立面图

四、面板验算

面板类型 面板抗弯强度设计值[f](N/mm) 2覆面木胶合板 15 面板厚度(mm) 面板弹性模量E(N/mm) 215 10000 取单位宽度1000mm,按四等跨连续梁计算,计算简图如下:

- 30 -

W=bh/6=1000×15×15/6=37500mm,I=bh/12=1000×15×15×15/12=281250mm q1=0.9max[1.2(G1k+ (G2k+G3k)×h)+1.4Q2k,1.35(G1k+

(G2k+G3k)×h)+1.4×0.7Q2k]×b=0.9max[1.2×(0.1+(24+1.5)×1.6)+1.4×2,1.35×(0.1+(24+1.5)×1.6)+1.4×0.7×2]×1=51.458kN/m

2334

q1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.6]×1=49.694kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/m q2=(G1k+ (G2k+G3k)×h)×b=[0.1+(24+1.5)×1.6]×1=40.9kN/m 1、强度验算

Mmax=0.107q1静L2+0.121q1活L2=0.107×49.694×0.1252+0.121×1.764×0.1252=0.086kN·m σ=Mmax/W=0.086×106/37500=2.304N/mm2≤[f]=15N/mm2 满足要求! 2、挠度验算

νmax=0.632q2L4/(100EI)=0.632×40.9×1254/(100×10000×281250)=0.022mm≤[ν]=l/250=125/250=0.5mm 满足要求! 3、支座反力计算

设计值(承载能力极限状态)

R1=R5=0.393 q1静l +0.446 q1活l=0.393×49.694×0.125+0.446×1.764×0.125=2.54kN R2=R4=1.143 q1静l +1.223 q1活l=1.143×49.694×0.125+1.223×1.764×0.125=7.37kN R3=0.928 q1静l +1.142 q1活l=0.928×49.694×0.125+1.142×1.764×0.125=6.016kN 标准值(正常使用极限状态)

R1'=R5'=0.393 q2l=0.393×40.9×0.125=2.009kN R2'=R4'=1.143 q2l=1.143×40.9×0.125=5.844kN R3'=0.928 q2l=0.928×40.9×0.125=4.744kN

五、小梁验算

小梁类型 小梁抗弯强度设计值[f](N/mm) 2方木 15.44 小梁材料规格(mm) 小梁抗剪强度设计值[τ](N/mm) 240×90 1.78 - 31 -

小梁弹性模量E(N/mm) 小梁截面惯性矩I(cm) 429350 243 小梁截面抵抗矩W(cm) 354 为简化计算,按四等跨连续梁和悬臂梁分别计算,如下图:

q1=

max{2.54+0.9×1.35×[(0.3-0.1)×0.5/4+0.5×(1.6-0.12)]+0.9max[1.2×(0.5+(24+1.1)×0.12)+1.4×2,1.35×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×max[0.6-0.5/2,(1.2-0.6)-0.5/2]/2×1,7.37+0.9×1.35×(0.3-0.1)×0.5/4}=7.4kN/m

q2=max[2.009+(0.3-0.1)×0.5/4+0.5×(1.6-0.12)+(0.5+(24+1.1)×0.12)×max[0.6-0.5/2,(1.2-0.6)-0.5/2]/2×1,5.844+(0.3-0.1)×0.5/4]=5.869kN/m 1、抗弯验算

Mmax=max[0.107q1l12,0.5q1l22]=max[0.107×7.4×0.62,0.5×7.4×0.152]=0.285kN·m σ=Mmax/W=0.285×106/54000=5.279N/mm2≤[f]=15.44N/mm2 满足要求!

- 32 -

2、抗剪验算

Vmax=max[0.607q1l1,q1l2]=max[0.607×7.4×0.6,7.4×0.15]=2.695kN τmax=3Vmax/(2bh0)=3×2.695×1000/(2×40×90)=1.123N/mm2≤[τ]=1.78N/mm2 满足要求! 3、挠度验算

ν1=0.632q2l14/(100EI)=0.632×5.869×6004/(100×9350×2430000)=0.212mm≤[ν]=l/250=600/250=2.4mm

ν2=q2l24/(8EI)=5.869×1504/(8×9350×2430000)=0.016mm≤[ν]=l/250=150/250=0.6mm 满足要求! 4、支座反力计算

梁头处(即梁底支撑小梁悬挑段根部) 承载能力极限状态

Rmax=max[1.143q1l1,0.393q1l1+q1l2]=max[1.143×7.4×0.6,0.393×7.4×0.6+7.4×0.15]=5.075kN

同理可得,梁底支撑小梁所受最大支座反力依次为R1=R5=3.137kN,R2=R4=5.075kN,R3=4.147kN

正常使用极限状态

R'max=max[1.143q2l1,0.393q2l1+q2l2]=max[1.143×5.869×0.6,0.393×5.869×0.6+5.869×0.15]=4.025kN

同理可得,梁底支撑小梁所受最大支座反力依次为R'1=R'5=2.773kN,R'2=R'4=4.025kN,R'3=3.275kN

六、主梁验算

主梁类型 可调托座内主梁根数 2钢管 1 205 10.78 主梁材料规格(mm) 主梁弹性模量E(N/mm) 主梁抗剪强度设计值[τ](N/mm) 主梁截面抵抗矩W(cm) 322Ф48×3 206000 125 4.49 主梁抗弯强度设计值[f](N/mm) 主梁截面惯性矩I(cm) 4 主梁自重忽略不计,计算简图如下: - 33 -

、抗弯验算

主梁弯矩图(kN·m)

σ=Mmax/W=0.355×106/4490=79.101N/mm2≤[f]=205N/mm2 满足要求! 、抗剪验算

主梁剪力图(kN)

max=7.475kN

- 34 -

1