LED灯测试报告 - 图文(6)

2019-08-01 23:36

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test Fault conditions: capacitors, resistors or inductors without proof of compliance with relevant specifications have been short-circuited or disconnected Result - Remark (see appended table) Verdict P - (14.1) Short-circuit of creepage distances and clearances if less than specified in clause 16 in Part 1 (except between live parts and accessible metal parts) Distances on printed boards provided with coating according to IEC 60664-3 Short-circuit or interruption of semiconductor devices (see appended table) N N P N P P P P N - (14.2) - (14.3) - (14.4) - (14.5) 15 Short-circuit across insulation consisting of lacquer, enamel or textile Short-circuit across electrolytic capacitors (see appended table) During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite After the tests the insulation resistance with d.c. 500 V (M?) are ? 1 M? ....................................... : More than 20M? During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite Temperature declared thermally protected controlgear fulfil the requirements in Annex C TRANSFORMER HEATING Windings of separating transformer in a SELV-equivalent controlgear fulfil the requirements according to 7.1 and 11.2 of IEC 60065 Temperatures do not exceed the changed values of the values in column 2 of Table 3 of IEC 60065, in respect to relevant ambient temperature at tc, under normal operation Temperatures do not exceed the changed values of the values in column 3 of Table 3 of IEC 60065, in respect to relevant ambient temperature at tc, under abnormal conditions of Cl. 16 and fault conditions of Cl. 14 Ambient temperature at tc ................................... : 50℃ P P 15.1 P 15.2 P

? Report No.: S1107787

Page 26 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test ABNORMAL CONDITIONS Result - Remark Verdict P P ? N N N N P P P P P 16 16.1 Safety not impaired when ballast is operated at any voltage between 90% and 110% of rated voltage Controlgear which are of the constant voltage output type a) No LED module inserted b) Double LED modules or equivalent load connected to the output terminals c) Output terminal short-circuited (20 cm and 200 cm or declared length ) During and at the end of the tests no defect impairing safety, nor any smoke or flammable gases produced Control gear which are of the constant current output type: a) No LED module connected b) Double the LED modules or equivalent load connected in series to the output terminals c) Output terminal short-circuited (20 cm and 200 cm or declared length ) 16.2 During and at the end of the tests no defect impairing safety, nor any smoke or flammable gases produced 17 (15) - (15.1) - (15.2) CONSTRUCTION Wood, cotton, silk, paper and similar fibrous material not use as insulation Printed boards used as internal connections complies with clause 14 of IEC 61347-1 Socket-outlet in the output circuit does not accept plugs complying with IEC 60083 and IEC 60906 No plug P P P N N No plug Not possible to engage plugs accepted by socket-outlet in the output circuit with socket-outlets complying with IEC 60083 and IEC 60906 18 (16) CREEPAGE DISTANCES AND CLEARANCES Creepage distances and clearances according to Table 3 and 4, as appropriate Printed boards see clause 14 of IEC 61347-1 (see appended table) P P P Report No.: S1107787

Page 27 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test Insulating lining of metallic enclosures Result - Remark Verdict N 19 (17) (4.11) (4.11.1) (4.11.2) (4.11.3) (4.11.4) (4.11.5) (4.12) (4.12.1) (4.12.2) (4.12.3) (4.12.4) (4.12.5) 20 (18) (18.1) (18.2) (18.3) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS Screws, current-carrying parts and connections in compliance with IEC 60598-1 (clause numbers between parentheses refer to IEC 60598-1) Electrical connections: Contact pressure Screws: - self-tapping screws - thread-cutting screws - at least two self-tapping screws Screw locking: - spring washer - rivets Material of current-carrying parts No contact to wood Mechanical connections and glands: Mechanical stress Screws not made of soft metal Screws of insulating material Torque test: part; torque (Nm) ............................ : Screw diameter < 3 mm screwed into metal Void Locked connections Screwed glands: force (N) ................................... : No wood P P P P P P N N P P P P N P P N N N N ? P N RESISTANCE TO HEAT, FIRE AND TRACKING Parts of insulating material retaining live parts in position, ball-pressure test: - part; test temperature (?C) ................................ : Bobbin, PCB, enclosure P P P P N Printed boards in accordance with IEC 60249-1, 4.3 External parts of insulating material preventing electric shock glow-wire test 650 ?C Report No.: S1107787

Page 28 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test Result - Remark Verdict P P P N (18.4) (18.5) 21 (19) - (20)

Parts of insulating material retaining live parts in position, needle-flame test 10 s: - flame extinguished within 30 s - no flaming drops igniting tissue paper Tracking test RESISTANCE TO CORROSION Rust protection: - test according 4.18.1 of IEC 60598-1 - adequate varnish on the outer surface P P P P NO-LOAD OUTPUT VOLTAGE No load output voltage not differ more than 10 % from rated voltage N N Report No.: S1107787

Page 29 of 39

Usai Technology Services Co., Ltd.

TABLE:14 Part DB1 tests of fault conditions Fault condition Result Short Fuse open immediately. Insulation resistance: Pass, Electric strength test: Pass CX1 Short Fuse open immediately. Insulation resistance: Pass, Electric strength test: Pass Output Short Unit shut down, no damage, insulation resistance: Pass, terminal Electric strength test: Pass. Transformer Short Unit shut down, no damage, insulation resistance: Pass, secondary Electric strength test: Pass. U1 primary Short Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. U1 primary Open Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. U1 secondary Short Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. U1 secondary Open Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. D1 Short Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. D2 Short Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. R30 Short Normal operation. no damage, insulation resistance: Pass, Electric strength test: Pass. U2 Pin6-8 Short Normal operation. no damage, insulation resistance: Pass, Electric strength test: Pass. Q1 D-G Short Fuse open immediately. insulation resistance: Pass, Electric strength test: Pass. Q1 D-S Short Fuse open immediately. insulation resistance: Pass, Electric strength test: Pass. Q1 G-S Short Unit shut down, no damage, insulation resistance: Pass, Electric strength test: Pass. 18 (16) TABLE: creepage distances and clearances Minimum distances for a.c. (50/60 Hz) sinusoidal voltages RMS working voltage (V) not exceeding 50 150 1 minimum distances between live parts of N N different polarity. Specify the value measured. 2 minimum distances between live parts and N N accessible parts which are permanently fixed to the ballast, including screws or devices for fixing covers or fixing the ballast to its support. Specify the value measured. - required creepage distances (mm), 0,6 1,4 insulation PTI ? 600 - required creepage distances (mm), 1,2 1,6 insulation PTI < 600 - required clearances (mm) 0,2 1,4 P 1000 N N Hazard No No No No No No No No No No No No No No No 250 See below See below 500 N N 750 N N 1,7 2,5 1,7 3 5 3 4 8 4 5,5 10 5,5

Report No.: S1107787

Page 30 of 39