~~~S1?(l1?2?l2?3?l3?A?)?S2?(l2?3?l3?A?)?S3?l3?A?~SA?1?lA?1?l1?2?l2?3?l3?A?

(42?j8.4)??56.57?100?63.25??(50?j10)??100?63.25??(35?j7)?63.25?72.11?56.57?100?63.25

?67.17?j13.43?MVA?

~~~S3??lA?1?l1?2?l2?3??S2??lA?1?l1?2??S1?lA?1~SA??3?lA?1?l1?2?l2?3?l3?A?

?(35?j7)??72.11?56.57?100??(50?j10)??72.11?56.57??(42?j8.4)?72.1172.11?56.57?100?63.25 ?59.83?j11.97?MVA?

~~~S1?2?SA?1?S1?(67.17?j13.43)?(42?j8.4)?25.17?j5.03?MVA?

~~~S3?2?SA??3?S3?(59.83?j11.97)?(35?j7)?24.83?j4.97?MVA?

?QA?1?13.43???cos?A?1?cos?arctan?cosarctan???0.98??P67.17??A?1?? ?Q1?2?5.03???cos?1?2?cos?arctan?cosarctan???0.98??P25.17??1?2?? ?Q2?3?4.97???cos?2?3?cos?arctan?cosarctan???0.98??P2?3?24.83??? cos?A??3?QA??3?11.97?????cos?arctan?cosarctan???0.98?P59.83??A??3??

表2.2 方案一线路容量

线路名称 A-1 1-2 3-2 A-3 输送容量输送距离电压等级最大负荷利最大负荷损(MVA) (km) (kv) 用小时(h) 耗时间 67.17 72.11 110 4000 3500 25.17 56.57 110 4500 3500 24.83 100 110 4500 3500 59.83 63.25 110 4000 3500 3.由于电压等级都为

UN?110KV,查附表得软导线经济电流密度

J?1.28A/mm2。各导线的截面积:

SA?1?22Pmax?Qmax3JUN67.172?13.432??280.88mm23?1.28?110

第 8 页

S1?2?22Pmax?Qmax3JUN22Pmax?Qmax25.172?5.032??105.25mm23?1.28?11024.832?4.972??103.83mm23?1.04?110

S2?3?3JUN22Pmax?Qmax

SA??3?3JUN59.832?11.972??250.19mm23?1.04?110

4.根据导线截面积选择导线型号从下面附表中,查导线电阻与电抗值,得出

参数如下表:

表2.3 导线的型号电阻和电抗

线路名称 A-1 1-2 3-2 A-3 横截面积导线型号 电阻 电抗 电压等充电允许截(mm) (?) (?) 级(kv) 功率 流量(A) 280.88 LGJ-300/40 0.105 0.395 110 3.82 735 105.25 LGJ-120/25 0.223 0.421 110 3.572 408 103.83 LGJ-120/25 0.223 0.421 110 3.572 408 250.19 LGJ-300/40 0.105 0.395 110 3.82 735 5.校验导线截面积(按允许载流量条件校验导线截面) (1)A—1段

a.故障时断开1—2段,则流入线路A—1的功率、电流分别为:

~~SA?1?S1?42?j8.4MVA

2IK?P2?Q23UN?422?8.42224.8A3?110

b.故障时断开A-3段,则流入线路A-1的功率、电流分别为:

~~~~SA?1?S1?S2?S3?42?j8.4?50?j10?35?j7?127?j25.4MVA

IK?(2)1-2段

P2?Q23UN1272?25.42??679.78A3?110

a.故障时断开A-1线路,则流入线路1-2的功率、电流分别为:

~~S1?2?S1?42?j8.4MVA

IK?P2?Q23UN422?8.42?224.8A3?110

b.故障时断开3-2线路,则流入线路1-2的功率,电流分别为:

~~S1?2?S2?50?j10MVA

第 9 页

IK?P2?Q23UN502?102??267.63A3?110

(3)3-2段

a.故障时断开1-2线路,则流入线路3-2的功率、电流分别为:

~~S3?2?S2?50?j10MVA

IK?P2?Q23UN502?102??267.63A3?110

b.故障时断开A-3线路,则流入线路3-2的功率,电流分别为:

~~S3?2?S3?35?j7MVA

IK?P2?Q23UN352?72??187.34A3?110

(4)A-3段

a.故障时断开3-2线路,则流入线路A-3的功率、电流分别为:

~~SA?3?S3?35?j7MVA

IK?P2?Q23UN352?72??187.34A3?110

b.故障时断开A-1线路,则流入线路A-3的功率,电流分别为:

~~~~SA?3?S1?S2?S3?42?j8.4?50?j10?35?j7?127?j25.4MVA

IK?P2?Q23UN1272?25.42??679.78A3?110

6.精确计算

(1)各线路的阻抗参数

RA?1?0.097?72.11?7? XA?1?0.386?72.11?27.83?

R1?2?0.21?56.57?11.88? X1?2?0.416?56.57?23.53?

R3?2?0.21?100?21? X3?2?0.416?100?41.6?

RA?3?0.097?63.25?6.14? XA?3?0.386?63.25?24.41?

ZA?1?7?j27.83? Z1?2?11.88?j23.53?

第 10 页

Z3?2?21?j41.6? ZA?3?6.14?j24.41?

(2)各段线路功率的分布情况

***~?*?~?*?~*S1?Z1?2?Z3?2?ZA?3??S2?Z3?2?ZA?3??S3?ZA?3~???SA?1??****ZA?1?Z1?2?Z3?2?ZA?3

?

4793.846?j7273.3846.02?j117.37

?67.59?j14.34MVA

~~~S1?2?SA?1?S1?25.59?j5.94MVA

~~~S3?2?S2?S1?2?24.41?j4.06MVA ~~~SA?3?S3?S3?2?59.41?j11.06MVA

(3)修正后的截面积

SA?1?22Pmax?Qmax3JUN22Pmax?Qmax67.592?14.342??348.7mm23?1.04?11025.592?5.942??123.58mm23?1.04?11024.412?4.062??124.88mm23?1.04?110

S1?2?3JUN22Pmax?Qmax

S3?2?3JUN22Pmax?Qmax

SA?3?3JUN59.412?11.062??304.98mm23?1.04?110

表2.4 方案一各线路导线的选择

线路 截面积导线型号 (mm) 2电阻 电抗 电压 110 110 110 110 A-1 348.7 LGJ-400/50 0.09 1-2 123.58 LGJ-150/25 0.21 3-2 124.88 LGJ-150/25 0.21 A-3 304.98 LGJ-400/50 0.09 2.2.2 方案二的初步潮流计算 0.386 0.416 0.416 0.386 充电功率(Mvar/100km) 3.912 3.618 3.618 3.912 允许截流量(A) 898 463 463 898 单位造价(万元/km) 34.9 22.02 22.02 34.9 根据假设的方向画出功率示意图:

第 11 页

~SA?3A~SA3~S3~SA?22~S21.各变电所的最大负荷

由原始资料可知cos?1?cos?2?cos?3?0.98,则tg?1?tg?2?tg?3?0.2

2.电力网络潮流计算

~S335?j7~??17.5?j3.5MVA SA?3单? 22~~S1?(l1?2?lA?2)?S2?lA?2~ SA?1?lA?1?l1?2?lA?2~A?1S~S1?2~S11

图2-2 方案二初步潮流计算

~S1?P1?jP1tg?1?42?j42?0.2?42?j8.4?MVA? ~S2?P2?jP2tg?2?50?j50?0.2?50?j10?MVA?

~S3?P3?jP3tg?3?35?j35?0.2?35?j7?MVA?