LED灯测试报告 - 图文

2019-08-01 23:36

Usai Technology Services Co., Ltd.

Test Report EN 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaries EN 61347-2-13 Lamp controlgear Part 2: Particular requirements Section Thirteen – d.c. or a.c. supplied electronic controlgear for LED modules Testing laboratory ………………….. : Address ……………………………….. : Report by …………………….. : Address ……………………………….. : Applicant ……………………………… : Address ……………………………….. : Standard ………………………………. : EN 60598-2-1:1989 used in conjunction with EN 60598-1:2008/A11:2009 EN 61347-2-13:2006 used in conjunction with EN 61347-1:2008 Test Result ……………………………. : Complied with the standard EN 60598-2-1 & EN 61347-2-13 Type of test object ………………….. : LED tube light Trademark ……………………………. : Model/type reference ……………….. : HG-T10-1-1.2M,HG-T10-1-0.6M,HG-T8-1-0.6M,HG-T8-1-1.2M,HG-T10-3-0.6M,HG-T10-3-1.2M,HG-T10-3-1.5M Rating …………………………………. : Input: 100-240Vac, 50-60Hz, Con. 500mA Max Output: 25W Max Manufacturer …………………………. : Address ……………………………….. : Test item particulars : Equipment mobility ………………… : Fixed Operation condition ………………… : Continues Class of equipment ………………… : Class II Protection against ingress of water . : IPX0

Report No.: S1107787 Page 1 of 39

Usai Technology Services Co., Ltd.

Possible test case verdicts : test case does not apply to the test object …….. : N(.A.) test object does meet the requirement …….…… : P(ass) test object does not meet the requirement ……. : F(ail)

Name and address of the testing laboratory : Usai Technology Services Co., Ltd. 3rd Floor, Tiandi Industrial Building, North ChaGuang Rd, XiLi Town, NanShan, ShenZhen, 518055, China Tel : +86-755-26734311(5 lines); Fax : +86-755-26734059 ; e-mail : szusai@21cn.net Tested by : Approved by : Name and Title _ __ Signature Name and Title ___ __ Signature

Report No.: S1107787

Page 2 of 39

Usai Technology Services Co., Ltd.

General remarks: \Attachment: report. 1. Cover page 1 page \2. Photo documents 3 page the report. Throughout this report a point is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Until otherwise specified, all tests are done under normal ambient condition 25±5°C, RH:65±20% and air pressure of 860 mbar to 1060 mbar. Remark: Model Difference: All models are the identical except the model name and output power and Dimension. See the following form: Model Input Voltage (Vac) output Dimension (cm) Power (W) 20 9 9 20 9 20 25 T10 T10 T8 T8 T10 T10 T10 Con(mA)

HG-T10-1-1.2M 100-240 HG-T10-1-0.6M 100-240 HG-T8-1-0.6M HG-T8-1-1.2M 100-240 100-240 400 200 200 200 330 440 500 HG-T10-3-0.6M 100-240 HG-T10-3-1.2M 100-240 HG-T10-3-1.5M 100-240 Remark 2: Unless otherwise indicated, the tests were conducted on the models of HG-T10-3-1.5M.

Report No.: S1107787

Page 3 of 39

Usai Technology Services Co., Ltd.

EN 60598-2-1 Requirement GENERAL TEST REQUIREMENTS Information for luminaire design considered More sections applicable ....................................... : CLASSIFICATION Type of protection ................................................. : Degree of protection (Requirement: Ordinary) ...... : Luminaire suitable for direct mounting on normally flammable surfaces............................................... : Luminaire not suitable for direct mounting on normally flammable surfaces................................ : Luminaire for normal use ..................................... : Luminaire for rough service ................................. : MARKING Mandatory markings Position of the marking Format of symbols/text Additional information Language of instructions Combination luminaires Nominal frequency in Hz Operating temperature Symbol or warning notice Wiring diagram Special conditions Metal halide lamp luminaire – warning Limitation for semi-luminaires Power factor and supply current Remark

Clause 1.2 (0) 1.2 (0.1) 1.2 (0.3) 1.4 (2) 1.4 (2.2) 1.4 (2.3) 1.4 (2.4) 1.4 (2.5) 1.5 (3) 1.5 (3.2) 1.5 (3.3) 1.5 (3.3.1) 1.5 (3.3.2) 1.5 (3.3.3) 1.5 (3.3.4) 1.5 (3.3.5) 1.5 (3.3.6) 1.5 (3.3.7) 1.5 (3.3.8) 1.5 (3.3.9) Result P Standard EN 62471 Yes No Yes No P N P Class II IPX0 Yes Yes Yes Yes No No No No P P P N P N P English Not such type No outlet used P P P P P N P P N N N N N P P N N P P N N

1.5 (3.3.10) Suitability for use indoors 1.5 (3.3.11) Luminaires with remote control 1.5 (3.3.12) Clip-mounted luminaire – warning 1.5 (3.3.13) Specifications of protective shields 1.5 (3.3.14) Symbol for nature of supply 1.5 (3.3.15) Rated current of socket outlet 1.5 (3.3.16) Rough service luminaire Report No.: S1107787

Page 4 of 39

Usai Technology Services Co., Ltd.

EN 60598-2-1 Requirement Remark

Clause Result N N N N P P P P P 1.5 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments 1.5 (3.3.18) Non-ordinary luminaires with PVC cable 1.5 (3.3.19) Protecive conductor current in instruction if applicable 1.5 (3.3.20) Provide with information if not intended to be mounted within arms reach 1.5 (3.4) 1.6 (4) 1.6 (4.2) 1.6 (4.3) 1.6 (4.4) 1.6 (4.4.1) 1.6 (4.4.2) 1.6 (4.4.3) 1.6 (4.4.4) CONSTRUCTION Components replaceable without difficulty Wireways smooth and free from sharp edges Lampholders Integral lampholder Wiring connection Lampholder for end-to-end mounting Positioning - pressure test (N) ............................................... : After test the lampholder comply with relevant standard sheets and show no damage After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation - bending test (N) ................................................. : After test the lampholder have not moved from its position and show no permanent deformation Peak pulse voltage Centre contact Parts in rough service luminaires resistant to tracking Lamp connectors Caps and bases correctly used Starter holders Starter holder in luminaires other than class II Starter holder class II construction Test with water Test with hexane Legible after test Label attached The marking is no curling, no removable and legible N P N N P N N N N N 1.6 (4.4.5) 1.6 (4.4.6) 1.6 (4.4.7) 1.6 (4.4.8) 1.6 (4.4.9) 1.6 (4.5) N N N N N N N N N N

Report No.: S1107787

Page 5 of 39


LED灯测试报告 - 图文.doc 将本文的Word文档下载到电脑 下载失败或者文档不完整,请联系客服人员解决!