火电厂原则性热力系统变工况计算

2020-02-20 22:53

摘 要

火电厂热系统工况发生变动时,将会引起整个热系统和全厂的热经济性指标发生变动。本设计主要内容为某660MW凝汽式机组全厂原则性热力系统变工况计算,根据给定的热力系统及其数据,在热力系统常规计算方法的基础下,计算额定功率下,切除最后一级高压加热器H1时的系统中各点汽水参数、流量和热经济指标,以及分析其经济性。根据设计工况与变工况两组数据的计算结果作为运行和调控的依据。

关键词:原则性 热力系统 变工况 常规法

I

Abstract

Thermal power plant thermal system conditions (parameters) change will cause the entire thermal system and heat the whole plant changes in economic indicators. The main elements of the design for a 660MW unit condensing steam plant thermal system in principle calculation of variable condition, according to a given thermal system and its data to calculate the rated power, when the removal of the last level at the time of high-pressure heater system H1 soft drinks all parameters, flow and thermal economic indicators. By ordinary methods and equivalent enthalpy drop method to compare the calculation of the two conditions of thermal economy, in order to provide the basis for the operation and regulation.

Key words :Principle Thermal System Changes the operating mode Equivalent enthalpy drop

II

目 录

第一章 绪 论 ....................................................................................................................................................... 1 第二章 热力系统原则性计算原理 ............................................................................................................... 2 1.1常规计算法 ....................................................................................................................................................... 2 1.2等效焓降法 ....................................................................................................................................................... 3 第三章 机组全厂原则性热力系统计算 ..................................................................................................... 5 3.1 热力系统与计算原始资料 .......................................................................................................................... 5 3.2 汽水平衡计算 ................................................................................................................................................. 9 3.3 汽轮机进汽参数计算 ................................................................................................................................... 9 3.4 辅助计算 ......................................................................................................................................................... 10 3.5 各加热器进、出水参数计算 ................................................................................................................... 11 3.6 高压加热器组抽汽系数计算 ................................................................................................................... 14 3.7 除氧器抽汽系数计算 ................................................................................................................................. 15 3.8 低压加热器组抽汽系数计算 ................................................................................................................... 16 3.9 凝汽系数计算 ............................................................................................................................................... 17 第四章 机组全厂原则性热力系统变工况计算 ..................................................................................... 19 4.1 原始工况计算 ............................................................................................................................................... 19 4.2 第一次迭代的预备计算 ............................................................................................................................ 22 4.3 第一次迭代计算 ........................................................................................................................................... 28 4.4 第二次迭代计算 ........................................................................................................................................... 34 4.5 第三次迭代计算 ........................................................................................................................................... 44 4.6 全厂热经济指标计算 .................................................................................................................................. 45 第五章 结 论 ..................................................................................................................................................... 47 谢 辞 ........................................................................................................................................................................ 48 参考文献 ................................................................................................................................................................. 49

1

第一章 绪 论

火电厂热系统的变工况是指系统的工作条件(参数)发生变动,偏离设计工况或都偏离某一基准工况。这种偏离大致辞有二种情况:一是对热系统的结构进行了某种局部改动;二是热系统本身的结构未加改动,但是系统运行条件发生了变化。前者的例子如去除某一级加热器运行等,不论哪一种形式的工况变动,结果都将引起整个热系统的参数的变化,从而导致机组的和全厂的热经济指标发生变动。

在电厂的设计和运行中,全厂热力计算主要解决两类问题:一是经计算给出若干工况下全厂的热经济性指标,如全厂发、供电煤耗率,全厂热效率,全厂节煤量等;二是为电厂的设计、运行、机组检修等提供基础数据,如汽轮机组以及各汽、水管道的汽水流量。

设计工况的指标是所有工况中最具有代表性的,因此设计工况下的全厂热力计算是最为普遍、也是最为基本的计算。在设计和最大工况下进行计算所得到的各部分汽水流量,是选择机组辅助热力设备和汽水管道的重要依据。在进行其他一些工况计算(即变工况计算)时设计工况的计算结果往往就为它们提供初始的计算依据。

热系统变工况计算的目的,是确定汽轮机在新的工况下各抽汽口和排汽端的蒸汽参数,以及回热给水系统各参数及流量,其实质是确定汽轮机的新的汽态膨胀过程线和系统参数。

热力系统的变工况计算是以级组(两个抽汽口之间的各级)为单位进行的。计算时只需要了解各抽汽口的参数变化而不必知道汽轮机各级详细工况。

较为精确的变工况计算是将系统本身的变工况和设备的变工况结合起来进行的。凝汽器的变工况计算已有较为精确的计公式,但回热加热器、除氧器的变工况则十分复杂,其变工况计算的模型至今尚不清楚。在计算精度要求不高,只需要大致了解工况变动的基本结果时,可以采用近似计算方法,即对于设备变工况后的参数变化,利用一些最简单的函数关系加以确定。这将大大简化计算所需要的原始资料和计算过程。本文的计算主要介绍此种方法。

1

第二章 热力系统原则性计算原理

火电厂热力系统计算的核心是对回热加热器的热平衡式进行求解,求得各抽汽系数,

然后根据汽轮发电机组的功率,求解汽轮机进汽量以及机组热经济指标(定功率计算)或者根据汽轮机的进汽量确定汽轮机发电机组的功率(定流量计算)。

回热机组原则性热力系统计算方法,有传统的常规计算方法以及等效焓降法、循环函数法等。常规计算通常有两种方法:串联法和并联法。对于热力系统热平衡方程组,用手工计算求解时,为了使计算的每一个方程只出现一个未知数,计算的次序是“由高到低”,即先从抽汽压力最高的加热器算起,依次逐个算至抽汽压力最低的加热器,因此称作串联法;用计算机计算时,可以对所有的能量平衡方程联立求解,一次即可获得全部未知数,故称作并联法;并联计算则需要求解多元线性方程组。

等效焓降法的最大特点是在系统的局部结构或者参数变动时,可以进行局部定量,而不需要像常规法那样重新进行整个系统的全部计算,因而给热系统的节能分析和节能改造带来很大的方便。但等效焓降运河的基本前提是各加热器的汽水参数维持设计值,如果这一条不能保证或难以忽略,则等效焓降法的计算结果会引起一定的误差。另外,如果除汽轮机的效率以外,还需要求出回热系统各汽水流量、汽水参数时,则仍需要按常规法计算方法求取。

等效焓降法作为热平衡计算方法时,其物理概念不及传统方法明显,计算过程亦并不简化,但作为一种热系统分析方法,它们都可避开与变动无关的计算,而直接得到经济性指标的计算结果,因而有独特的优越性。 1.1常规计算法

常规计算未能的实质,实际上是对由z个加热器热平衡方程式和一个凝汽器物质平衡式所组成的(z+1)个线性方程进行求解,可解出z+1个未知数(z个抽汽系统aj和一个凝汽系数aj和一个凝汽系数ac)。然后直接求出所需要的新汽耗量或机组功率、热经济性指标等。 1)串联计算

串联计算是指按照加热器压力“由高到低”的次序,依次对各个加热器进行热平衡、流量平衡计算,独立地求得各抽汽量或抽汽系数等未知量的方法。在计算过程中,有时需要进行局部的试算,在计算完毕后再加以检查修正,但总体上是顺序的、直接的计算。

串联计算可以避开解方程组的麻烦,既可用于手算,亦可用于计算机计算。当进行变工况计算时,、利用串联解法可借助计算机迭代计算容易将汽态参数的变化一并计算出来,这是其他计算方法所难以做到的。 2)并联计算(电算方法)

电算热力系统时,将z+1个方程排成矩阵来计算,可同时解出全部抽汽系数。为计算