20. UplinkBaseBandPool_UlHwLessThanUlCapacity 上行容量告警

Maj Plug-In Unit General Problem replaceable_unit_problem Subrack=1,Slot=9,PlugInUnit=1 Min UplinkBaseBandPool_UlHwLessThanUlCapacity configuration_or_customizing_error

Subrack=1,UplinkBaseBandPool=1 告警原因:下行容量低于license容量 影响:无

处理方法:一般为2块RAX板中有一块读不到,换到故障RAX板即可解决

20. DownlinkBaseBandPool_DlHwLessThanDlCapacity : 下行容量告警

Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=1-UL Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=2-UL Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=3-UL Min DownlinkBaseBandPool_DlHwLessThanDlCapacity configuration_or_customizing_error

Subrack=1,DownlinkBaseBandPool=1 Min UplinkBaseBandPool_UlHwLessThanUlCapacity configuration_or_customizing_error

Subrack=1,UplinkBaseBandPool=1 告警原因:下行容量低于license。 影响:无影响

解决方法:该站RRU接通后,该告警会自动消除。

21. FcuDeviceGroup_EnclosureDoorOpen 门禁告警

Maj FcuDeviceGroup_EnclosureDoorOpen enclosure_door_open_m3100 AuxPlugInUnit=2,FcuDeviceGroup=1 告警原因:机框门没关 影响:无

解决方法:到现场关闭机框门,此告警为3518特有告警。

22. Loss of Tracking 丢失同步

Loss of Tracking replaceable_unit_problem Synchronization=1

Min Loss of Synch Reference Redundancy replaceable_unit_problem Synchronization=1 告警原因:丢失同步

影响:如果2调同步传输同事出现该告警,会导致该站退服。

处理方法:对丢失同步的基站进行resetLossOfTracking 操作可消除该告警,但如是传输误码导致的告警,消除后则

可能再次出现。