8060A 真有效值万用表使用说明书
目录
1。概述和技术指标........................................... ..........1-1 1-1。简介................................................. ............1-3 1-2。配套设备附件......................................... ...........1 -4 1-3。规格................................................. ...........1-4 2。操作说明................................................ ..........2-1 2-1 。简介................................................. ......... 2-3 2-2 。拆开仪器............................................ ..... ..... 2-3 2-3。电池安装或更换....................................... .... ...... 2-3 2-4。更换保险丝................................................ ...... 2-5 2-5。物理特性................................................ ........ 2-6 2-6。前面板................................................ .......... 2-6 2-7 。显示................................................. .......... 2-8 2-8。信号输入限制............................................... ..... 2-9 2-9 。操作................................................. .......... 2-10 2-10。开机自检............................................ ........... 2-10 2-11。 AC / DC电压(V )..............................................2-11 2-12 。真有效值测量............................................. ..... 2-12 2-13。交流耦合交流测量.................................... ..... ..... 2-12 2-14 。波形比较和转换...................... ..... ..... ... .......... 2-13 2-15。高阻抗直流电压..................................... ...... ..... 2-14 2-16 。 AC / DC电流(A )............................................ 2-16 2-17 。电阻(Ω).............................................. ...... 2-18 2-18 。自动量程MΩ................................................ .. 2-20 2-19 。自动量程KΩ................................................ .. 2-21 2-20 。电导(S) .............................................. ..... 2-22 2-21 。二极管测试( ).............................................2-25 2-22 。相对( REL ).............................................. ... 2-27 2-23 。频率(Hz ).............................................. ..... 2-29 2-24 。分贝(dB ).............................................. ..... 2-32 2-25。伏分贝................................................. ........ 2-33 2-26 。导通性( )..............................................2-34 2-27。初步检查 –测试程序............................................. 2-36 3.应用............................................................... 3-1 3-1 。简介................................................. ...........3-3 3-2 。确定放大器带宽........................................... 3-3
3-3 。使用8060A作为一个Q表.......................................... 3-4 3-4。测量放大器级的增益与相对分贝......................................3-5 3-5。通用音频用途............................................... ..... 3-6 3-6。使用8060A来测量极低电流........ ................................ 3-7 3-7。制作dBm或dBW的测量与其他参考阻抗............................... 3-7 3-8。改变交流dB参考阻抗与直流电源.................................... 3-9 4.工作原理.............................................. .............. 4-1 4-1 。简介................................................. ........... 4-3
1
4-2 。功能说明................................................ ........ 4-3 4-3 。微电脑................................................. ......... 4-4 4-4。测量采集芯片( MAC )............................................. 4-5 4-5。 A / D转换周期............................................. ...... 4-6 4-6。电压测量........................................................... 4-8 4-7。电流测量........................................................... 4-10 4-8。电阻测量........................................................... 4-10 4-9。电导测量............................................. ............. 4-11 4-10。导通性测量........................................................ 4-12 4-11。频率测量.......................................................... 4-13 5.维护.................................................................. 5-1 5-1 。简介................................................. ............. 5-3 5-2 。服务信息................................................ .......... 5-3 5-3 。一般资料................................................ ..........5-4 5-4 。操作注意事项用于使用静电敏感器件... ......... ...................... 5-5 5-5 。拆卸和重新组装.................................................... 5-5 5-6。校准和备用保险丝存取............................ .................. 5-6 5-7。主PCB存取............................................... ......... 5-8 5-8。 LCD和PCB板微电脑解体和组装...................................... 5-9 5-9。备用保险丝更换..................................................... 5-12 5-10。清洁.............................................................. 5-12 5-11 。性能测试......................................................... 5-13 5-12 。初始程序......................................................... 5-13 5-13。微机显示测试...................................................... 5-13 5-14 。电压测试......................................................... 5-13 5-15。电阻测试.......................................................... 5-15 5-16 。通断测试......................................................... 5-16 5-17 。电导测试................................................ ........ 5-16 5-18 。电流测试................................................ ........ 5-17 5-19 。二极管测试................................................ ...... 5-18 5-20 。频率测试......................................................... 5-18 5-21 。校准调整................................................ ........ 5-19 5-22 。故障排除......................................................... 5-21 5-23 。自检............................................................. 5-21 5-24 。比例自检..........................................................5-21 5-25 。切换解码自检..................................................... 5-22 5-26 。故障排除指南..................................................... 5-23 6.可更换部件名单............................................. ..........6-1 6-1 。简介................................................. ............ 6-3 6-2 。如何获取配件........................................... .......... 6-3 6-3 。手册状态信息...................................................... 6-4 6-4 。更新工具.............................................. ........... 6-4 6-5 。服务中心.......................................................... 6-4 7.原理图............................................... ............... 7-1 7-1。 A1主PCB组件位置图................................................7-3 7-2。测试点位置图............................................... ........7-4
2
7-3。 A/D转换测量周期图................................................. 7-5 7-4。开关详细图..........................................................7-5 7-5。 A1主PCB原理图................................ ....................7-7 7-6。 A3有效值的PCB原理图...............................................7-8 安全信息
本仪器的设计和测试符合IEC出版物348。为了确保仪表的安全使用,要按照本手册中的所有安全和操作说明。如果本手册中描述的不使用仪器时,仪器的安全功能可能会失效。
2如果仪表或测试导线看起来损坏,或者如果您怀疑电表运行不正常,请不要使用仪表。 2关闭被测电路的电源切断、脱开或分断电路之前。少量的剩余电流可能是危险的。 2不要在一个端子和地之间施加超过500V有效值电压。
2高于60V DC或30V AC(有效值)时要小心。这种电压有可能会造成触电的危险。 2使用探头时,保持你的手指握在探针护指装置的后面。 2断开公共测试导线之前,先断开测试导线。 本手册中使用下列国际符号:
——说明书中重要安全信息 ——交流 ——直流 ——二极管测试 ——地 ——保险丝
——表示接线端子可能存在危险电压
——电池
1-1。简介
福禄克型号8060A是一款手持式,基于微机的4?位 万用表是非常适合使用在野外、实验室、工厂、家庭。该8060A的所有功能,已成为公认的标准功能手持万用表,以及一些新的之前还没有在手持万用表被提供的功能。新功能有以下内容: 2真有效值测量交流信号高达100千赫。 2测量频率高达200 kHz。
2以dBm为单位的电压测量引用到600W或以dB相对于操作者选择的基准电压。 2电阻测量可达300MΩ。
2能够存储任何输入信号的偏移或相对的参考值。 其他功能还包括: 2功能:
所有标准数字万用表的测量功能,如交流和直流电压,交流和直流电流,以及电阻,电导,导通性和二极管测试。 2范围: 前置零抑制。 自动极性。 超量程指示。
防止瞬态高达1500V峰值的过载。
双斜率积分A / D转换,以确保无噪声的测量。
自动量程MΩ电阻范围(300MΩ),以及四个固定电阻范围从200Ω到200KΩ。
3
2操作方便: 4?位液晶显示器。
软件控制的自我测试程序,内部电路和操作的快速验证。 2功率:
一般一节9V碱性电池(NEDA 1604)可以连续运行170小时以上。
电池电压过低自动检测和显示。低电压(约低于20%电压)BT报警符号显示。 全套的附件线可提升8060A的功能。
1-2。设备附件
随您的真有效值万用表附件如下: 2电池
2数字万用表附件清单 2使用说明书 2操作指南卡 2保修单 2合格证 2测试线
1-3。产品规格
8060A规格性能指标如下: 电气
以下规格性能指标是根据一年的校准周期,18?28°C(64至82°F)的工作温度和相对湿度不超过80%。 直流电压
量程 分辨率 精度±(读数%+几个字) 200 mV 0 .01 mV 0.04% + 2 2V 0 .1 mV 0.04% + 2 20V 1 mV 0.05% + 2 200V 10 mV 0.05% + 2 1000V 100 mV 0.05% + 2
响应时间.............................1秒最大,选定范围内额定精度。 输入阻抗.............................10MΩ
常模噪声抑制.........................>60分贝在50 Hz或60 Hz
共模噪声抑制... ..................> 120分贝直流,>90 dB在50 Hz和60 Hz(1KΩ不平衡) 过载保护............................. 1000V DC或AC峰值连续的不超过20秒,在200 mV和2V范围最高300V DC或RMS。
直流电压,高阻抗模式所有规格都是相同的直流电压模式,下列量程除外(只有200 mV和2V范围可供选择):
量程 分辨率 精度±(读数%+几个字) 200 mV 0 .01 mV 0.05% + 2 2V 0 .1 mV 0.05% + 2 输入阻抗...........................>1000 MΩ,一般10,000 MΩ
过载保护........................300V DC或RMS连续20秒最大300V到1000V DC或AC峰值。 直流电压,分贝模式
测量单位为dBm参考600Ω或相对分贝制成。所有规格都是一样的直流电压,除了以下几点:
4
动态范围.............................采用全0.01分贝分辨率,99.79分贝。总的规定的动态范围是136.22分贝(160 μV至1000V)。
分辨率和精度..........取决于线性直流计数(计数指在直流电压独立的小数点显示 - 见下表)。 准确性
dBm的参考 600Ω范围 公差 -74 ~ -56 (160 mV ~ 1.27 mV) 200 mV 1 dB -55.6 ~ -37.6(1.28 mV ~ 10.23 mV) 200 mV 0.2 dB -37.58 ~ -31.77(10.24 mV ~ 19.99 mV) 200 mV 0.04 dB -31.76 ~ -11.76(20 mV ~ 199.99 mV) 200 mV 0.04 dB -11.76 ~ 8.24(0.2V ~ 1.9999V) 2V 0.04 dB 8.24 ~ 28.24(2.000V ~ 19.999V) 20V 0.04 dB 28.24 ~ 48.24(20.00V ~ 199.99V) 200V 0.04 dB 48.24 ~ 62.22(200.0V ~ 1000V) 1000V 0.04 dB 线性计数 分辨率 精度 19.999 ~ 1024 0.01 dB 0.04 dB 1023 ~ 128 0.1 dB 0.2 dB 127 ~ 16 1 dB 1 dB 交流电压(真有效值,AC耦合)
范围..................200毫伏,2V,20V,200V,750V 准确度*.............±(a%3读数+字数)。请参阅下表: 输入电压 分辨率 量程
未指定 未指定
*未指定的输入信号范围<10%。
**对于介于10%和范围15%的输入电压,增加一个额外的140计数。 输入阻抗........................10MΩ<分流100 pF的