随着数字医学的兴起,计算机技术的发展,有限元分析的研究方法在骨科领域得到广泛使用
[25-27]
。有限元
模型的建立可以使骨科生物力学的研究摆脱标本量少的困扰,并且可以通过对实验条件的控制来年解决很多在体实验无法检测的指标。有限元模型还可以对内植物的有效性进行评价,并对内植物进行有效的改进
[26,28]
。由
于多排高速螺旋CT的普及,临床上对于关节内骨折已常规采用平扫+三维重建,这就为临床进行基于有限元模型进行个性化的骨折固定方案奠定基础。
尽管有限元法分析源于真实的人体数据,能够精准模拟出骨骼的解剖,同时通过不断增加划分节点与单元的数量以及更准确地赋予单元材料属性,使模拟结果与真实情况进一步逼近,但由于无法完全模拟骨骼生理状态下的复杂受力环境及骨骼材料的各向异性,且去除了肌肉、韧带等附着软组织,故与真实情况仍存在一定误差,今后仍需要对骨骼的材料力学特性及骨骼生理受力特点进一步研究。有限元法分析不能代替实物标本的生物力学测试,两者需相互补充、借鉴。
4 参考文献 [1] Robinson CM, Hill RM, Jacobs N, et al. Adult distal humeral
metaphyseal fractures: epidemiology and results of treatment. J Orthop Trauma. 2003;17:38-47.
[2] Palvanen M, Kannus Phumeral fractures of elderly women: nationwide statistics in , Niemi S, et al. Secular trends in distal Finland between 1970 and 2007. Bone. 2010;46:1355-1358. [3] Aslam N, Willett K. Functional outcome following internal fixation of intraarticular fractures of the distal humerus (AO type C). Acta Orthop Belg. 2004;70: 118-122.
[4] Allende CA, Allende BT, Allende BL, et al. Intercondylar distal
humerus fractures-surgical treatment and results. Chir Main. 2004; 23:85-95.
[5]
Stoffel K, Cunneen S, Morgan R, et al. Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res. [6] 2008;26(6):778-784.
Pollock JW, Faber KJ, Athwal GS. Distal humerus fractures. Orthop Clin North Am. 2008;39(2):187-200.
[7] Athwal GS, Hoxie SC, Rispoli DM, et al. Precontoured parallel plate fixation of AO/OTA type C distal humerus fractures. J Orthop Trauma. 2009;23:575-580.
[8]
Theivendran K, Duggan PJ, Deshmukh SC. Surgical treatment of complex distal humeral fractures: functional outcome after internal fixation using precontoured anatomic plates. J Shoulder Elbow [9] Surg. 2010;19:524-532.
Rebuzzi E, Vascellari A, Schiavetti S. The use of parallel
pre-contoured plates in the treatment of A and C fractures of the [10] distal humerus. Musculoskelet Surg. 2010;94:9-16.
Atalar AC, Demirhan M, Salduz A, et al. [Functional results of the parallel-plate technique for complex distal humerus fractures]. [11]
Acta Orthop Traumatol Turc. 2009;43:21-27. Turkish.
Luegmair M, Timofiev E, Chirpaz-Cerbat JM. Surgical treatment of AO type C distal humeral fractures: internal fixation with a
Y-shaped reconstruction (Lambda) plate. J Shoulder Elbow Surg. 2008;17:113-120.
[12] Sanchez-Sotelo J, Torchia ME, O’Driscoll SW. Complex distal humeral fractures: internal fixation with a principle-based
parallel-plate technique. J Bone Joint Surg Am. 2007;89:961-969. [13] Shin SJ, Sohn HS, Do NH. A clinical comparison of two different double plating methods for intraarticular distal humerus fractures. J Shoulder Elbow Surg. 2010; 19:2-9.
ISSN 1673-8225 CN 21-1539/R CODEN: ZLKHAH
[14] Boyle C, Kim parison of different hip prosthesis shapes
considering micro-level bone remodeling and stress-shielding criteria using three-dimensional design space topology optimization.J Biomech. 2011. [Epub ahead of print]
[15] Trabelsi N, Yosibash Z, Wutte C, et al.Patient-specific finite
element analysis of the human femur-A double-blinded
biomechanical validation.J Biomech. 2011. [Epub ahead of print] [16] Elkins JM, Stroud NJ, Rudert MJ, et al.The capsule's contribution
to total hip construct stability - A finite element analysis.J Orthop Res. 2011. [Epub ahead of print]
[17] Ma XL, Fu X, Ma JX, et al. Shengwu Yixue Gongchengxue Zazhi.
2011;28(1):71-75.
马信龙,付鑫,马剑雄,等[18] 模型的建立Burkwalter JA. Beijing: People’s Medical Publishing House. 2001:
[J].生物医学工程学杂志. 人股骨近端空间结构重建新方法及有限元,2011,28(1):71-75.
231.
Burkwalter JA. 231.
骨科基础科学[M]. 北京: 人民卫生出版社, 2001: [19] Schuster I, Korner J, Arzdorf M, et al. Mechanical comparison in
cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma. 2008;22(2): [20] 113-120.
Liu SM, Zhou EC, Zhang Z, et al. Shandong Yiyao. 2009;49(27):
22-24.
刘士明,周恩昌,张铮,等.肘关节三维有限元模型的建立及意义[21] 东医药[J].山Wirtz DC,Schiffers N,Pandorf T,et al.Critical evaluation of known
,2009,49(27):22-24.
bone material properties to realize anisotropic FE-simulation of the proximal femur. Biomech. 2000;33(10):1325-1330.
[22] Li XL. Zhongguo Zuzhi Gongcheng Yanjiu yu Linchuang Kangfu.
2009;13(39):7619-7622.