梁底增加立柱依次距梁左侧立柱距离(mm) 梁底支撑小梁根数 梁底支撑小梁一端悬挑长度(mm) 450,750 6 150 设计简图如下:

平面图

- 11 -

立面图

4、面板验算

面板类型 面板抗弯强度设计值[f](N/mm) 2覆面木胶合板 15 面板厚度(mm) 面板弹性模量E(N/mm) 215 10000 取单位宽度1000mm,按四等跨连续梁计算,计算简图如下:

W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=0.9max[1.2(G1k+ (G2k+G3k)×h)+1.4Q1k,1.35(G1k+

- 12 -

(G2k+G3k)×h)+1.4×0.7Q1k]×b=0.9max[1.2×(0.1+(24+1.5)×2)+1.4×2,1.35×(0.1+(24+1.5)×2)+1.4×0.7×2]×1=63.85kN/m

q1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×2]×1=62.09kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.76kN/m q2=(G1k+ (G2k+G3k)×h)×b=[0.1+(24+1.5)×2]×1=51.1kN/m (1)、强度验算

Mmax=-0.107q1静L2+0.121q1活L2=-0.107×62.09×0.182+0.121×1.76×0.182=0.21kN·m σ=Mmax/W=0.21×106/37500=5.56N/mm2≤[f]=15N/mm2 满足要求! (2)、挠度验算

νmax=0.632qL4/(100EI)=0.632×51.1×1804/(100×10000×281250)=0.121mm≤[ν]=l/400=180/400=0.45mm 满足要求!

(3)、支座反力计算 设计值(承载能力极限状态)

R1=R5=0.393 q1静l +0.446 q1活l=0.393×62.09×0.18+0.446×1.76×0.18=4.53kN R2=R4=1.143 q1静l +1.223 q1活l=1.143×62.09×0.18+1.223×1.76×0.18=13.16kN R3=0.928 q1静l +1.142 q1活l=0.928×62.09×0.18+1.142×1.76×0.18=10.73kN 标准值(正常使用极限状态)

R1'=R5'=0.393 q2l=0.393×51.1×0.18=3.61kN R2'=R4'=1.143 q2l=1.143×51.1×0.18=10.51kN R3'=0.928 q2l=0.928×51.1×0.18=8.54kN

5、小梁验算

小梁类型

小梁抗弯强度设计值[f](N/mm) 小梁弹性模量E(N/mm) 小梁截面惯性矩I(cm)

42

2

方木 15.44 9350 170.67

小梁材料规格(mm)

小梁抗剪强度设计值[τ](N/mm) 小梁截面抵抗矩W(cm)

3

2

40×80 1.78 42.67

为简化计算,按四等跨连续梁和悬臂梁分别计算,如下图:

- 13 -

q1=

max{4.53+0.9×1.35×[(0.3-0.1)×0.9/5+0.5×(2-0.18)]+0.9max[1.2×(0.5+(24+1.1)×0.18)+1.4×2,1.35×(0.5+(24+1.1)×0.18)+1.4×0.7×2]×max[0.6-0.9/2,(1.2-0.6)-0.9/2]/2×1,13.16+0.9×1.35×(0.3-0.1)×0.9/5}=13.21kN/m

q2=max[3.61+(0.3-0.1)×0.9/5+0.5×(2-0.18)+(0.5+(24+1.1)×0.18)×max[0.6-0.9/2,(1.2-0.6)-0.9/2]/2×1,10.51+(0.3-0.1)×0.9/5]=10.55kN/m (1)、抗弯验算

Mmax=max[0.107q1l12,0.5q1l22]=max[0.107×13.21×0.452,0.5×13.21×0.152]=0.29kN·m σ=Mmax/W=0.29×106/42670=6.71N/mm2≤[f]=15.44N/mm2 满足要求! (2)、抗剪验算

Vmax=max[0.607q1l1,q1l2]=max[0.607×13.21×0.45,13.21×0.15]=3.607kN τmax=3Vmax/(2bh0)=3×3.607×1000/(2×40×80)=1.69N/mm2≤[τ]=1.78N/mm2 满足要求!

- 14 -

(3)、挠度验算

ν1=0.632q2l14/(100EI)=0.632×10.55×4504/(100×9350×1706700)=0.17mm≤[ν]=l/400=450/400=1.12mm

ν2=q2l24/(8EI)=10.55×1504/(8×9350×1706700)=0.04mm≤[ν]=l/400=150/400=0.38mm 满足要求!

(4)、支座反力计算

梁头处(即梁底支撑小梁悬挑段根部) 承载能力极限状态

Rmax=max[1.143q1l1,0.393q1l1+q1l2]=max[1.143×13.21×0.45,0.393×13.21×0.45+13.21×0.15]=6.79kN

同理可得,梁底支撑小梁所受最大支座反力依次为R1=R6=3.23kN,R2=R5=6.79kN,R3=R4=5.54kN 正常使用极限状态

R'max=max[1.143q2l1,0.393q2l1+q2l2]=max[1.143×10.55×0.45,0.393×10.55×0.45+10.55×0.15]=5.43kN

同理可得,梁底支撑小梁所受最大支座反力依次为R'1=R'6=2.76kN,R'2=R'5=5.43kN,R'3=R'4=4.41kN

6、主梁验算

主梁类型 可调托座内主梁根数 主梁抗弯强度设计值[f](N/mm) 主梁截面惯性矩I(cm) 42钢管 2 205 12.19 主梁材料规格(mm) 主梁弹性模量E(N/mm) 主梁抗剪强度设计值[τ](N/mm) 主梁截面抵抗矩W(cm) 322Ф48×3.5 206000 125 5.08 主梁自重忽略不计,因主梁2根合并,则抗弯、抗剪、挠度验算荷载值取半,计算简图如下: