aking PCMCIA version of object 36 taking PCMCIA version of object 48 taking PCMCIA version of object 49 taking PCMCIA version of object 50 taking PCMCIA version of object 51 taking PCMCIA version of object 52 taking PCMCIA version of object 63 taking PCMCIA version of object 67 taking PCMCIA version of object 68 taking PCMCIA version of object 70 taking PCMCIA version of object 71 taking PCMCIA version of object 72 taking PCMCIA version of object 75 taking PCMCIA version of object 76 taking PCMCIA version of object 77 taking PCMCIA version of object 79 taking PCMCIA version of object 97 taking PCMCIA version of object 112 taking PCMCIA version of object 113 taking PCMCIA version of object 145 taking PCMCIA version of object 162 taking PCMCIA version of object 163 taking PCMCIA version of object 164 taking PCMCIA version of object 177 taking PCMCIA version of object 200 (读取完毕) MMI-ROM 0000 -> MMI-ROM 0000 -> MMI-ROM 1015 -> set_site 40 (启动基站) Setting subsystem to 41 for site 40 Process 0x95 (Temp CM) requested a self-initiated soft reset !!! REBOOT !!! Reset due to self-initiated soft reset PCMCIA: Intel Series 2 Flash detected in socket 0 MMI-ROM 0000 -> MMI-ROM 0000 -> MMI-RAM 1015 -> Waiting for System Initialization to complete..... MMI-RAM 1015 -> Database display commands accepted. MMI-RAM 1015 -> Initialization complete. All commands accepted. MMI-RAM 1015 -> 26 室内分布系统及直放站培训手册

3.2.2 硬件连接

硬件的连接比较简单,但必须注意二点:一是做2M线头的要求比较严格,内线和针的接触要到位,外面的屏蔽网要接触完全,否则基站会经常出现闪断的情况;二是传输及基站的收发链路的接法要按:传输发-基站收、传输收-基站发,否则基站将无法下载数据。

3.2.3. 基站数据下载

由于用户权限的关系,基站数据下载只是一种确认工作;在以上工作确认无问题情况下,在MMI RAM 1015状态下进入第三操作层,按Ctrl+N后,在电脑屏幕上会弹出大量的微蜂窝的登录信息,这些信息可以不理会,在信息的最后面会出现DOWNLOAD的字眼,这表示基站开始数据下载。数据的下载过程需要半个小时左右的时间。

MMI-ROM 1015 -> chg_l Enter password for security level you wish to access:******** (密码) Enter password for security level you wish to access:******** (密码) Current security level is 3 (第三操作层) MMI-ROM 1015 -> 0 Nonfatal SWFM Error Routine: ip_rlink_read.c 0 Area: 0x00000050 Error: 0x00000002 PC: 0xc000f614 PID: 0x50 (MIP) 0 BSS Release: 1.6.1.4.b Obj Version: 1.6.1.4.b 0 01-Jan-1980 00:00:08.235 Subsystem: 0x00 CPU: 0x1015 Board: Apollo 0 rlink_read() returned unknown value 72 10 times 0 0 SWFM could not send fault report message to FCP MIP: Disable phase detector 1 and 2 MIP: SYNC pulse the phase det strobe MIP: 1015 is master MCU MIP: Establishing links to NIU frame 0, slot 0 NG EXEC DLSP dl_message_con: Control mailbox opened for channel 1, = 0 MCU:emon_1015 % NG EXEC_DLSP process_hdlc_msg: LINK ESTABLISHED for channel 1, Link Mailbox id = 1001 NG EXEC_DLSP process_hdlc_msg: NIU Flow mailbox id for channel 1 = 3001 MIP: HDLC link connected on frame 0, slot 0

…27 … ??BSC-DOWNLOAD?? 室内分布系统及直放站培训手册

3.3 开通后的工作

开通后的主要工作是拨打测试(Call Test),这里的拨打测试不同代维中巡检工作的拨打测试,而是要确认每个PCHN都可以通话,过程如下:用测试手机登录到该站,用该站信号拨打电话,并监听通话质量。

1、 查看信道通话情况:其中第一载频BCCH中有SDCCH这一项属于通话申请信道,其它为

通话信道TCH,在第二载频中就只有通话信道TCH。

2、 把正在通话的信道锁住:从下图可以看出,第一载频RTF 0 0 中的TCH3和TCH7正在

通话,监听到其通话质量没问题时,将TCH3锁住,让通话切换到其它TCH上,并继续监听通话质量;这样重复1和2步骤,直到所有的TCH被锁。被锁的TCH状态将变为OOS,不会再被通话占有,当最后一个TCH被锁时,正在通话的话音会立即中断。 3、 有TCH被锁后,拨打测试结束,这时把载波锁住;如果该站的邻小区切换参数已经做

好,可以重新解锁载波,恢复基站的通话,这样微蜂窝的开通工作就完成了。 4、 如果该站的邻小区切换参数未做,则记录该站的邻小区,把它们反馈到联通优化室,

要求他们加参数。

5、 如果是室外站,可以指导施工队把天线的方向角和倾角调到合理的方向。