HAD-YCB型矢量控制永磁同步变频电梯门
机控制器使用说明书
Instruction of Type HAD-YCB Permanent magnet Synchronous Elevator door motor
controller using Vector variable
frequency control
天津市核奥达新技术开发有限公司
TIANJIN HEAODA NEW TECHNOLOGY
DEVELOPMENT CO.,LTD
1
重要提示:
Important notice:
1.轿厢运行前给出关门指令!
Before car runs, close door command must be given!
2.轿厢运行中必须始终给出关门指令!!!
In the process of car running, close door commend must always be given!!!
3.开关门控制信号必须是无源触点!
The control signal of opening or closing door must be passive contact.
4.厅轿门联动,不管门处于何种位置,不大于150牛顿力作用于门扇时,门应能够正常关闭。
When the landing door and the cage door move synchronously, wherever place the doors are, and when the power is not more than 150N at on the door panels, the door can close normally.
5.矢量控制永磁同步变频门机使用4096磁电编码器。
Vector control permanent magnet synchronous frequency conversion door operator use 4096 magnetoelectricity encoder.
6.对于同步门刀门机必须保证收刀后,再接通副门锁以确保电梯安全运行。
To the door operator having synchronous door knife must ensure that get auxiliary door lock after close the door knife.
7.电机外壳、门机控制器外壳、AC220电源的地线,必须可靠接地!!!
The motor casing, door controller shell and the power ground line of AC220 power supply are earthed properly.
一.安全规程
Installation process
2
1.1.安全注意事项 Notice of installation
1.1.1. 不能安装在含有易燃、易爆性气体的环境里(除专用防爆变频器),否则引起爆炸的危险。
Cannot be installed in the environment full of flammability or explosive gas (except for explosion-proof transducer), otherwise can cause the detonation danger. 1.1.2. 必须由具有专业资格的人员进行接线作业,否则有触电危险。
The wiring must be carried out by qualified personnel, otherwise electrocution can occur. 1.1.3. 确认输入电源处完全断开的情况下,才可进行接线操作,否则有触电危险。 Ensure that power supply has been cut off before commencing cable, otherwise electrocution can occur.
1.1.4. 必须将变频器的接地端子可靠接地,否则有触电危险或者造成门机不能正常工作。
Ensure the transducer earth properly, otherwise electrocution can occur or door motor refuse to work.
1.1.5. 操作及安装时应注意不能有金属、水、油或其他异物,否则损坏变频器或造成变频器不能正常工作。
Installation and operation should avoid all chips, oil, water or other foreign materials that can get into the door-motor transducer. 1.2. 使用注意事项 Notices of using
1.2.1. 在布线过程中始终注意信号线及控制线(弱电)与强电(36V以上)之间必须保持一定距离,不可混在一起布线,否则造成不能正常工作。
Keep distance between the weak electricity (signal wires and control wires) and strong electricity in the process of wiring.
1.2.2. 在轿厢起动前,控制系统必须给出关门指令,并且在轿厢升降过程中始终给出关门指令,避免门锁断开造成中途停车。
Before car running, control system must give close door command, and keep giving closed command as the process of car run to avoid stopping and breakoff of door lock and. 1.2.3. 此变频器采用自然冷却,周围应有一定散热空间。
The transducer adopts nature cooling method, and there should be some radiation space around. 二.产品介绍
Product introduction
1. 指标及规格
3
Technical index and specification 1.1.环境
Environment requirements
1.1.1. 使用场所:室内,不受阳光直射,无尘埃、腐蚀性气体、可燃性气体、油雾、水蒸汽等。
Using place: Using in house without dust, causticity gas, flammability gas, oil fog, vapor. 1.1.2. 海拔高度:低于1000M。 Altitude: less than 1000M 1.1.3. 工作温度:0℃~40℃。 Operating temperature range: 0℃~40℃。 1.1.4. 湿度:小于90%RH,无结露。
Relative humidity: < 90% without formation of steam 1.1.5. 贮存温度:-40℃~+70℃。 Storage temperature range: -40℃~+70℃ 1.2. 结构 Structure
1.2.1. 防护等级:IP40。 protection level: IP40
1.2.2. 冷却方式:自然冷却。 Cooling methods: nature cooling
1.2.3. 安装方式:壁挂式、平卧式。 Installation methods: Wall-hung, horizontal type 1.3. 输入、输出 Inputs and outputs
1.3.1. 输入电压范围:单相:180V~264V。 Input voltage: 180V~264V。
1.3.2. 输入频率: 50Hz—60Hz。 Input frequency: 50Hz-60Hz
1.3.3. 输出电压: 三相220V。 Output voltage: 3×220V AC 1.3.4. 输出功率: 0.4KW。 Output power: 0.4KW
1.4. 保护功能:过压保护,过流保护,欠压保护,旋转编码器不工作保护。。
Protection function: overvoltage protection, overcurrent protection, undervoltage
4
protection and the protection that the encoder doesn’t work. 1.5. HADXX----核奥达变频器软件版本标识。
HADXX---- software edition number of Heaoda transducer 2.安装接线。 Cabling and installation 2.1. 安装尺寸 Size of installation 单位(unit):mm
2.2. 端子说明 Terminal descriptions
2.2.1. 主回路端子 Main circuit terminal
5