移频轨道电路室外监测系统施工调试规范(3)

2018-12-14 23:00

【移频轨道电路室外监测系统施工调试规范】

20=946BG, 19, 132, 130 21=966AG, 20, 133, 131 22=966BG, 21, 134, 132 23=984AG, 22, 135, 133 24=984BG, 23, 136, 134 25=1004AG, 24, 137, 135 26=1004BG, 25, 138, 136 27=1022AG, 26, 139, 137 28=1022BG, 27, -1, 138

[模块区段对应表] 总路数=28

;;该段是串口服务器中通讯模块和显示中的实际区段的对应表

;;区间名称,区间ID(从0开始,必须连续),发送模块区段ID,接收模块区段ID ;;现在FS区间ID和JS区段ID都是一样的 1= 885BG, 0, 0, 0 2= 885AG, 1, 1, 1 3= 905BG, 2, 2, 2 4= 905AG, 3, 3, 3 5= 925BG, 4, 4, 4 6= 925AG, 5, 5, 5 7= 943BG, 6, 6, 6 8= 943AG, 7, 7, 7 9= 963BG, 8, 8, 8 10= 963AG, 9, 9, 9 11= 983BG, 10, 10, 10 12= 983AG, 11, 11, 11 13= 1003BG, 12, 12, 12 14= 1003AG, 13, 13, 13 15= 906AG, 14, 14, 14 16= 906BG, 15, 15, 15 17= 926AG, 16, 16, 16 18= 926BG, 17, 17, 17 19= 946AG, 18, 18, 18 20= 946BG, 19, 19, 19 21= 966AG, 20, 20, 20 22= 966BG, 21, 21, 21 23= 984AG, 22, 22, 22 24= 984BG, 23, 23, 23 25= 1004AG, 24, 24, 24 26= 1004BG, 25, 25, 25 27= 1022AG, 26, 26, 26 28= 1022BG, 27, 27, 27

第 11 页 共 42 页

【移频轨道电路室外监测系统施工调试规范】

串口服务器部分 [通信设置] 命令周期=5000

;;单位毫秒,命令发送周期 本机IP地址=127.0.0.1

;;如果站机和串口服务器在一台机器上,必须设为127.0.0.1 串口数量=0;;按实际使用的485线总数配 [电力载波区段]

虚拟分机号=1;;总共只有一个虚拟分机号 命令周期=5000

;;单位毫秒,命令发送周期 总路数=56;;模块总数

;; 名称,序号,协议标志,区段ID(从0开始,顺序递增,所有区段一起编号) ;; 模块IP ,模块端口, 服务器串口IP

;; ,服务器串口端口(一个模块对应一个服务器端口,不能重复),

;; 数据接收超时延时(接收,毫秒),发送接收标志(发送2,接收1) 1= 885BG-FS, 0, 2, 0, 192.168.10.177, 9000, 192.168.10.33, 0, 1000, 2

2= 885BG-JS, 1, 2, 0, 192.168.10.177, 9001, 192.168.10.33, 5002, 1000, 1

3= 885AG-FS, 2, 2, 1, 192.168.10.177, 9002, 192.168.10.33, 5003, 1000, 2

4= 885AG-JS, 3, 2, 1, 192.168.10.177, 9003, 192.168.10.33, 5004, 1000, 1

5= 905BG-FS, 4, 2, 2, 192.168.10.177, 9004, 192.168.10.33, 1000, 1000, 2

6= 905BG-JS, 5, 2, 2, 192.168.10.177, 9005, 192.168.10.33, 5006, 1000, 1

7= 905AG-FS, 6, 2, 3, 192.168.10.177, 9006, 192.168.10.33, 5007, 1000, 2

8= 905AG-JS, 7, 2, 3, 192.168.10.177, 9007, 192.168.10.33, 5008, 1000, 1

9= 925BG-FS, 8, 2, 4, 192.168.10.177, 9008, 192.168.10.33, 5009, 1000, 2

10= 925BG-JS, 9, 2, 4, 192.168.10.177, 9009, 192.168.10.33, 5010, 1000, 1

11= 925AG-FS, 10, 2, 5, 192.168.10.177, 9010, 192.168.10.33, 5011, 1000, 2

12= 925AG-JS, 11, 2, 5, 192.168.10.177, 9011, 192.168.10.33, 5012, 1000, 1

13= 943BG-FS, 12, 2, 6, 192.168.10.177, 9012, 192.168.10.33, 5013, 1000, 2

第 12 页 共 42 页

【移频轨道电路室外监测系统施工调试规范】

14= 943BG-JS, 13, 2, 1000, 1 15= 943AG-FS, 14, 2, 1000, 2 16= 943AG-JS, 15, 2, 1000, 1 17= 963BG-FS, 16, 2, 1000, 2 18= 963BG-JS, 17, 2, 1000, 1 19= 963AG-FS, 18, 2, 1000, 2 20= 963AG-JS, 19, 2, 1000, 1 21= 983BG-FS, 20, 2, 1000, 2 22= 983BG-JS, 21, 2, 1000, 1 23= 983AG-FS, 22, 2, 1000, 2 24= 983AG-JS, 23, 2, 1000, 1 25= 1003BG-FS, 24, 2, 1000, 2 26= 1003BG-JS, 25, 2, 1000, 1 27= 1003AG-FS, 26, 2, 1000, 2 28= 1003AG-JS, 27, 2, 1000, 1 29= 906AG-FS, 28, 2, 1000, 2 30= 906AG-JS, 29, 2, 1000, 1 31= 906BG-FS, 30, 2, 1000, 2 32= 906BG-JS, 31, 2, 1000, 1 33= 926AG-FS, 32, 2, 1000, 2 34= 926AG-JS, 33, 2, 1000, 1 35= 926BG-FS, 34, 2, 1000, 2

6, 192.168.10.177, 9013, 7, 192.168.10.177, 9014, 7, 192.168.10.177, 9015, 8, 192.168.10.177, 9016, 8, 192.168.10.177, 9017, 9, 192.168.10.177, 9018, 9, 192.168.10.177, 9019, 10, 192.168.10.177, 9020, 10, 192.168.10.177, 9021, 11, 192.168.10.177, 9022, 11, 192.168.10.177, 9023, 12, 192.168.10.177, 9024, 12, 192.168.10.177, 9025, 13, 192.168.10.177, 9026, 13, 192.168.10.177, 9027, 14, 192.168.10.177, 9028, 14, 192.168.10.177, 9029, 15, 192.168.10.177, 9030, 15, 192.168.10.177, 9031, 16, 192.168.10.177, 9032, 16, 192.168.10.177, 9033, 17, 192.168.10.177,

9034,

第 13 页 共 42 页

192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33,

5014,5015,5016,5017,5018,5019,1000,5021,5022,5023,5024,5025,5026,5027,5028,5029,5030,5031,5032,5033,5034,5035,

【移频轨道电路室外监测系统施工调试规范】

36= 926BG-JS, 35, 2, 1000, 1 37= 946AG-FS, 36, 2, 1000, 2 38= 946AG-JS, 37, 2, 1000, 1 39= 946BG-FS, 38, 2, 1000, 2 40= 946BG-JS, 39, 2, 1000, 1 41= 966AG-FS, 40, 2, 1000, 2 42= 966AG-JS, 41, 2, 1000, 1 43= 966BG-FS, 42, 2, 1000, 2 44= 966BG-JS, 43, 2, 1000, 1 45= 984AG-FS, 44, 2, 1000, 2 46= 984AG-JS, 45, 2, 1000, 1 47= 984BG-FS, 46, 2, 1000, 2 48= 984BG-JS, 47, 2, 1000, 1 49= 1004AG-FS, 48, 2, 1000, 2 50= 1004AG-JS, 49, 2, 1000, 1 51= 1004BG-FS, 50, 2, 1000, 2 52= 1004BG-JS, 51, 2, 1000, 1 53= 1022AG-FS, 52, 2, 1000, 2

17, 192.168.10.177, 9035, 18, 192.168.10.177, 9036, 18, 192.168.10.177, 9037, 19, 192.168.10.177, 9038, 19, 192.168.10.177, 9039, 20, 192.168.10.177, 9040, 20, 192.168.10.177, 9041, 21, 192.168.10.177, 9042, 21, 192.168.10.177, 9043, 22, 192.168.10.177, 9044, 22, 192.168.10.177, 9045, 23, 192.168.10.177, 9046, 23, 192.168.10.177, 9047, 24, 192.168.10.177, 9048, 24, 192.168.10.177, 9049, 25, 192.168.10.177, 9050, 25, 192.168.10.177, 9051, 26, 192.168.10.177,

9052,

第 14 页 共 42 页

192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33, 192.168.10.33,

5036,5037,5038,5039,5040,5041,5042,5043,5044,5045,5046,5047,5048,5049,5050,5051,5052,5053,

【移频轨道电路室外监测系统施工调试规范】

五、安装调试

5.1 WSM型号区间监测室内设备安装、配线 5.1.1 设备安装

安装区间监测电源箱、UPS电源(按合同要求配置)、串口服务器、显示器、鼠标、键盘等。区间监测电源箱、串口服务器均采用了标准的机架式结构。其中区间监测电源箱为标准4U,串口服务器为标准1U。目前主要采用两种安装方式: 1) 单设机柜及设备集中柜。

单独设置一台机柜,将区间监测电源箱、串口服务器等装入机柜。显示器、鼠标、键盘等装入设备集中柜,通过键鼠延长线、视频延长线实现机柜和设备集中柜间的连接。 2) 利用既有集中监测机柜及设备集中柜。

将区间监测电源箱、串口服务器等装入既有信号集中监测机柜中,显示器并排放置于信号集中监测显示器边上,鼠标、键盘放在设备集中柜桌面。通过键鼠延长线、视频延长线实现机柜和设备集中柜间的连接。

区间监测防雷组合一般安装在区间接口综合柜或分线盘,需要根据现场勘测表定制组合尺寸。区间监测防雷组合中喊电源防雷和通信防雷。如下图所示:

第 15 页 共 42 页


移频轨道电路室外监测系统施工调试规范(3).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!

下一篇:寒假教师培训讲稿(王明开)

相关阅读
本类排行
× 注册会员免费下载(下载后可以自由复制和排版)

马上注册会员

注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。