石家庄DT测试报告(模板)(4)

2020-06-08 09:42

5、F-FCH FER分析

F-FCH FER Statistics1009080706050403020100(-INF, 1](1, 2]4.14.1(2, 3]0(3, 5]0(5, +INF)91.8Cumulative Percentage91.895.9100100100

6、Aggregate Ec/Io分析

Aggregate Ec/Io Statistics1009080706050403020100(+INF, -6)[-6, -8)7.142.68[-8, -10)1.34[-10, -12)0[-12, -15)0[-15, -INF)88.84Cumulative Percentage95.9898.6610010010088.84

(四)地下室测试指标分析

1、地下室结构图

驿家365地下室结构如下图所示。

15

电梯电梯 2、测量路径图

测量路径如下图所示。

16

3、Tx_Power分析

TX Power Statistics1009080706050403020100(-INF, -20](-20, -10]1.320(-10, 3]0(3, 13]0(13, 23]0(23, +INF)98.68Cumulative Percentage98.68100100100100100

4、Rx_Power分析

RX Power Statistics1009080706050403020100(+INF, -65)[-65, -75)2.29[-75, -85)0[-85, -95)0[-95, -105)0[-105, -INF)16.2281.49Cumulative Percentage97.7181.49100100100100

17

5、F-FCH FER分析

F-FCH FER Statistics100Cumulative Percentage100908070605040302010100100100100100000(2, 3](3, 5]0(5, +INF)0(-INF, 1](1, 2]

6、Aggregate Ec/Io分析

Aggregate Ec/Io Statistics100Cumulative Percentage100908070605040302010100100100100100100000[-8, -10)[-10, -12)0[-12, -15)0[-15, -INF)0(+INF, -6)[-6, -8)

(五) 问题区域分析

1、路测分析

路测数据分析时,发现在09:11:08:337到09:12:24:857时间段内(即经纬度在Lon:+114:33:13,Lat:+38:00:12附近)发生了12次软切换,这12次切换虽未造成调话,但对信道资源占用过大。通过指令表分析可知,在此期间始终有PN偏置

18

为300的导频存在,且该导频的Ec/Io值在-9.5~-5dB之间,怀疑是软切换参数设置出现了问题。查看设置参数分别为T_ADD=24、T_DROP=30、T_TDROP=5等,均符合设置要求。

解决方法:可考虑适当增加主覆盖区的天线发射功率,减小旁边基站朝向本区域小区的发射功率或增加下倾角。

2、地下室覆盖测试分析

驿家365地下室布有CDMA直放站,测试结果如下图所示:

由图可知,驿家365地下室覆盖情况非常好,其导频始终只有一个PN偏置值为147的导频,该导频的Ec/Io值始终大于-10dB,主要原因是地下停车场安装了超过15幅吸顶天线。

该区域无需再优化。

3、电梯覆盖测试分析

对驿家365电梯进行测试时,发现很多楼层信号较弱,覆盖率只有46.2%,测试结果如下图所示:

19


石家庄DT测试报告(模板)(4).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!