目 录
引
言???????????????????????????????2 1.矿井安全监控系统安装设计依据 ........................................................................... 2 2.中心站和分站的设置 ................................................................................................ 2 2.1中心站设置。...................................................................................................... 2 2.2分站设置.............................................................................................................. 3 3. KJ90各传感器的安装位置和规范要求 ................................................................. 3 3.1瓦斯传感器的设置。 ........................................................................................ 3 3.1.1回采工作面瓦斯传感器安装....................................................................... 3 3.1.2掘进工作面瓦斯传感器安装....................................................................... 4 长壁采煤工作面瓦斯传感器的安装...................................................................... 5 3.2风速传感器.......................................................................................................... 8 3.3负压传感器.......................................................................................................... 8 3.4风流压力传感器 ................................................................................................. 8 3.5粉尘传感器.......................................................................................................... 8 3.6感应式馈电传感器 ............................................................................................. 9 3.7风门开闭传感器 ................................................................................................. 9 3.8机电设备开停传感器 ....................................................................................... 10 3.9.温度传感器........................................................................................................ 10 3.10一氧化碳传感器 ............................................................................................. 11 4.安装的技术参数要求 .............................................................................................. 11 5.安装过程中的防干扰措施 ...................................................................................... 12 5.1地面中心站抗干扰措施 ................................................................................... 12 5.1.1接地............................................................................................................... 12 5.1.2缩短连线....................................................................................................... 12 5.1.3耦合器隔离................................................................................................... 12 5.2模系统的抗干扰措施 ....................................................................................... 13 5.2.1减少误码....................................................................................................... 13 5.2.2传输速率可变............................................................................................... 13 5.2.3解调与调制分开........................................................................................... 13 5.3井下分站抗干扰措施 ....................................................................................... 14 5.3.1接地问题....................................................................................................... 14 5.3.2去耦............................................................................................................... 14 5.3.3反射干扰的预防........................................................................................... 14 5.3.4数字电路与模拟电路分开........................................................................... 14 6.矿井安全管理制度 .................................................................................................. 15 总 结……………………………………………………………………………15 参考文献……………………………………………………………………………..15
矿井安全监控系统安装设计
摘要:介绍了煤矿监控系统的整体设计方案。详细说明了分站及传感器设计的思路、原理和方法。该系统经应用,性能良好。
关键词:煤矿安全监控系统;断电控制器;主机;分站;甲烷传感器 Abstract:Coal Mine Monitoring System introduces the overall design. Detailed description of the sub-station and sensor design ideas, principles and methods.
The system has been applied with good performance.
Key words:Coal Mine Safety Monitoring System;Power controller;Host Computer;Sub-station;Methane Sensor
引言
随着网络技术的不断发展和国家对煤矿安全生产的重视,煤矿的安全生产显得越来越重要。从2001年~2003年国家投入40亿国债资金用于煤矿安全生产技术改造,全国大多数煤矿都实行了安全监测系统联网。矿井监测监控系统的装备大大提高了矿井安全生产水平和安全生产管理效率,同时也为该技术的正确选择、使用、维护和企业安全生产信息化管理提出了更高的要求。
1.矿井安全监控系统安装设计依据
1、《煤炭工业小型矿井设计规范》 2、《煤矿安全规程》[2006]版
3、《矿井安全监控系统与瓦斯检查》[2003]年
4、国家其它有关煤炭工业建设的技术、经济政策和法律、法规 5、煤矿提供的相关资料和设计要求
2.中心站和分站的设置
2.1中心站设置。
电源由10/0.4kV终端式变电所两回的0.4kV母线段供电。监控机房设有一部直通矿井调度室电话。安全监测监控总站是KJ90NA型矿井监控系统的核心,融计算机网络系统、监测监控系统、工业电视系统、人员监测系统及程控调度通信系统于一体,是整个矿井网络信息管理系统的核心部分,主要监测监控矿井上下各类安全及生产参数及电力参数,汇接管理多个安全与生产环节子系统,该系统具有数据处理、报表、曲线、图形等屏幕显示、打印和绘图、实时数据存储和各种统计数据存储处理、参数超限报警、控制等多种功能,系统能报警和记录并
自动切除故障支路。系统设备具有完善的故障闭锁功能,当与闭锁有关的设备未投入正常运行或故障时能切断与之有关设备的电源并闭锁。系统具有可靠的避雷保护措施。
2.2分站设置
本设计设有4个分站,位置分别设置在:
1、在+600水平设置一台大分站(八模八开)以满足+600水平的主水仓,中央变电所,皮带运输机及煤仓等实时监控。安装传感器有:
a.主水仓:液位传感器2台(主副水仓各一台),设备开停传感器3台(3台电动机各一台)。
b.中央变电所:瓦斯传感器1台,温度传感器1台,烟雾传感器1台,设备开停传感器2台(2条10kv入井电源总开关各一台)
c.皮带运输机:设备开停传感器2台,温度传感器1台,烟雾传感器1台,瓦斯传感器2台(机头即煤仓上部1台,机尾即采区溜煤眼下部1台)。 2、在+800水平设置一台大分站(八模八开)以满足+800水平的采区,掘进工作面及风门等实时监控。
3.KJ90各传感器的安装位置和规范要求
煤矿必须严格执行《煤矿安全规程》。本安全设施设计按有煤尘无爆炸性和煤层属自然煤层设计。矿井正常生产期间布置1个回采工作面和2个掘进工作面。根据各监测地点及监测内容表,即可确定所需的传感器种类和数量。同时根据各传感器在运行期间的故障,考察一定的备用量,各传感器的备用系数为:瓦斯传感器:35%;负压传感器:25%;其它模拟传感器:20%;开关类传感器:20%;控制类传感器:20%。一体化主机采用双机热备份。
3.1瓦斯传感器的设置。
瓦斯传感器应设置在巷道上方,传感器应垂直悬挂距顶板,不得大于300MM,距巷道侧壁不得小于200M。安装地点不得有滴水,无杂物,便于观察的地方。
3.1.1回采工作面瓦斯传感器安装
回风顺槽设置有瓦斯传感器3台(上隅角一台,回风顺槽近工作面10米范围内一台、距回风巷10~15米范围内一台),采煤工作面运输巷设置瓦斯传感器
1台、工作面瓦斯传感器T1设在回风顺槽距采面≤10m处,监测采面瓦斯。瓦斯传感器T3设在运输顺槽距采面≤10m处;距离巷道顶部250mm。采煤工作面长度大于1000m时,必须在回风巷中部增设甲烷传感器。工作面运输顺槽设粉尘传感器一台。回采工作面瓦斯传感器布置详见图1。
T1--回采工作面风流中的瓦斯传感器 T2--回采工作面回风流中的瓦斯传感器 T3--回采工作面进风流中的瓦斯传感器 3.1.2 掘进工作面瓦斯传感器安装
运输巷掘进工作面设置瓦斯传感器1台,回风流内设置瓦斯传感器1台;回风巷掘进工作面设置瓦斯传感器1台、粉尘传感器1台,回风流内设置瓦斯传感器。掘进工作面长度大于1000m时,必须在掘进巷道中部增设甲烷传感器。掘进工作面瓦斯传感器布置详见图2。
图2
图 例掘进巷道T110-15mT2 污风流方向 新鲜风流方向
T1T2
掘进工作面风流中的瓦斯传感器 掘进工作面回风流中的瓦斯传感器局部通风机>10m≤5m
3.1.3长壁采煤工作面瓦斯传感器的安装
U型通风方式在上隅角设置甲烷传感器T0,工作面设置甲烷传感器T1,
工作面回风巷设置甲烷传感器T2;若煤与瓦斯突出矿井的甲烷传感器T1不能控制采煤工作面进风巷内全部非本质安全型电气设备,则在进风巷设置甲烷传感器T3;采煤工作面采用串联通风时,被串工作面的进风巷设置甲烷传感器T4,如图3a所示。Z型、Y型、H型、W型和双Z型通风方式的采煤工作面甲烷传感器的设置参照上述规定执行,如图3b-f所示。