超高模板支架施工方案(3)

2019-03-22 10:31

2.755/1.0+0.014+1.126+0.722]=7.589kN/m 计算简图如下:

1、强度验算

Mmax=0.1ql2=0.1×7.589×0.442=0.147kN·m σmax=Mmax/W=0.147×106/40833=3.598N/mm2≤fm=13N/mm2 符合要求! 2、抗剪验算 Qmax=0.6ql=0.6×7.589×0.44=2.004kN τmax=3Qmax/(2bh0)=3×2.004×1000/(2×50×70)=0.859N/mm2 τmax=0.859N/mm2≤fv=1.3N/mm2 符合要求! 3、挠度验算

νmax=0.677ql4/(100EI)=0.677×7.589×4404/(100×9000×1429170)=0.15mm νmax=0.15mm≤[ν]=min[l/250,10]=min[440/250,10]=1.76mm 符合要求!

4、支座反力计算

梁底次楞依次最大支座反力为: R1=1.1×(2.755+0.014+1.126+0.722)×0.44=2.235kN R2=1.1×(7.576+0.014)×0.44=3.673kN R3=1.1×(7.576+0.014)×0.44=3.673kN R4=1.1×(2.755+0.014+1.126+0.722)×0.44=2.235kN

六、主楞(横向水平钢管)验算

主楞材质类型 主楞材料自重(kN/m) 主楞抗弯强度设计值Fm(N/mm) 主楞截面抵抗矩W(cm) 主楞弹性模量E(N/mm) 232钢管 0.033 205 4.49 206000 主楞材料规格(mm) 主楞截面面积(mm) 主楞抗剪强度设计值fv(N/mm) 主楞截面惯性矩I(cm) 422Ф48×3 424 125 10.78 主楞自重荷载:q1=γGq=1.35×0.033=0.045kN/m 计算简图如下:

11

1、强度验算 Mmax=0.163kN·m σmax=Mmax/W=0.163×106/4490=36.199N/mm2≤fm=205N/mm2 符合要求! 2、抗剪验算 Qmax=3.68kN τmax=2Qmax/A=2×3.68×1000/424=17.356N/mm2 τmax=17.356N/mm2≤fv=125N/mm2 符合要求! 3、挠度验算

νmax=0.035mm≤[ν]=min[l/250,10]=min[330/250,10]=1.32mm 符合要求! 4、支座反力

支座反力依次为R1=0.056kN,R2=5.874kN,R3=5.874kN,R4=0.056kN

七、纵向水平钢管验算

纵向水平钢管仅起构造作用,可不用计算。

八、扣件抗滑验算

是否考虑荷载叠合效应 是 扣件抗滑承载力设计值折减系数 0.8 最大支座反力Rmax=5.874kN 1.05×Rmax=1.05×5.874=6.167kN,6.167kN≤0.8×12.0=9.6kN 在扭矩达到40~65N·m的情况下,双扣件能满足要求!

九、模板支架整体高宽比验算

H/Lb=10.9/60=0.182<5 符合要求!

十、立杆验算

钢管类型 截面回转半径i(mm) 抗压、弯强度设计值[f](N/mm) 2Ф48×3 15.9 205 截面面积A(mm) 截面抵抗矩W(cm) 32424 4.49 1、长细比验算

12

h/la=1800/440=4.091,h/lb=1800/950=1.895,查附录D,得k=1.163,μ=1.299 l0=max[kμh,h+2a]=max[1.163×1.299×1800,1800+2×50]=2719mm λ=l0/i=2719/15.9=172≤[λ]=210 长细比符合要求!

查《规程》附录C得 υ=0.24 2、风荷载验算

1) 模板支架风荷载标准值计算

la=0.44m,h=1.8m,查《规程》表4.2.7得υw=0.166

因风荷载沿模板支架横向作用,所以b=la=0.44m,b/h=0.44/1.8=0.244 通过插入法求η,得η=0.95 μzω0d2=1×0.5×0.0482=0.001,h/d=1.8/0.048=37.5 通过插入法求μs1,得μs1=1.2

因此μstw=υwμs1(1-ηn)/( 1-η)=0.166×1.2×(1-0.9570)/(1-0.95)=3.874 μs=υwμstw=0.166×3.874=0.643 ωk=0.7μzμsω0=0.7×1×0.643×0.5=0.225kN/m2 2) 整体侧向力标准值计算 ωk=0.7μzμsω0=0.7×1×1×0.5=0.35kN/m2 3、稳定性验算 KH=1/[1+0.005×(10.9-4)]=0.967

1) 不组合风荷载时立杆从左到右受力为(Nut=γG∑NGk+1.4∑NQk):

R1=0.056+[1.35×(0.3+(24+1.1)×0.13)×0.44+1.4×(1+2)×0.44]×(0.81/2+(0.475-0.45/2)/2) +1.35×0.15×10.9=4.364kN R2=5.874+1.35×0.15×(10.9-1.2)=7.838kN R3=5.874+1.35×0.15×(10.9-1.2)=7.838kN

R4=0.056+[1.35×(0.3+(24+1.1)×0.13)×0.44+1.4×(1+2)×0.44]×(0.81/2+(0.95-0.475-0.45/2)/2) +1.35×0.15×10.9=4.364kN

Nut=max[R1,R2,R3,R4]=max[4.364, 7.838, 7.838, 4.364]=7.838kN

1.05Nut/(υAKH)=1.05×7.838×103/(0.24×424×0.967)=83.664N/mm2≤[f]=205N/mm2 符合要求!

2) 组合风荷载时立杆从左到右受力为(Nut=γG∑NGk+0.85×1.4∑NQk): R1=4.212kN, R2=7.736kN, R3=7.736kN, R4=4.212kN

Nut=max[R1,R2,R3,R4]=max[4.212, 7.736, 7.736, 4.212]=7.736kN Mw=0.85×1.4ωk lah2/10=0.85×1.4×0.225×0.44×1.82/10=0.038kN·m 1.05Nut/(υAKH)+Mw/W= 1.05×7.736×103/(0.24×424×0.967)+0.038×106/(4.49×103)=91.082N/mm2≤[f]=205N/mm2

符合要求!

4、整体侧向力验算 结构模板纵向挡风面积AF(m)

233 13

F=0.85AFωkla/La=0.85×33×0.35×0.44/80=0.054kN N1=3FH/[(m+1)Lb]=3×0.054×10.9/[(34+1)×60]=0.001kN σ=(1.05Nut+N1)/(υAKH)= (1.05×7.736+0.001)×103/(0.24×424×0.967)=82.587N/mm2≤[f]=205N/mm2 符合要求!

九、混凝土板模板支架承载力验算 一、工程概况

新浇混凝土板特性 模板支架高度H(m) 模板支架的横向长度Lb(m) 超高 10.9 60 新浇混凝土楼板厚度(mm) 模板支架的纵向长度La(m) 130 80 二、模板支撑体系设计

立杆纵向间距la(mm) 纵横向水平杆步距h(mm) 880 1800 立杆横向间距lb(mm) 次楞布置方式 810 平行于立杆纵向方向 次楞间距(mm) 扣件抗滑承载力设计值折减系数 270 0.8 荷载传递至立杆方式 双扣件 设计简图如下:

模板设计平面图

14

模板设计纵向剖面图

模板设计横向剖面图

15


超高模板支架施工方案(3).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!

下一篇:最新北师大版七年级数学下1.1同底数幂的乘法同步练习含答案

相关阅读
本类排行
× 注册会员免费下载(下载后可以自由复制和排版)

马上注册会员

注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信: QQ: