OH-CON4723MRL调试手册 西子奥的斯电梯有限公司 文件编号:OH-CON4723MRL_SUR_ZH Unpublished Work Copyright ?XIZI OTIS Elevator Company
OH-CON4723MRL 1.0~1.75m/s No.: OH-CON4723MRL_SUR_ZH Date : 2007-06-15 Page : 2/34 FIM 工地调试手册 Pack 原始会签记录 编制 部门 日期 校对 部门 日期 审核 部门 日期 批准 部门 日期 授权AUTH. PC-LS0046-2007 部件版本 部件名称 LCBⅡ AMCBⅡ 变频器 硬件版本 GFA21240D10 1.0 FRENIC-Lift 软件版本 GAA30082DAA 3.5 1102 Unpublished Work Copyright ?XIZI OTIS Elevator Company
OH-CON4723MRL 1.0~1.75m/s No.: OH-CON4723MRL_SUR_ZH Date : 2007-06-15 Page : 3/34 FIM 工地调试手册 Pack 更 改 记 录 序号 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 更改PC 更改内容描述 更改日期 签 名 PC-LS0046-2007 首次归档 This work and the information it contains are the property of Xizi Otis Elevator Company (“XOEC”). It is delivered~others on the express condition that it will be used only for, or on behalf of, XOEC; that neither it nor the information it contains will be reported or disclosed, in whole or in part, without the prior written consent of XOEC, and that on demand it and any copies will be promptly returned~XOEC. Unpublished Work Copyright ?XIZI OTIS Elevator Company
OH-CON4723MRL 1.0~1.75m/s No.: OH-CON4723MRL_SUR_ZH Date : 2007-06-15 Page : 4/34 FIM 工地调试手册 目录 Pack 1 概述....................................................................................................................................................... 5 1.1 1.2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 总体框图 ...................................................................................................................................... 5 技术文件 ...................................................................................................................................... 6 检查控制柜................................................................................................................................... 7 接线检查 ...................................................................................................................................... 7 绝缘检查 ...................................................................................................................................... 7 检查输入电压 ............................................................................................................................... 7 检查控制变压器输出电压.............................................................................................................. 7 电动机动力线检查 ........................................................................................................................ 7 检查AMCBII电路板 .................................................................................................................... 7 2 检修模式运行条件检查 ...................................................................................................................... 7 3 检修模式LCBII上电检查 ................................................................................................................. 8 4 检查手动松闸HSD电路板 .............................................................................................................. 10 5 变频器参数设置................................................................................................................................. 10 6 AMCBII参数确认 ............................................................................................................................ 15 7 变频器数据的读写 ............................................................................................................................ 17 8 主机磁极自整定................................................................................................................................. 17 9 电梯运行方向检查 ............................................................................................................................ 19 10 点动运行模式..................................................................................................................................... 20 11 位置参考系统调整 ............................................................................................................................ 20 12 首次正常运行准备 ............................................................................................................................ 21 13 井道位置自学习................................................................................................................................. 22 14 DCS(门检测运行)操作 ................................................................................................................ 22 15 正常运行............................................................................................................................................. 23 16 平衡系数调整..................................................................................................................................... 23 17 正常运行的平层位置的调整 ............................................................................................................ 23 18 复位运行时的平层位置调整 ............................................................................................................ 24 19 松闸装置的调整................................................................................................................................. 24 20 故障排除............................................................................................................................................. 24 Unpublished Work Copyright ?XIZI OTIS Elevator Company
OH-CON4723MRL 1.0~1.75m/s No.: OH-CON4723MRL_SUR_ZH Date : 2007-06-15 Page : 5/34 FIM 工地调试手册 Pack 1 概述 OH-CON4723控制系统引用了LCBII作为电梯控制系统的核心,充分吸收了OTIS技术,利用OTIS高可靠性的串行通讯系统,将电梯的各个部件紧密的连在一起。驱动部分则采用富士的矢量变频技术,使电梯的运行更加平稳舒适,同时其流畅简洁的外观也令人赏心悦目。 1.1 总体框图 下图为OH-CON4723控制系统的基本框图和信号流程图。 IPDS码OTISLCBII1LS 2LS串行链路称重信号V码DZ生成速度曲线反馈运行状态码速度模拟量FUJI SIEI变频器AMCB2编码器分频(带 PR卡)速度反馈C/CC/HG/HDZ外部信号1LS 2LS抱闸HSD手动松闸 Unpublished Work Copyright ?XIZI OTIS Elevator Company