Apply Mesh OperationsNote: A transient solver does not use the adaptive meshing technique. Thus manual mesh specifications are required to refine the mesh in important regions to achieve accuracy of results.
Apply Mesh Operations for Core– Select the object Core from the history tree– Select the menu item Maxwell 3D Mesh Operations Assign On Selection Length Based– In Element Length Based Refinement window, 1. Name: Le
ngth1 2. Restrict Length Of Elements: Unchecked 3. Restrict the Number of Elements: Checked 4. Maximum Number of Elements: 1000 5. Press OK
© 2013 ANSYS, Inc.
May 21, 2013
12
Release 14.5