Usai Technology Services Co., Ltd.
EN 60598-2-1 Requirement - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc. Thermal test (normal operation) Thermal test (abnormal operation) Thermal test (failed lamp control gear condition): Remark (see Annex 2) (see Annex 2)
Clause 1.12 (12.4) 1.12 (12.5) 1.12 (12.6) Result N N P P P P N ? ? N ? N N N N 1.12 (12.6.1) Through wiring or looping-in wiring loaded by a current of (A) ........................................................ : - case of abnormal conditions .............................. : - electronic lamp control gear - measured winding temperature (?C): at 1,1 Un . : - measured mounting surface temperature (?C) at 1,1 Un ................................................................... : - calculated mounting surface temperature (?C) . : - track-mounted luminaires 1.12 (12.6.2) Temperature sensing control 1.12 (12.7) - case of abnormal conditions .............................. : - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature (?C)... : - track-mounted luminaires ? N N N N N N N N Thermal test (failed lamp control gear in plastic luminaires): 1.12 (12.7.1) Luminaire without temperature sensing control 1.12 (12.7.1.1) Luminaire with fluorescent lamp ≤ 70W Test method 12.7.1.1 or Annex V ......................... : Test according to 12.7.1.1: - case of abnormal conditions - Ballast failure at supply voltage (V) ................... : - Components retained in place after the test - Test with standard test finger after the test Test according to Annex V: - case of abnormal conditions - measured winding temperature (?C): at 1,1 Un .. : ? N ? ? N N N ? ?
Report No.: S1107787
Page 16 of 39
Usai Technology Services Co., Ltd.
EN 60598-2-1 Requirement Remark
Clause 1.12 (12.7.1.2) 1.12 (12.7.1.3) Result ? ? N - measured temperature of fixing point/exposed part (?C): at 1,1 Un ....................................................... : - calculated temperature of fixing point/exposed part (?C) ....................................................................... : Ball-pressure test: - part tested; temperature (?C) ............................. : - part tested; temperature (?C) ............................. : N N N ? ? ? ? N Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA - case of abnormal conditions - measured winding temperature (?C): at 1,1 Un .. : - measured temperature of fixing point/exposed part (?C): at 1,1 Un ....................................................... : - calculated temperature of fixing point/exposed part (?C) ....................................................................... : Ball-pressure test: - part tested; temperature (?C) ............................. : - part tested; temperature (?C) ............................. : N N N ? N N N Luminaire with short circuit proof transformers ≤ 10 VA - case of abnormal conditions - Components retained in place after the test - Test with standard test finger after the test 1.12 (12.7.2) Luminaire with temperature sensing control 1.13 (9) 1.13 (9.2) - thermal link - manual reset cut-out - auto reset cut-out - case of abnormal conditions - highest measured temperature of fixing point/exposed part (?C):........................................ : Ball-pressure test: - part tested; temperature (?C) ............................. : - part tested; temperature (?C) ............................. : Yes Yes Yes No No No ? ? ? ? ? N N N P N ?
RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE Tests for ingress of dust, solid objects and moisture: - classification according to IP .............................. : IPX0 Report No.: S1107787
Page 17 of 39
Usai Technology Services Co., Ltd.
EN 60598-2-1 Requirement - mounting position during test ............................. : - fixing screws tightened; torque (Nm) .................. : - tests according to clauses .................................. : - electric strength test afterwards a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on current-carrying parts or where it could become a hazard d) i) For luminaires without drain holes – no water entry Remark
Clause 1.13 (9.3) Result ? ? ? N N N N N N N N N N P P P ? ? N P P P P d) ii) For luminaires with drain holes – no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (IP 2X) f) no entry into enclosure (IP 3X and IP 4X) f) no contact with live parts (IP3X and IP4X) Humidity test 48 h 25℃;93% RH 1.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH 1.14 (10.2.1) Insulation resistance test Cable or cord covered by metal foil or replaced by a metal rod of mm ? ............................................... : Insulation resistance (M?) SELV: - between current-carrying parts of different polarity .............................................................................. : - between current-carrying parts and mounting surface .................................................................. : - between current-carrying parts and metal parts of the luminaire ......................................................... : Other than SELV: - between live parts of different polarity ................ : - between live parts and mounting surface ........... : - between live parts and metal parts ..................... : - between live parts of different polarity through action of a switch .................................................. : >20MΩ >20MΩ P P N N P 1.14 (10.2.2) Electric strength test Dummy lamp N
Report No.: S1107787
Page 18 of 39
Usai Technology Services Co., Ltd.
EN 60598-2-1 Requirement Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V): SELV: - between current-carrying parts of different polarity .............................................................................. : - between current-carrying parts and mounting surface .................................................................. : Remark
Clause 1.14 (10.3) 1.15 (13) Result N N N N N N N P - between current-carrying parts and metal parts of the luminaire ......................................................... : Other than SELV: - between live parts of different polarity ................ : - between live parts and mounting surface ........... : - between live parts and metal parts ..................... : - between live parts of different polarity through action of a switch .................................................. : Leakage current (mA) ........................................... : RESISTANCE TO HEAT, FIRE AND TRACKING 1480V 3710V 3710V 0.005mA<0.5mA P P N N P P P 1.15 (13.2.1) Ball-pressure test: - part tested; temperature (?C) ............................. : - part tested; temperature (?C) ............................. : P P N 1.15 (13.3.1) Needle flame test (10 s): - part tested .......................................................... : - part tested .......................................................... : N N P 1.15 (13.3.2) Glow-wire test (650?C):
- part tested .......................................................... : - part tested .......................................................... : P N N 1.15 (13.4.1) Tracking test: part tested ...................................... :
Report No.: S1107787
Page 19 of 39
Usai Technology Services Co., Ltd.
ANNEX 1: components object/part No. manufacturer/ type/model trademark Enclousre P technical data standard mark(s) of conformity - UL E195100
TEIJIN LV-2250(#)(f2) V-0, 115℃ POLYCARBONATE SINGAPORE PTE LTD various various various various various various V-0, 105℃ min PCB Internal wire - UL UL Test by appliance 22 AWG, 80℃ min - Input: 100-240Vac, - 50-60Hz, Con. 500mA Max Output: 25W Max. AC-DC controlgear temperature (?C) of part Model: HG-T10-3-1.5M Input wire Enclosure inside Enclosure outside AC-DC controlgear
ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference .................................................... : Lamp used ........................................................... : Lamp control gear used ....................................... : Mounting position of luminaire ............................. : Supply wattage (W) ............................................. : Supply current (A) ................................................ : Calculated power factor ....................................... : - - Normal use -- -- -- P ? ? ? ? ? ? ? ? ? ? ? ? ? Table: measured temperatures corrected for ta = 25 ?C: - abnormal operating mode ................................. : - test 1: rated voltage ........................................... : Normal .240Vac , - test 2: 1,06 times rated voltage or 1,05 times rated 254.4Vac wattage ................................................................ : - test 3: Load on wiring to socket-outlet, 1,06 times -- voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated 252Vac wattage ................................................................ : Through wiring or looping-in wiring loaded by a current of A during the test ................................. : Clause 12.4 – normal test 1 test 2 test 3 limit -- Clause 12.5 – abnormal test 4 limit 61.5 76.2 70.2 62.3 79.4 71.4 -- -- -- 80 -- 75 63.4 79.5 72.3 80 -- 75 Report No.: S1107787
Page 20 of 39