朔州宾馆工程脚手架施工方案 共32页第31页
计算时不计);
I=1699cm4 W=185.4cm3 10.5.1工字钢的弯曲强度:
PB2350PC800
A450D
λ
1
= 1450 / 2350 = 0.62
λ2 = 450 / 2350 = 0.19
MA = -Pm = -10.343(1.25+0.45) = -17.58 kN2m σ= MA/W=17.583106/185400=94.82N/mm2 < [f ]=215N/mm2 经计算,弯曲强度符合要求。 10.5.2整体稳定:
2????yt1?4320Ah?235 ???b???b??b?2?1???4.4h??fy?yWX?????
式中:βb = 0.21+0.67ξ = 0.21+0.67×0.79 = 0.74
式中:??l1t1?1250?10.7?0.79
b1h94?180A = 30.756cm2;λy = l1/iy = 1250 / 20 = 62.5(iy =2.0cm);ηb = 0
2432030.756?102?180?62.5?10.7????b?0.74????1?????3.21 > 0.6 21854004.4?18062.5??????
??1.07??b0.282?b?1.07?0.282?0.982 3.21
朔州宾馆工程脚手架施工方案 共32页第32页
2MA17.58?106??96.56N/mm ?WX0.982?185400?b < f = 215.0 N/mm2
Pm2l11.34?103?12502?2350?1??1???C???1?0.62??6.42mm 3EI3?2.06?105?1699?104
Pm2l11.34?103?4502?2350?1??2???D???1?0.19??0.61mm 3EI3?2.06?105?1669?104
Σν = 6.42+0.61 = 7.03 mm > [ν]= 2×1250 / 500 = 5.0 mm < [ν]= 2×1250 / 250 = 10.0 mm
(GB50017-2003附录A表A.1.1注1:“l为受弯构件的跨度—
—对悬臂梁和伸臂梁为悬伸长度的2倍”)
验算结果:悬臂梁的抗弯强度满足要求;变形值略大于l / 500但小
于l / 250,可。
10.5.3悬挑工字钢的地锚钢筋拉环
挑梁与楼板压点采用ф20地锚钢筋拉环,拉环强度计算如下: 挑梁与楼板压点的拉环受力 R=22.68 kN(取自两立杆受力叠加); 地锚拉环强度计算公式为:5
其中 [f] 为拉环钢筋抗拉强度,按照《混凝土结构设计规范》10.9.8条[f] = 50N/mm2;
所需要的水平钢梁与楼板压点的拉环最小直径 D=[2268034/(3.14235032)]1/2 =17 mm < 20mm
挑梁与楼板压点的地锚钢筋拉环要压在楼板下层钢筋下面,并要保证两侧30cm以上搭接长度。
10.5.4 钢丝绳保险体系 根据DB11/T583-2008规定:“悬挑脚手架宜采取钢丝绳保险体系” 规定,挑梁悬挑端增加斜拉钢丝绳保险:采用6×19,¢15.5钢丝绳。