2019-05-24 20:06

hdisk1 Available MPIO Other FC SCSI Disk Drive hdisk2 Available MPIO Other FC SCSI Disk Drive hdisk3 Available MPIO Other FC SCSI Disk Drive hdisk4 Available MPIO Other FC SCSI Disk Drive hdisk5 Available MPIO Other FC SCSI Disk Drive hdisk6 Available MPIO Other FC SCSI Disk Drive hdisk7 Available MPIO Other FC SCSI Disk Drive hdisk8 Available MPIO Other FC SCSI Disk Drive hdisk9 Available MPIO Other FC SCSI Disk Drive hdisk10 Available MPIO Other FC SCSI Disk Drive hdisk11 Available MPIO Other FC SCSI Disk Drive hdisk12 Available MPIO Other FC SCSI Disk Drive $ lsdev -virtual | grep -E \vhost1 Available Virtual SCSI Server Adapter vtscsi5 Available Virtual Target Device - Disk vtscsi6 Available Virtual Target Device - Disk vtscsi7 Available Virtual Target Device - Disk vtscsi8 Available Virtual Target Device - Disk vtscsi9 Available Virtual Target Device - Disk $ lsmap -all

SVSA Physloc Client Partition ID

--------------- -------------------------------------------- ------------------

vhost1 U7998.61X.100390A-V1-C13 0x00000000

VTD vtscsi5

Status Available

LUN 0x8100000000000000 Backing device hdisk1 Physloc

U78A5.001.WIH0402-P1-C6-T1-W5005076303030053-L4011400300000000

VTD vtscsi6

Status Available LUN 0x8200000000000000 Backing device hdisk9 Physloc

U78A5.001.WIH0402-P1-C6-T1-W5005076303030053-L4011400B00000000

VTD vtscsi7

Status Available LUN 0x8300000000000000 Backing device hdisk10 Physloc

U78A5.001.WIH0402-P1-C6-T1-W5005076303030053-L4011400C00000000

VTD vtscsi8

Status Available

LUN 0x8400000000000000 Backing device hdisk11 Physloc

U78A5.001.WIH0402-P1-C6-T1-W5005076303030053-L4011400D00000000

VTD vtscsi9 Status Available LUN 0x8500000000000000 Backing device hdisk12 Physloc

U78A5.001.WIH0402-P1-C6-T1-W5005076303030053-L4011400E00000000 $

图 13:迁移后的 uli14

清单 5:迁移后 uli14 上的虚拟磁盘映射 $ lsdev | grep MPIO hdisk0 Available MPIO Other FC SCSI Disk Drive hdisk1 Available MPIO Other FC SCSI Disk Drive hdisk2 Available MPIO Other FC SCSI Disk Drive hdisk3 Available MPIO Other FC SCSI Disk Drive hdisk4 Available MPIO Other FC SCSI Disk Drive hdisk5 Available MPIO Other FC SCSI Disk Drive hdisk6 Available MPIO Other FC SCSI Disk Drive hdisk7 Available MPIO Other FC SCSI Disk Drive hdisk8 Available MPIO Other FC SCSI Disk Drive hdisk9 Available MPIO Other FC SCSI Disk Drive hdisk10 Available MPIO Other FC SCSI Disk Drive hdisk11 Available MPIO Other FC SCSI Disk Drive hdisk12 Available MPIO Other FC SCSI Disk Drive $ lsdev -virtual | grep -E \vhost0 Available Virtual SCSI Server Adapter vtscsi0 Available Virtual Target Device - Disk vtscsi1 Available Virtual Target Device - Disk vtscsi2 Available Virtual Target Device - Disk vtscsi3 Available Virtual Target Device - Disk vtscsi4 Available Virtual Target Device - Disk $ lsmap -all

SVSA Physloc Client Partition ID

--------------- -------------------------------------------- ------------------

vhost0 U7998.60X.100E7DA-V1-C11 0x00000001

VTD vtscsi0 Status Available LUN 0x8100000000000000 Backing device hdisk2

Physloc

U78A5.001.WIH1106-P1-C10-T1-W5005076303030053-L4011400400000000

VTD vtscsi1

Status Available

LUN 0x8200000000000000 Backing device hdisk5

Physloc

U78A5.001.WIH1106-P1-C10-T1-W5005076303030053-L4011400700000000

VTD vtscsi2

Status Available

LUN 0x8300000000000000 Backing device hdisk6 Physloc

U78A5.001.WIH1106-P1-C10-T1-W5005076303030053-L4011400800000000

VTD vtscsi3

Status Available

LUN 0x8400000000000000 Backing device hdisk7 Physloc

U78A5.001.WIH1106-P1-C10-T1-W5005076303030053-L4011400900000000

VTD vtscsi4

Status Available LUN 0x8500000000000000 Backing device hdisk8 Physloc U78A5.001.WIH1106-P1-C10-T1-W5005076303030053-L4011400A00000000 $ 查看迁移状态

上面说到系统管理员可以在分区迁移开始后在 IVM 上继续其他方面的系统管理工作,而不需要一直监视着分区迁移的状态。那么通过什么途径能够再次查看分区迁移的状态呢? 第一种方法是使用任务列表中“状态”选项(如图 14 所示)。在源系统的 IVM 上选择了该功能后,用户就可以再次看到分区迁移的状态页面了(如图 15 所示),通过该页面用户可以监视,停止或者恢复分区迁移。

图 14:IVM 任务列表

图 15:分区迁移的状态

另外一种方法是使用“服务管理”中的“监视任务”功能(如图 16 左部所示)。在源系统上选择了该功能后,IVM 会在窗口的右部显示所有任务的一个列表,其中包括分区迁移任务(如图 16 右部所示)。每个分区迁移任务只对应列表中的一项,迁移状态被持续的更新到该项中,因此每次看到的都是最新的状态。选择其中某个分区迁移任务,点击“属性”按钮,就可以看到当前分区迁移的状态(如图 16 右下角窗口所示)。图 16 所示的是 uli13lp1 迁移成功后的状态,如果在迁移过程中查看该项,则可以看到迁移的进度。

图 16:分区迁移的状态

命令行界面

除了上述 GUI 界面可用于分区迁移外,IVM 还提供了命令行界面(CLI)。GUI 界面使得系统管理员能够更加直观方便的进行分区迁移操作,而命令行界面则对于有计划的分区迁移和自动测试特别有用。

与 HMC 一样,IVM 也提供了 migrlpar 和 lslparmigr 两个新命令用于分区迁移。命令 migrlpar 用于检查,开始,停止分区迁移并从错误中恢复;命令 lslparmigr 用于查看分区迁移的状态。不过与 HMC 相比,IVM 提供的命令在语法上稍有不同。从清单 6 和清单 7 可以看出,IVM 命令行主要增加了 --ip ,-u 和 --async 三个选项。 清单 6:IVM 上分区迁移命令的语法 migrlpar [-o s | m | r | v -m [-t ] [-

-ip [-u ]] -p |--id [-n ][-f | -i \data>\[-w ] [-d ] [- -async] [-v] [--force] [--stderr] [--help]

lslparmigr -r manager | lpar | msp | procpool | sys | virtualio [-m

] [--ip

address> [-u

username>]] [--filter \[-F


在 - IBM - 集成虚拟化管理器上进行动态分区迁移(3).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!