泵与泵站课程设计

2019-05-27 19:41

目录

第一章 课程设计任务书············································2 第二章 中文摘要··················································3 第三章 设计计算书················································4

一、设计流量的确定和设计扬程估算······························4 1.设计流量Q·················································4 2.水泵所需静扬程HST·········································4 3.初选水泵和电机·············································5 4.机组基础尺寸的确定·········································5 5.压水管的设计···············································6 6.泵机组及管路布置·········································· 7.吸水井设计计算·············································· 8.泵站内管路的水力计算·····································

二、泵站各部分高度的确定··································· 1.泵房简体高度的确定····································· 2.泵房高度的确定··········································

三、泵房平面尺寸确定·······························

四、辅助设备的选择和布置····································· 1.起重设备······································ 2.引水设备········································ 3.排水设备··············································· 4.通风设备·············································· 5.计量设备···················································· 第四章 结语············································ 第五章 参考文献···············································

1 第一章 课程设计(论文)任务书

1.课程设计的主要内容及基本要求 (一)项目简介 某水厂一级泵站设计

张家口某水厂,近期用水量为4.1万米3/日,远期6.15万米3/日(不包括水厂自用水)原水厂水质符合饮用水规定。河边无冰冻现象,根据河岸地质地形以决定采用固定式泵房由吸水井中抽水,吸水井采用自流管从取水头部取水,取水头部采用箱式。取水头部到吸水井的距离为51米。水源洪水为标高为80.1米(1%频率);枯水位标高为75.5米(97%频率);常年平均水位标高为77.2米,泵房设置地室外地面标高为81.2m。净水厂混合井水面标高为107.2米,取水泵房到净水厂管道长570米。 地区气候资料可根据设计需要由当地气象部门提供。水厂为双电源进行。 (二)设计内容及要求

1、合理选择吸水井、吸水头部、水泵、配备动力设备,完成吸水井和机组布置;

2、设计吸水管路和压水管路的管径和埋深等; 3、计算确定水泵的安装高度;

4、进行泵站平面布置、大小和高程确定,并对泵站内主要附属设备进行选择。

(三)图纸及设计要求 1)、采用A2图纸出图。

2)、设计说明书用纸:A4纸打印或手写

3)、设计说明书要内容全面、思路清晰、规范及计算书要详细。 4)、设计说明书格式应满足“河北工业大学毕业设计格式”要求。

5)、最终成果严格按照河北工业大学课程设计要求排版装订,图纸可附计算说明书后。

2.设计参考资料

1.《水泵及水泵站成果整理并上交》 中国建筑工业出版社 姜乃昌 主编。 2.《给排水设计手册》第1、3、9、10、11册。

2 3.《泵站设计规范》 GB/T 50265—97

4.《地表水取水》 中国建筑工业出版社 周金全 主编。 3.进度安排 设计(论文)各阶段名称 1 基础资料收集和整理熟悉设计资料和设计规范 1天 2 方案比较、绘制水力草图 3 确定方案、设计计算 4 绘图、整理设计说明书 5 成果整理并上交

1天 2天 3天 1天 起 止 日 期

第二章 中文摘要

《水泵与水泵站》是一门实践性很强的学科,作为一种提升设备,它服务与社会,为人们的生产、生活、消防带来极大的方便因此它在现代的社会中发挥着不可替代的作用。然而,它又是一门大学问,对如何选则泵机组,如何搭配使用,如何布置泵基础和其他附属设备的平面及其高程,所以,选择合适的泵及其电机对泵站的投资和运行费用至关重要。 关键字:水泵 电机 泵站

3 第三章 设计计算书

一、设计流量的确定和设计扬程估算

1.设计流量Q

考虑到输水干管漏损和净化场本身用水,取自用水系数α=1.05,则: 近期设计流量为 Q=1.05×

350024=1793.75m/h=0.498 m/s

33

远期设计流量为Q'=1.05×

6150024=2690.625m3/h=0.747 m/s

3

2. 设计扬程H

1).泵所需静扬程

在最不利情况下(一条检修,另一条通过75%设计流量,Q=0.75×0.747 m/s=560L/s),查表DN=600mm,v=1.92m/s,1000i=7.48,其中取局部水头损失占沿程的10%,则取水头部到泵房吸水间的全部水头损失为:1.1×7.48×10?3×51=0.42m(其中量得取水头部到泵房吸水间的距离为51米)则:

吸水井最高水面标高为:80.10-0.42=79.68米 吸水井最低水面标高为:75.50-0.42=75.08米 所以水泵所需的静扬程

洪水位时:HST=107.20-79.68=27.52米; 枯水位时:HST=107.20-75.08=32.12米 2).输水干管的水头损失?h

设计中采用两条DN600钢管并联作为原水输水干管,管材选用钢管,既满足水泵吸水管的严密性要求,也满足耐高压的要求。

当一条输水管检修时,另一条输水管应通过75%设计流量,即:Q2=75%Q’=0.56 m/s,查得:V=1.92 m/s,1000i=7.48,所以,

3

3

?h=1.1×7.48×10

?3×570=4.69m(1.1是包括局部损失而加大的系数)

3).泵站内管路中的水头损失hp

4 粗估为2m

则水泵设计扬程为:

设计枯水为时,Hmax=32.12+4.69+2+2=40.81m 设计洪水位时,Hmin=27.52+4.69+2+2=36.21m

3. 初选水泵和电机

近期三台16SA—9J型水泵(Q=250~350L/s,扬程H=37~42m,泵轴功率N=129~150kw,转速960r/min,效率80~85%,气蚀余量4.6~5.2m,叶轮直径535mm),两台工作,一台备用。远期增加一台同型号水泵,三台工作一台备用。

根据16SA—9J型水泵的要求选用Y400—37—6电动机(200kw,泵重1910kg,电动机重2450kg)。

4. 机组基础尺寸的确定

查水泵与电机样本,可知道此种机组属于大中型不带底阀的泵机组,则有

基础长度L=水泵机组地脚螺孔长度方向间距+(400~500) =1747+500=2247mm取2300mm

基础宽度:B=水泵底角螺孔长度方向间距+(400~500) =700+480=1180mm 取1200mm

计算出Y400—37—6型水泵机组基础平面尺寸为2300×1200,机组总重量W=Wp+Wm=19100+24500=43600N

基础深度H可按下式计算:

H=

3.0?WL?B??

式中 L——基础长度,L=2m; B——基础宽度,B=1.2m;

——基础所用材料的容重,对于混凝土基础来说,=23520N/m3 故 H=

3.0?WL?B??=

3?436002.3?1.2?23520=2.01m