20. UplinkBaseBandPool_UlHwLessThanUlCapacity 上行容量告警
Maj Plug-In Unit General Problem replaceable_unit_problem Subrack=1,Slot=9,PlugInUnit=1 Min UplinkBaseBandPool_UlHwLessThanUlCapacity configuration_or_customizing_error
Subrack=1,UplinkBaseBandPool=1 告警原因:下行容量低于license容量 影响:无
处理方法:一般为2块RAX板中有一块读不到,换到故障RAX板即可解决
20. DownlinkBaseBandPool_DlHwLessThanDlCapacity : 下行容量告警
Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=1-UL Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=2-UL Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=3-UL Min DownlinkBaseBandPool_DlHwLessThanDlCapacity configuration_or_customizing_error
Subrack=1,DownlinkBaseBandPool=1 Min UplinkBaseBandPool_UlHwLessThanUlCapacity configuration_or_customizing_error
Subrack=1,UplinkBaseBandPool=1 告警原因:下行容量低于license。 影响:无影响
解决方法:该站RRU接通后,该告警会自动消除。
21. FcuDeviceGroup_EnclosureDoorOpen 门禁告警
Maj FcuDeviceGroup_EnclosureDoorOpen enclosure_door_open_m3100 AuxPlugInUnit=2,FcuDeviceGroup=1 告警原因:机框门没关 影响:无
解决方法:到现场关闭机框门,此告警为3518特有告警。
22. Loss of Tracking 丢失同步
Loss of Tracking replaceable_unit_problem Synchronization=1
Min Loss of Synch Reference Redundancy replaceable_unit_problem Synchronization=1 告警原因:丢失同步
影响:如果2调同步传输同事出现该告警,会导致该站退服。
处理方法:对丢失同步的基站进行resetLossOfTracking 操作可消除该告警,但如是传输误码导致的告警,消除后则
可能再次出现。