深圳发展银行宁波分行 机房建设工程设计方案
深圳发展银行宁波分行 电子信息系统机房建设工程
一阶段设计
深圳发展银行宁波分行 机房建设工程设计方案
目 录
第一节、总 述 ·········································································· 1
1.1系统概述 ........................................................................................................................... 1 1.2 设计原则 ........................................................................................................................... 1 1.2.1科学性和系统性 ......................................................................................................... 1 1.2.2 经济型和适用性 ........................................................................................................ 1 1.2.3 美观性和舒适性 ........................................................................................................ 2 1.3 设计标准 ........................................................................................................................... 2 1.3.1遵循设计标准 ............................................................................................................. 2 1.3.2参考设计标准 ............................................................................................................. 2 1.4 设计范围 ........................................................................................................................... 3 1.5技术指标 ............................................................................................................................ 4 1.5.1环境要求 ..................................................................................................................... 4 1.5.2供配电要求 ................................................................................................................. 4 1.5.3照明要求 ..................................................................................................................... 5 1.5.4地线要求 ..................................................................................................................... 5 1.5.5综合布线要求 ............................................................................................................. 5 1.5.6结构装修要求 ............................................................................................................. 5
第二节 系统设计 ······································································· 7
2.1平面功能布置设计 ............................................................................................................ 7 2.1.1区域功能分析设计 ..................................................................................................... 7 2.1.2设计总结 ..................................................................................................................... 7 2.2结构装饰系统设计 ............................................................................................................ 7 2.2.1吊顶装璜工程 ............................................................................................................. 8 2.2.2墙体制作工程 ............................................................................................................. 8 2.2.3地面工程 ..................................................................................................................... 8 2.2.4门窗工程 ..................................................................................................................... 8 2.2.5隐蔽部分工程 ............................................................................................................. 9 2.2.6加固部分工程 ............................................................................................................. 9 2.3 动力配电系统设计 ........................................................................................................... 9 2.3.1总体设计 ..................................................................................................................... 9 2.3.2强电管道设计 ............................................................................................................. 9 2.3.3机房区域照明设计 ................................................................................................... 10
深圳发展银行宁波分行 机房建设工程设计方案
2.4 机房PDS综合布线系统设计 ........................................................................................ 10 2.5 机房空调、新风系统设计 ............................................................................................ 11 2.5.1中心机房区精密空调设计 ....................................................................................... 11 2.5.2精密空调区域保温 ................................................................................................... 11 2.5.3机房区防漏水部分 ................................................................................................... 12 2.5.4中心机房区新风设计 ............................................................................................... 12 2.6 UPS不间断电源系统设计 .............................................................................................. 12 2.6.1UPS系统简介............................................................................................................ 12 2.6.2系统设计 ................................................................................................................... 13 2.7 防雷、接地系统设计 ..................................................................................................... 13 2.7.1机房地线系统 ........................................................................................................... 13 2.7.2设计依据 ................................................................................................................... 13 2.7.3接地系统 ................................................................................................................... 14 2.7.4等电位连接 ............................................................................................................... 14 2.7.5防直击雷措施 ........................................................................................................... 15 2.7.6强电防浪涌保护系统 ............................................................................................... 15 2.7.7弱电防浪涌保护系统 ............................................................................................... 15 2.8 机房安防系统设计 ......................................................................................................... 15 2.9 机房环境集中监控系统设计 ......................................................................................... 16 2.9.1需求分析 ................................................................................................................... 16 2.9.2系统设计简述 ........................................................................................................... 16 2.9.3主要功能 ................................................................................................................... 16 2.10 静电释放系统设计 ....................................................................................................... 17 2.11 气体消防系统设计 ....................................................................................................... 17 2.11.1系统设计说明 ......................................................................................................... 17 2.11.2灭火系统简介 ......................................................................................................... 18 2.11.3灭火系统动作程序 ................................................................................................. 19 2.11.5灭火系统使用方法 ................................................................................................. 20 2.12 机房其它辅助系统设计及机房灾害防护 ................................................................... 21 2.12.1网络服务器机柜 ..................................................................................................... 21 2.12.2机房灾害防护 ......................................................................................................... 21
深圳发展银行宁波分行 机房建设工程设计方案
第一节、总 述
1.1系统概述
计算机机房工程是一个集多系统的系统集成工程,从某种角度可视为电气通讯工程和装修工程完美的结合工程。电气通讯是工程的核心,装修是电气性能达标的保证工程,共同造就一个和先进现代通讯机房相匹配的运行环境。它主要包括:机房结构装饰系统,机房动力配电系统、机房UPS不间断电源系统、机房防雷接地系统、机房专用精密空调、新风系统、机房PDS结构化综合布线系统、机房专用气体消防系统、机房安防门禁、视频监控系统、机房动力环境集中监控系统等的综合集成工程。经我公司技术人员认真分析研究各项因素后,现提出本设计方案以供贵单位领导及信息中心技术人员参考、定夺,使新建的机房系统符合国家机房相关标准及目前的实际应用需求,并有适当的系统扩展余量。使深圳发展银行宁波分行建成后的中心机房,成为充分体现现代化、信息化综合管理的象征。
1.2 设计原则 1.2.1科学性和系统性
计算机机房的设计和工程实施首先要体现科学性,即要严格按照国家现有的规范、标准来进行综合设计(或部分参照国际标准设计,主要指我国现有规范不足部分);其次计算机机房的设计更要从多元系统性的角度来考虑。现代化计算机机房不只是一个简单计算机设备摆放的场所,而是由动力供配电系统、综合监控系统、综合布线系统、精密空调系统、气体消防灭火系统、专用接地系统、结构装饰系统、防浪涌保护系统、安保门禁系统、BA系统等十多个系统组成的综合系统工程,各系统均不是相互隔离的,而是有密切的关联。良好的施工需要经验丰富的现场工程师,认真把关的材料采购员和出色的施工人员配合。为了确保计算机主机、网络等设备的稳定、可靠、安全运行,一定要综合考虑计算机机房各单系统之间运行的系统性。
1.2.2 经济型和适用性
深圳发展银行宁波分行机房功能、区域及性能指标的确定必须根据现有计算机网络系统目前和今后五年内各主机设备对综合环境的要求,并有适当的超前。同时,深圳发展银行宁波分行机房系统工程应避免由于过高的设置机房综合环境、技术参数而带来的
深圳发展银行宁波分行 机房建设工程设计方案
设备、设施、规模和档次不必要的提高而造成项目投资总额过大。我公司设计方案是根据深圳发展银行宁波分行在今后几年内对业务发展的要求,在满足网络通讯发展的前提下作五年规划设计的。
1.2.3 美观性和舒适性
现代化计算机机房作为一个企业信息、业务、管理的汇集中心,电子技术和网络管理运作的窗口,其设计在满足先进、可靠、安全、适用、系统性的前提下,作为综合数据的汇集点,开发管理人员的工作场所,还需要满足一定的美观性和舒适性。因此,我公司对于深圳发展银行宁波分行提供建设的机房现有使用面积进行了区域划分明确,从科学、适用的角度以达到突出重点区域、确保使用功能齐备、总体机房区域视野开阔、便于观察管理的目的;其次合理的配置和使用现代化的机房专用装饰材料,使待建后的计算机机房达到美观、舒适、赏心悦目的效果。
从上述设计思想、方针出发,我公司相信建成后的深圳发展银行宁波分行机房将充分地体现深圳发展银行宁波分行信息化技术的综合管理水平。
1.3 设计标准 1.3.1遵循设计标准
GB9361-88《计算站场地安全要求》 ? GB2887-89《计算机场地技术条件》 ? GB50174-93《电子计算机机房设计规范》 ? GB/T2887-2000《电子计算机场地通用规范》 ? GB6650-86《计算机机房用活动地板技术条件》
? SJ/T10796-1996《计算机机房用抗静电活动地板技术条件》
1.3.2参考设计标准
? 《工业与民用供电系统设计规范》(GBJ52-82) ? 《低压配电装置及线路设计规范》(GBJ54-83) ? 《电气装置安装工程施工及验收规范》(GBJ32-82) ? 《电气装置安装工程接地装置施工及验收规范》(50169-92) ? 《低压配电设计规范》(GB50054-95) ? 《不间断电源设备》