M – 1 – 2
TEST – Menu > Event = 1 Diag = 2 1 2 3 4 5 clear
00000 total runs 00000 minutes on
Event – Function Diagnosis – Function Part – Function RSL – Funtion Selftest – Func.
Figure 5-10: TEST – Functions
In the following all the TEST – functions are explained. There are the Events, Diagnosis, Part, RSL and Selftest functions, which are the most used functions for service and maintainace. Short Key S6 is assigned to call the Event – function.
The Diagnosis – function operates the diagnosis parameter stored in The EEPROM after Power – OFF.
Part displays the configuration number of EPROM and EEPROM, RSL and Selftest are functions to test the hardware of the LCB_II.
5.2.1 Event – Function
Key Sequence
M – 1 – 2 – 1 Event S6
Short Key
00000 total runs 00000 minutes on
1)
The Event – Function support the maintenance of The elevator.
It displays - the total number of runs - the elapsed time since Power On - information about each event:
- event text
- the number of event
- the elapsed time since last
occurrence
- the car position where the last
event occurred
Please refer to the list of Event Messages: (see document: Service Tool Reference List)
global information number of elevator runs number since Power On
00000 total runs 00000 minutes on 2) 1) 00000
2) 00000
goon goon (GOBACK) - Key GOON / Shift Key GOBACK: Skip through the list of recorded event messages. 00000 total runs 00000 total runs 00000 minutes on 00000 minutes on No events 0400 RSL parity logged____ c002 t00001 p** No more event logged a) no event recorded b) one event recorded
Event logging 4) 1 2) 3) 1) 1.row 2) 002
0400 RSL parity c002 t00001 p** 3) 00001
event logging event text number of event since last occurrence Event reset
elapsed time since last occurrence (minutes) 4) ** car position where event occurred finally (** = position not defined)
1 (ON) clear (ENTER) 2 (UP) clean 1 (ENTER) clear 2 (ENTER) clear - Shift Key ON: Reset the displayed event. - Shift Key ENTER: Termination of the reset Function. - Shift Key UP: Reset the entire event Logging. - Key 1 and ENTER and Key 2 and ENTER : Termination of the reset Function. - Key CLEAR: back to Test - Menu Erase Value ? 0400 RSL parity Erase Value ? done ! Erase Events ? n = 0 y = 1 > Erase Events ? Please wait! 5.2.2 Diagnosis - Function
Key Sequence
In Figure 5-12 you can see the display of function Diagnosis. The first row displays the name of the current diagnosis parameter. 01 DIAG ACT - T 000 : 00 : 00 : 34
Figure 5-12 : Diagnosis - Function
The second row shows the value of the diagnosis parameter.
- You can skip to the next / previous diagnosis parameter with Key GOON / GOBACK - With Key UP you can display a short legend for the time values.
- The displayed parameter can be reset to zero using the key sequence ON/UP and ENTER. Please refer to the list of Diagnosis Parameters.
Diagnosis Parameter display
Example of a time parameter
M – 1 – 2 - 2
1) 02 DIAG TOT - T 003 : 17 : 22 : 57 3) 4) 5) 6) 2) Display Field 1) 02 2) TOT-T 3) 003 4) 17 5) 22 6) 37 Description Parameter no. Parameter name No. of months No. of days No. of hours No. of minutes Example of a time parameter
1) 2)
Display Field Description
03 DIAG UP - CNT 0 0 0 0 0 0 0 7 9 1) 03 Parameter no. 2) UP-CNT Parameter name 3) 000000079 No. of occurrences 3) Diagnosis parameter reset 1 (ON) clear (ENTER) 2 (UP) 2 (UP) clear 1 (ENTER) clear 2 (ENTER)
clear
- Shift Key ON: Reset the displayed event - Shift Key ENTER: Termination of the reset function. - Shift Key UP displays a short legend of the time value – if a time – value was displayed before. - Shift Key UP(a 2,time): Resets the entire event Logging. - Key and ENTER and - Key and ENTER: Termination of the reset Function. - Key CLEAR: back to Test - Menu Erase Value ? 02 DIAG TOT - T Erase Value ? done ! mon : d : h : min 003 : 17 : 22 : 57 Erase Events ? n = 0 y = 1 > Erase Events ? Please wait!