元.............................................. 17
III
3.3.4 LonWorks技术的主要特点有................................. 17 3.3.5 Neuron神经元芯片的硬件结构............................... 18 3.3.6 神经元芯片的结构和存储器配置 ............................. 18 3.3.7 神经元芯片的CPU及I/O功能 ............................... 20 3.3.8海湾模块.................................................. 21 3.4 硬件接线 ..................................................... 23 3.5 本章小结 ..................................................... 24 第4章 系统软件设计 ..........................................25 4.1中央监控系统操作界面和功能模块 ............................... 25 4.2 NEURON C语言介绍 .............................................. 26 4.2.1 网络变量(network variable) ............................. 26 4.2.2 I/O对象.................................................. 27 4.2.3 事件驱动 ................................................. 27 4.2.4 显示报文 ................................................. 28 4.3 软件设计 ..................................................... 28 第5章 系统的运行.................................................. 37 5.1 监测内容 ..................................................... 37 5.2 运行结果演示 ................................................. 37 结论............................................................... 40 致谢............................................................... 41 参考文献........................................................... 41
IV
第1章 前 言
1.1选题背景
变电站对电力的生产和分配起到了举足轻重的作用,学习和了解变电站的结构和运行对电力资源的可持续发展垫下了基础。随着经济的快速发展,我国电力需求迅速增长,由于产业结构调整和居民生活水平的提高,第三产业和居民生活用电比重上升,制冷制热负荷大幅度增加,使得电网规模不断扩大,高电压、大机组、长距离输电、电网互联的趋势,使电网结构越来越复杂。常规变电站的二次部分主要由四大类装置组成:继电保护、故障录波、就地监控和远动。在微机化以前,这些装置不仅功能不同,实现的原理和技术也完全不同,因而长期以来形成了不同的专业和相应的技术管理部门。近年来,开始采用微机型继电保护装置、微机型故障录波器、微机监控和微机远动装置。这些装置尽管功能不一样,其硬件配置却大体相同,除微机系统本身以外,无非是对各种模拟量的数据采集以及I/O回路,并且装置所采集的量和要控制的对象还有许多是共同的,因而显得设备重复,互联复杂。人们自然提出这样一个问题,是否应该从全局出发来考虑全微机化的变电站二次部分的优化设计,提高变电站的可控性,更多的采用远方集中控制、操作、反事故措施等,提高劳动生产率,减少人为误操作的可能,提高运行可靠性,这就是变电站综合自动化的来历。
变电站的综合自动化由电脑继电保护和监控系统组成。最明显的特征有以下四个方面:1、功能综合化。2、结构电脑化。3、操作监视屏幕化。4、运行管理智能化。变电站的总体结构采用分布式结构,引入计算机局域网(LAN)技术,将站内所有的智能化装置(IED)连接起来。变电站综合自动化应该改变常规的保护装置不能与外界通信的缺陷,取代常规的测量系统,如变送器、录波器、指针式仪表等;改变常规的操作机构,如操作盘、模拟盘、手动同期及手控无功补偿等装置;取代常规的告警、报警装置,如中央信号系统、光字牌等;取代常规的电磁式、机械式防误闭锁设备;取代常规的远动装置等。
计算机技术、通信技术、信息技术惊人的发展,为变电站综合自动化开辟了广阔的前景。变电站综合自动化系统能够大大地提高整个电网运行的安全性和经济效
1