7.2电气设备选择的一般条件 ........................................ 28 7.3相关电气设备选择和校验 ........................................ 28
7.3.1电流互感器选择 ........................................... 29 7.3.2电压互感器选择 ........................................... 30 7.3.3断路器选择 ............................................... 31 7.3.4隔离开关的选择 ........................................... 33 7.3.5避雷器和熔断器的选择 ..................................... 35 7.3.6母线的选择 ............................................... 35
8 配电装置的设计 .................................................... 38
8.1概述 .......................................................... 38 8.2 配电装置的设计 ................................................ 39 9 防雷和接地保护装置的设计 .......................................... 40
9.1防雷保护 ...................................................... 40 9.2接地装置 ...................................................... 41 结论 ................................................................. 41 谢辞 ................................................................. 42 参 考 文 献 .......................................................... 43 附录1:电气主接线图
附录2: 主变保护原理接线图 附录3: 二次回路原理图
某新区110KV变电站电气部分初步设计
摘要:
变电站作为电力系统中的重要组成部分,直接影响整个电力系统的安全与经济运行。本论文设计的中间变电站,不仅增强了当地电网的网络结构,而且为当地的工农业生产提供了足够的电能,从而达到使本地区电网安全、可靠、经济运行的目的。
本论文通过对原始资料的分析及根据变电站的总负荷选择主变压器,同时根据主接线的经济可靠、运行灵活的要求,选择了两种主接线方案,并且进行技术比较,淘汰较差的方案,确定了变电站的电气主接线方案。
其次进行短路电流计算,从三相短路计算中得到当短路发生在各自电压等级的母线时,其短路稳态电流和冲击电流的值。再根据计算结果及电压等级的额定电压和最大持续工作电流进行主要电气设备选择及校验(包括断路器、隔离开关、电流互感器、电压互感器等),其中也包括智能设备的选择和校验。 最后,并绘制了电气主接线图、主变保护原理接线图、二次回路原理图。
关键词:
电气主接线设计;短路电流计算;电气设备选择;智能设备选择
1
Abstract:
As an important part of power system, substation directly affects the safety and economic operation of the entire power system. In this thesis, the middle of the substation, not only enhances the local power grid network structure, but also for the local industrial and agricultural production provides enough power, so that the regional power grid so as to achieve safe, reliable and economic operation purposes.
This paper selected the main transformer through the analysis of raw data and
based on total load of the substation. This paper selected two main wiring under both economy and reliability .Compare from flexible operation requirements, the substation give up the program less determine and mark sure the main electrical substation connection program.
Second, go ahead calculation of short-circuit current, its steady-state current and the impact of short-circuit current value obtained from the three-phase short circuit calculation ,when the short occur in the respective voltage level of the bus .According to the results and the voltage level of the rated voltage and maximum continuous operating current go ahead the main electrical equipment selection and validation (including circuit breakers, isolating switches, current transformers, voltage transformers, etc.), also including the choice of smart devices and school experience.
Finally, draw the main electrical wiring diagram, electrical general layout map,
lightning protection and other related design layout plan drawings.
Keywords:
Main electrical wiring design; short-circuit current calculation; electrical equipment selection; intelligent device selection
2
1 引言
110KV降压变电站作为一个中间变电站,将发电厂与负荷中心连接起来,起到了交换功率或长距离输电线路分段的作用,它的投入使用给我们带来了极大的便利。
在我国,电力工业正迅速发展,因此对发电厂(变电所)的设计也提出了更高的要求,而在发电厂(变电所)的设计组成中,电气设计是一重要组成部分,需要我们认真地研究对待。
随着高新技术的发展和应用,对电能质量和供电可靠提出了新的要求,高压、超高压变电站的控制和保护系统必须适应这种新形势,因此,改善电网结构,提高供电能力与可靠性以及综合自动化程度,以满足日益增长的社会需求是电力企业的首要目标。在我国近几年发展迅速,产品的更新换代及定型也越来越快。从这几年应用和实践看,数字化变电站给变电站设计安装、调试和运行、维护、管理等方面都带来了一系列自动化技术的变革。但是,目前国内数字化变电站的运用还不够成熟,因此,我们应该努力朝着数字化变电站[1],以及智能电网[2]方向发展。近年来110kV变电站的建设迅猛发展。科学的变电站设计方案能够提升配电网的供电能力和适应性,降低配电网损耗和供电成本,减少电力设施占地资源,体现“增容、升压、换代、优化通道”的技术改造思路。同时可以增加系统的可靠性,节约占地面积,使变电站的配置达到最佳,不断提高经济效益和社会效益。为了保障我国经济的高速发展,以及持续的城镇化进程,我国电力系统进入了一个快速发展阶段,电网建设得到进一步完善。目前,我国110KV及以上变电站的智能化程度总体水平较低。所以迫切需要提高变电站的智能化水平。
本次设计在一般变电站的基础上增加智能化的设备,例如在110KV侧智能断路器,电子式互感器等,提高了变电站的智能化水平,迎合了国内变电站的发展需求。在变电站自动化领域中,智能化电气的发展,特别是智能化开关、光电式互感器等机电一体化设备的出现,变电站自动化技术即将进入新阶段。变电站自动化系统是在计算机技术和网络通信技术基础上发展起来的。它以其简单可靠、可扩展性强、兼容性好等特点逐步为国内用户所接受,并在一些大型变电站监控项目中获得成功的应用。随着智能化开关,光电式电流电压互感器、一次运行设备在线状态检测及
3
自诊断、变电站运行操作培训仿真这些新技术的日趋成熟以及广泛应用必将对现有变电站自动化技术产生深刻的影响,带来全数字化的变电站新概念。
引入了智能化设备,提高变电站的综合自动化水平[3]是本次设计的亮点。但从整体上来讲,其设计与一般变电站相似,那么,本设计将分别阐释原始资料,主接线设计,短路电流计算,相关电气设备选择,变电站的整体布置,配电装置的安装,以及保护监测设备的使用,还有母线选择布置,无功补偿等等。本设计将会全面的讲述110KV降压变电站的初步设计内容,以及相关计算,选型和校验。从经济型,安全性,可靠性,实用性等多方面考虑,认真探讨研究了110kv变电站的一次部分初步设计。
4