1056Na-钠表中文手册(2)

2019-03-06 07:39

Chempure 1056钠离子分析仪安装使用说明书 目录 ++ 3.3 工厂电气连接................................................................................................................................17 3.3.1 电源板接线.........................................................................................................................18 3.3.2 CPU主板接线......................................................................................................................19 3.3.3 继电器板接线.....................................................................................................................20 3.3.4 信号器板接线.....................................................................................................................21 4. 显示与操作显示与操作..............................................................................................................................................22 4.1 LCD显示和键盘............................................................................................................................22 4.2 编程................................................................................................................................................23 4.2.1主菜单..................................................................................................................................24 4.2.1.1 标定与校准............................................................................................................25 4.2.1.2 输出保持................................................................................................................27 4.2.1.3 程序设定................................................................................................................28 4.2.1.4 显示设置................................................................................................................34 4.2.1.5 仪器记录................................................................................................................35 5. 仪器标定和校准仪器标定和校准......................................................................................................................................37 5.1 开机................................................................................................................................................37 5.2 标定................................................................................................................................................37 5.2.1标定液标定..........................................................................................................................37 5.2.1.1 碱化气体-氨气.......................................................................................................38 5.2.1.2 准备标定液............................................................................................................38 5.2.1.3 标定过程................................................................................................................39 5.2.2 样品标定.............................................................................................................................42 5.2.3 温度标定.............................................................................................................................44 Chempure 1056钠离子分析仪安装使用说明书 目录 ++ 5.2.4 输出电流校准.....................................................................................................................46 5.2.5 电气标定.............................................................................................................................47 5.2.5.1 需要的设备............................................................................................................47 5.2.5.2 准备........................................................................................................................47 5.2.5.3 校准过程................................................................................................................47 6. 维护..........................................................................................................................................................49 6.1 停机和启动操作............................................................................................................................49 6.2 日常维护........................................................................................................................................49 6.3 电极维护........................................................................................................................................50 6.3.1 钠电极维护.........................................................................................................................50 6.3.2 参比电极维护.....................................................................................................................51 附录A:备品备件.......................................................................................................................................52 附录B:标定溶液的配置...........................................................................................................................53

附录C:二异丙胺的安全规范...................................................................................................................54

附录D:氟化氢的安全规范.......................................................................................................................57

Chempure 1056钠离子分析仪安装使用说明书 概述 ++1. 1.1 简介和技术规格 ? ? ? 概 述 专业的钠敏测量电极 —— 性能稳定,使用寿命长; 维护工作量低 —— 定期添加碱化液和参比电极填充液,定期更换钠敏电极; 320 × 240大屏幕液晶显示屏 —— 中、英文菜单显示,操作方便; ? 测量稳定性高 —— 带温度补偿; ? 维护费用低 —— 降低运行成本; ? 具有强大的数据存储功能 —— 可保存? 盘式安装或落地安装(选择项)—— ? 完善的设计结构 —— 采用干、湿盘分体设? 预备试剂和标定液 —— 用户无需配制以从工厂买到这些试剂和标定液。

应用 Chempure++ 1056钠离子分析仪可以检给水和蒸汽冷凝水中钠离子的含量。 蒸汽中的钠离子对汽轮机叶片和工艺管道化学控制是非常重要的。 根据钠离子分析仪安装位置的不同,仪器分为蒸汽钠离子分析仪和阳床钠离子分析仪 Chempure++ 1056钠离子分析仪整体为箱部分为电气部分,即干盘。下面部分为流路系统和化 性能优势 无论是阳床钠离子分析仪还是蒸汽钠离子分析仪,在水样入量,保证水样碱化处理过程的均匀、恒定,从而 阳床钠离子分析仪使用纯氨气作为碱化护装置(液位开关),目的是当水样断流时磁阀还可以确保在氨气钢瓶减压阀故障的情况下, Chempure++ 1056钠离子分析仪的日常维护或纯氨气。此外,为了保证测量精度,建议每月 1年的历史数据和操作记录(操作记录多达 计,结构精巧,水电分开,确保整机安全工作;的试剂,工厂已将试剂作了标准化的处超纯水中微量钠离子的浓度,广泛应用于电厂监测锅炉具有很强的腐蚀作用,所以,连续监测火式结构,外壳为金属壳体,由上、下两部学模块,即湿盘。

口都设有稳压装置,目的是稳定流

消除水样入口流量、压力变化对测量的理气源。在水样入口环节(溢流杯),设有自动关闭氨气电磁阀,保证氨气不会泄漏也不会发生氨气泄漏的状况。 非常简单,定期添加参比电极填充液、二异丙胺试剂

对分析仪进行一次标定。 1 400条); 两种形式。上面

。 断流检测保

此外,该电使用方便;复杂理,用户可测力发电厂的

分组成,影响处,。 Chempure 1056钠离子分析仪安装使用说明书 概述 ++技术规格 变送器 测量范围 最小分辨率 输出精度 供电电源 功率消耗 :0.00~9.36pNa,0.01ug/L~23.0g/L,-1000~1000mV :0.01pNa,0.01μg/L,0.1mV :± 1%F.S :110/220VAC,50/60Hz :8W 仪器显示 语言选择 电流输出 报警输出 数据存储 数据存储功能 整机 测量范围 准 确 度 读数响应时间 温度传感器 测温范围 测温精度 温度分辨率 温度补偿范围 校准方法 外形尺寸 开孔尺寸 重 量 样品要求 温 度 压 力 流 量 水样允许固体成份 320×240点阵液晶 中文,英语 2个隔离的0~10mA,0~20mA或4~20mA,输出最分别定义为钠离子浓度和过程温度 2个220VAC 3A或24VDC 5A,其可以分别定义高温报警、低温报警或断流报警(报警值可编程注:继电器是可以重复选择的,如果两个报警选择任何一个报警启动,该继电器都动作。 可设置自动记录历史数据、历史事件和校准记录最少可保存1年的历史数据和操作记录(操作记录多1.00~8.00pNa,0.23ug/L~2300mg/L ± 0.03pNa或±0.5ug/L,取较大数值(在校准温度的在25℃时2分钟内达到变化的90% Pt 1000 0.0~99.9℃ ± 0.5℃ 0.1℃ 0.1~60.0℃(手动或自动) 样品校准、标准溶液校准 盘装仪表:452mm × 932mm × 190mm(宽× 高落地仪表:452mm × 1432mm × 190mm(宽 × 410mm × 890mm(盘装仪表) 20公斤(不包括试剂) 5~50℃ 50~300KPa 6~40升/小时 :≤5微米(不允许有胶状物、无油脂) 2 大负载电阻浓度上限报警、调节) 了同一个继电器, 达400条)±10℃以内)× 深) × 深)(选择项)800?,其可以度下限报警、那么,其中 ::: :浓 :: :: :::::: 高::::::: Chempure 1056钠离子分析仪安装使用说明书 概述 ++环境条件 环境温度 环境湿度 储运温度 :5~45℃ :≤90%RH(无冷凝) :-25~55℃(不含电极,电极要高于0℃) :OD 6mm :OD 6mm(阳床钠离子分析仪:ID 16mm :PG9 :PG9 :PG9

3 接口要求 水样入口 氨气入口 水样排放 电源接口 )模拟信号接口 报警信号接口


1056Na-钠表中文手册(2).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!

下一篇:冲刺高考《自信造就成功》励志演讲稿

相关阅读
本类排行
× 注册会员免费下载(下载后可以自由复制和排版)

马上注册会员

注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信: QQ: