火电厂原则性热力系统变工况计算(6)

2020-02-20 22:53

P3'?P4h4?h3?'(h3?h4,0)

P3?P4,0?3169.0?1.258?0.982(2941.72?2818.2)?3098.5.2kJ/kg

1.258?0.964第五抽汽口压力P5:

P5?P5,0D5/D5,0?0.416?1387107/1382014?0.425MPa

第五抽汽口蒸汽比焓h5

P4'?P5h5?h4?'(h4?h5,0)

P4?P5,0?3012.2?0.699?0.416(2821.8?2714.3)?2919kJ/kg

0.699?0.425第六抽汽口压力P6:

P6?P6,0D6/D6,0?0.226?1346109/1342105?0.234MPa

第六抽汽口蒸汽比焓h6

P5'?P6h6?h5?'(h5?h6,0)

P5?P6,0?2798.2?0.996?0.425(2719?2343)?2743.2kJ/kg

0.996?0.415第七抽汽口压力P7:

P7?P7,0D7/D7,0?0.109?1282901/1281023?0.113MPa

第七抽汽口蒸汽比焓h7

P6'?P7h7?h5?'(h6?h7,0)

P6?P7,0?2698.2?0.596?0.109(2719?2343)?2643.2kJ/kg

0.596?0.112第八抽汽口压力P7:

P8?P8,0D8/D8,0?0.0197?1125436/1122564?0.0201MPa

第八抽汽口蒸汽比焓h8

P7'?P8h8?h8?'(h7?h8,0)

P7?P8,0?2498.2?0.116?0.0197(2719?2343)?2443.2kJ/kg

0.116?0.0201

23

将上述的计算结果列于下表:

表4-7 抽汽压力及比焓值(供第一次迭代) 项 目 H1 H2 H3 H4 H5 抽汽压力Pj' 抽汽比焓hj 抽汽管道压损ΔPj 加热器侧压力Pj 饱和温度ts,j 出水温度tw,j '进水温度tw ,jH6 0.234 H7 0.113 H8 0.0201 5.986 3.785 1.783 0.987 0.425 3186.2 3059.2 3368.2 3098.8 2919.4 2743.2 2643.2 2443.2 0 5.986 272.9 274.6 242.7 0.1078 0.0816 0.03745 0.01537 0.00657 0.00346 0.00112 3.688 243.5 243.5 199.5 1.766 204.9 206.6 168.9 0.964 176.1 176.1 172.3 746.2 556.6 746.6 0.416 140.0 134.5 102.9 567.3 433.3 606.4 0.226 123.1 123.1 86.7 506.8 365.2 517.1 0.109 101.2 98.4 58.7 414.3 248.0 268.8 0.0197 59.1 56.3 33.1 238.0 141.1 161.7 出水比焓hw,j '进水比焓hw ,j1203.9 1056.3 733.5 1052.6 850.6 755.8 疏水比焓hd,j 1076.6 1056.3 890.1 2)加热器压力与饱和温度 第一抽汽口:因为高加H1切除,所以其相应的抽汽管道的压损为零,加热器压力等于抽汽压力抽气量为零。

第二抽汽口:原始工况抽汽管道压损ΔP2,0:

'ΔP2,0?P2,0?P2,0?3.785?3.6584?0.0851MPa

变工况后抽汽压损ΔP2

ΔP2?ΔP2,0(D21572112)?0.0851?()?0.1045MPa D2,01568954式中 D2——第二抽汽口抽汽流量 ,见表4-6; D2,0——迭代前第二抽汽口抽汽流量,见表4-4. 加热器压力P2:

P2?P2'?ΔP2?3.758?0.0851?3.697MPa

式中P2'——变工况后第二抽汽口压力,MPa。

由P2?3.679MPa,查水蒸气性质表,得加热器H2饱和温度ts,2:

ts,2?245.40C

24

第三抽汽口:原始工况抽汽管道压损ΔP3,0:

'ΔP3,0?P3,0?P3,0?1.783?1.776?0.027MPa

变工况后抽汽压损ΔP3

ΔP3?ΔP3,0(D31495440)?0.027?()?0.0816MPa D3,01492134加热器压力P3:

P3?P3'?ΔP3?1.783?0.027?1.756MPa

由P3?1.756MPa,查水蒸气性质表,得加热器H2饱和温度ts,3:

ts,3?204.90C

第四抽汽口:原始工况抽汽管道压损ΔP4,0:

'ΔP4,0?P4,0?P4,0?0.987?0.955?0.022MPa

变工况后抽汽压损ΔP4

ΔP4?ΔP4,0(D41451906)?0.022?()?0.0236MPa D4,01448936加热器压力P4:

P4?P4'?ΔP4?0.987?0.0236?0.964MPa

由P4?0.964MPa,查水蒸气性质表,得加热器H2饱和温度ts,4:

ts,4?176.10C

第五抽汽口:原始工况抽汽管道压损ΔP5,0:

'ΔP5,0?P5,0?P5,0?0.425?0.416?0.009MPa

变工况后抽汽压损ΔP5

ΔP5?ΔP5,0(D51387105)?0.009?()?0.011MPa D5,01382564加热器压力P5:

P5?p??2Δp2?0.425?0.011?0.414MPa

由P5?0.414MPa,查水蒸气性质表,得加热器H5饱和温度ts,5:

ts,5?140.00C

第六抽汽口:原始工况抽汽管道压损ΔP6,0:

'ΔP6,0?P6,0?P6,0?0.234?0.212?0.012MPa

变工况后抽汽压损ΔP6

ΔP6?ΔP6,0(D61346109)?0.012?()?0.015MPa D6,0134432525

加热器压力P6:

P6?P6'?ΔP6?0.234?0.0.015?0.219MPa

由P6?0.219MPa,查水蒸气性质表,得加热器H6饱和温度ts,6:

ts,6?123.10C

第七抽汽口:原始工况抽汽管道压损ΔP7,0:

'ΔP7,0?P7,0?P7,0?0.113?0.109?0.0042MPa

变工况后抽汽压损ΔP7

ΔP7 ?ΔP,0(D71282901)?0.0042?()?0.0046MPa D7,01281012加热器压力P6:

P7?P7'?ΔP7?0.1130?0.0046?0.1084MPa

由P7?0.1084MPa,查水蒸气性质表,得加热器H6饱和温度ts,6:

ts,7 ?101.20C

第八抽汽口:原始工况抽汽管道压损ΔP8,0:

'ΔP8,0?P8,0?P8,0?0.0201?0.189?0.0012MPa

变工况后抽汽压损ΔP8

ΔP8,0(8 ?ΔPD81282901)?0.0012?()?0.0013MPa D8,01281012加热器压力P6:

P8?P8'?ΔP8?0.0201?0.0012?0.0189MPa

由P8?0.0189MPa,查水蒸气性质表,得加热器H8饱和温度ts,8:

ts,8 ?59.10C

3)加热器出、进水温度,进、出水比焓 仍从第二级加热器H2算起: 出水温度tw,2?ts,2?0?243.5oC 出水比焓hw,2:

由高压加热器管组水侧压力Pw?21.47MPa,出水温度243.5oC查表得

hw,2?1056.4KJ/Kg

高压加热器H3:

出水温度tw,3 ?ts,3?δ?104.3?1.7?106.0oC 出水比焓hw,3:

由高压加热器管组水侧压力Pw?21.47MPa,出水温度206.6oC查表得 hw,3?890.1KJ/Kg

26

除氧器H4:

出水温度tw,3 ?ts,4?0?176.1oC hw,4?757.9KJ/Kg 低压加热器H5:

出水温度tw,5 ?ts,5?2.7?149.9oC 出水比焓hw,5:

由除氧器管组水侧压力Pw?0.916MPa,出水温度149.9oC查表得 hw,5?632.1KJ/Kg 低压加热器H5:

出水温度tw,5 ?ts,5?2.7?132.8oC 出水比焓hw,5:

由除氧器管组水侧压力Pw?2.758MPa,出水温度132.8oC查表得

hw,5?560.02KJ/Kg

低压加热器H6:

出水温度tw,6 ?ts,6?2.7?121.4oC 出水比焓hw,6:

由除氧器管组水侧压力Pw?2.758MPa,出水温度124.1oC查表得

hw,6?522.99KJ/Kg

进水比焓:

'hw?hw,3?850.6kJ/kg ,2进水温度:

'tw,2?tw,3?206.6℃

式中tw,3——第三级加热器的出水温度。

''同理可以计算出除第三级和第八级之外的其余各级加热器的进水温度tw,j进水比焓hw,j。

'第三级加热器的进水温度tw,3为给水泵的出水温度,因此不能套用上式可按下式直接求出''H3的进水比焓hw,3然后查出tw,3。

'hw,3?hw,3?Γpu?746.2?25.4?771.6kJ/kg

pu式中Γpu——给水泵比焓升,变工况时取常数Γ ? 25.4 kJ/kg

hw,3——除氧器饱和水比焓,hw,3 ?746.2 kJ/kg

'第八级加热器H8的进水温度tw变工况时不必计算这个,8为轴封加热器SG的出水温度。

值,直接由SG的热平衡计算得到SG的出水焓值hw,SG即可。 4)加热器疏水比焓 第二级加热器疏水比焓hd,2

'hd,2?hw,2?ΔhI2?956.3?17.9?972.2kJ/kg

27


火电厂原则性热力系统变工况计算(6).doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!

下一篇:玉溪市城市总体规划(2011-2030) - 图文

相关阅读
本类排行
× 注册会员免费下载(下载后可以自由复制和排版)

马上注册会员

注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。