一、概述 ··················································································· 2 二、技术指标 ··········································································· 2 三、面板介绍及说明 ······························································· 4 四、使用方法 ··········································································· 5 五、数据的查看和处理 ··························································· 8 六、注意事项 ········································································· 10 七、运输、贮存 ····································································· 10 八、附件清单 ········································································· 11
1
武汉市华天电力自动化有限责任公司
一、概述
变压器绕组的直流电阻测试是变压器在交接、大修和改变分接开关后,必不可少的试验项目。在通常情况下,用传统的方法(电桥法和压降法)测量变压器绕组以及大功率电感设备的直流电阻是一项费时费工的工作。为了改变这种状况,缩短测量时间以及减轻测试人员的工作负担,本公司开发了直流电阻快速测试仪(以下简称直阻仪)。它采用全新电源技术,具有性能稳定,测量迅速、体积小巧、使用方便、测量精度高,数据重复性好等特点。是测量变压器绕组以及大功率电感设备直流电阻的理想设备。
本产品符合DL/T845.3-2004与国家标准GB6587-86《电子测量仪器环境试验总纲》及GB6593-86《电子仪器质量检定规则》的要求。
二、技术指标
项目 测试电流 技术指标及参数 2.5A-5A-10A-20A-50A 2.5A: 10mΩ~8Ω 5A: 1mΩ~4Ω 10A: 1mΩ~2Ω 20A: 1mΩ~1Ω 50A: 1mΩ~500mΩ ±0.2%(满量程) 255个 2
备注 测量范围 测量准确度 数据存储
武汉市华天电力自动化有限责任公司 显示 最大分辨率 电源 最大功耗 工作环境 液晶显示器 0.1μΩ AC 220V±22V,50Hz±2 Hz 420W 环境温度:0℃~40℃ 相对湿度:≤80% 电阻显示为4 1/2位 保险管5A 测试电流为20A时 3
武汉市华天电力自动化有限责任公司
三、面板介绍及说明
面板如下图所示:
直阻仪的面板布局如上图所示,包括面板式打印机、液晶显示器、键盘、电源插座和开关、输出接线端子、接地端子等等。
输出部分:
输入输出接线端子如上图所示,共4只接线柱,其中外侧两只红色接线柱为电流输出,内侧两只接线柱为测量电压采样输入。
显示和键盘控制部分
4
武汉市华天电力自动化有限责任公司
50 A 1.0 0 0 0Ω 复测 退出 存储 打印
上图为液晶显示器和键盘组件组成的显示控制部分,其中显示器为点阵式液晶显示屏,用于显示操作提示、测量结果、以及指示显示屏下部4个多功能按键的用途。左侧的“Return”键可使仪器在出现死机或从菜单退出时直接返回到初始状态。最右侧的小孔为显示器对比度调节孔,在显示器出现显示图形对比度过深或过浅,影响阅读效果时,可以用小型“一”字改锥进行适当调节。
打印部分
本仪器提供的是16行微型面板式打印机,使用寿命长、打印速度快、更换打印纸和色带容易,无须其他维护和保养。整机电源接通后打印机右下角指示灯亮,表示打印机处于待机状态,测试中或测试完毕后根据显示提示按下打印键就可打印出数据。
四、使用方法
1、测量前的准备:
首先将电源线以及地线可靠连接到直阻仪上,然后把随机附带的测试线连接到直阻仪面板与其颜色相对应的输入输出接线端子上,将测试线末端的测试钳夹到待测变压器绕组两端,并用力摩擦接触点,以确保接触良好。接线方法如下图