连接Brocade san switch 或者san switch module使用 Brocade 8GB

2019-03-03 17:40

连接Brocade san switch 或者san switch module使用 Brocade 8GB SFP无法正常通信的问题,需要更改交换机端口的Fill word。【Brocade san switch只能使用Brocade 8GB SFP】

详细的解决方法:

1.检查san switch的端口 fill word

cli:portcfgshow

Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+-- Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Fill Word 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

0- Fillword set to IDLE (This is how it should be set.) 1- Fillword set to ARB

2.在端口上开启IDLE(enable IDLE on ports) cli:portcfgfillword 15 0

portcfgfillword x(x is the port number) 0

Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+-- Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Fill Word 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3.关闭端口(disable port) cli:portdisable 0 0

4.开启端口(enable port) cli:portenable 0 0

5.检查san switch 和端口的状态 switchshow


连接Brocade san switch 或者san switch module使用 Brocade 8GB.doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!