LED灯测试报告 - 图文(5)

2019-08-01 23:36

Usai Technology Services Co., Ltd.

61 67 66.4 71.1 86 83.3 82.3 83.7 97.7 94.7 90.6 81.1 78.8 76.8 60 78.8 77.7 74 73 50 62.4 68.8 68.3 72.3 88.1 84.8 83.7 85.1 99.2 96.5 92.5 83.7 81.1 79.8 63.1 81.2 80.4 75.2 74.3 50 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 105 130 130 105 120 105 105 130 130 110 110 100 130 130 80 110 110 95 95 -- 63.1 69.4 70.7 74.3 89.6 87.7 86.1 86.7 100.4 99.2 95 86.3 82.2 81.6 65.2 82.1 81.8 76.7 75.5 50

Input wire L1 winding L2 winding X-cap.(CX1) Y-cap. (CY1) E-cap. (C2) E-cap. (C3) PCB near DB1 PCB near Q1 Transformer winding (T1) pri. Transformer core (T1) Opto-couple (U1) PCB near Transformer T1 PCB near D1 Output wire Enclosure inside, near TF1 Enclosure inside, near TF1 side Top enclosure outside, near TF1 Side enclosure outside, near TF1 Ambient

105 130 130 105 120 105 105 130 130 110 110 100 130 130 80 110 110 95 95 --

Report No.: S1107787

Page 21 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test General requirements Result - Remark Verdict P P P 4 (4) 6 (6) 7 7.1 (7.1) Compliance of independent controlgear enclosure Compliance checked with EN 60 598-1 Independent SELV controlgear comply with Annex I (see Annex I) CLASSIFICATION Independent controlgear ...................................... : Built-in controlgear .............................................. : Integral controlgear ............................................. : SELV-equivalent or isolating controlgear ............. : Auto-wound controlgear ....................................... : Independent SELV controlgear ............................ : Yes Yes Yes Yes Yes Yes No No No No No No P ? ? ? ? ? ? MARKING Mandatory markings: - mark of origin - model number, type reference .......................... : - symbol for independent controlgear, if applicable - correlation between interchangeable parts and controlgear marked - rated supply voltage (V) .................................... : - earthing symbol - wiring diagram HG-T10-1-1.5M No user replaceable parts in the product. Input: 100-240Vac, 50-60Hz, Con. 400mA Output: 25W Wiring diagram of terminal connection is provided in the label. 65℃ ta=50℃ No No P P P P N P P N P P P ? ? P P N - value of tc - symbol for declared temperature Constant voltage type: Yes - rated output voltage (V) ........................................ : Yes Constant current type: - rated output current (A) ..................................... : - rated maximum output voltage (V) .................... : - indication if for LED modules only 500mA Max 36V dc Report No.: S1107787

Page 22 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test Information to be provided, if applicable: - declaration on protection against accidental contact - cross-section of conductors (mm2) ................... : - number, type and wattage of lamp(s) - directly mains-connected windings - SELV-equivalent controlgear Marking durable and legible Result - Remark Verdict P 7.2 (7.1) - (7.2) 8 (10) - (10.1) - (A2) - (A2) - (A3) - (10.1) - (10.2) 8.1 (-) P N P P P P P Rubbing 15 s water, 15 s petroleum; marking legible Compliance checked. PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS Controlgear protected against accidental contact with live parts P P P P P P P P The current flowing between the part concerned and earth is measured and does not exceed 0,7 mA Measured max. 0.3mA (peak) (peak) or 2 mA d.c. ................................................. : For frequencies above 1 kHz, the current does not exceed 0,7 mA (peak) multiplied by the value of the 10KHz frequency in kilohertz or 70 mA (peak) ................... : The voltage between the part concerned and any accessible part is measured and does not exceed Measured max. 20Vpeak. 34 V (peak) ............................................................... : Lacquer or enamel not used for protection or insulation Adequate mechanical strength on parts providing protection Capacitors > 0,5 ?F: voltage after 1 min (V): < 50 V : Measured 0.6V SELV-equivalent controlgear accessible parts are insulated from live parts by double or reinforced insulation according 8.6 and 13.1 in IEC 60065 Input circuit is isolated from output circuit by double or reinforced insulation. See appended table 18(16) for detail. Lead input/output wires provided, the insulation between live parts and accessible parts shall be evaluated during final system assembly. P 8.2 (-) Exposed terminals of SELV or SELV-equivalent controlgear are allowed if: - the rated or maximum output voltage does not exceeding 25 V r.m.s. - the no-load output voltage does not exceed 30 V No exposed terminals N Report No.: S1107787

Page 23 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test r.m.s. or 33 √2 V peak Result - Remark Verdict Insulated terminals if rated output voltage >25 V One capacitor Y1 or two capacitors Y2 of the same values used in series between SELV or SELV-equivalent output and primary circuits - Capacitor complying with IEC 60384-14 - Other components bridging the separating transformer complying with EN 60065, clause 14 One Y1 capacitor (CY1)complying with IEC 60384-14 is connected between primary circuit and secondary circuit. P P 9 (8) 10 (9) PROVISION FOR EARTHING External metal parts connected to the earthterminal: - compliance with 7.2.1 in IEC 60598-1 Test with a current of 10 A between earthing terminal and each of the accessible metal parts; measured resistance (?): < 0,5 ? ....................... : Protective earth, symbol Terminal complying with clause 8 in Part 1 N N N N N N N N N N N N TERMINALS Screw terminals: compliance with Section 14 of IEC Compliance checked. 60598-1 Screwless terminals: compliance with Section 15 of IEC 60598-1 P P N N N N Locked against loosening and not possible to loosen by hand Not possible to loosen clamping means unintentionally on screwless terminals Earthing via means of fixing Earthing terminal only used for the earthing of the control gear All parts of material minimizing the danger of electrolytic corrosion Made of brass or equicvalent material Contact surface bare metal Conductors by tracks on printed circuit boards: - a.c. current of 25 A for 1 min between earthing terminal and accessible metal parts Independent controlgear. Report No.: S1107787

Page 24 of 39

Usai Technology Services Co., Ltd. EN 61347-2-13 Clause Requirement + Test - compliance with clause 7.2.1 in IEC 60598-1 Result - Remark Verdict N 11 (11) 12 (12) MOISTURE RESISTANCE AND INSULATION After storage 48 h at 91-95% relative humidity and 20-30 ?C measuring of insulation resistance with d.c. 500 V (M?): ? 2 M? for basic insulation ....................................... : Between difference polarity measured: >20 M? Between live parts and metal enclosure measured:>20 M? ? 4 M? for double or reinforced insulation ............... : Between input circuits and output circuits measured: >20 M? Adequate insulation between input and output Input terminals are separated terminals not bounded together in SELV-equivalent from output terminals by double controlgear or reinforced insulation. P P P P P ELECTRIC STRENGTH Immediately after clause 11 electric strength test for 1 min Working voltage ? 42 V, test voltage 500 V Basic insulation, 2U + 1000 V Supplementary insulation, 2U + 1750 V Double or reinforced insulation, 2U + 2750 V No flashover or breakdown P P N P P P P P P Working voltage > 42 V ? 1000 V, test voltage (V): 1480V 2230V 3230V Windings in separating transformers in SELV-equivalent control gear according to 14.3.2 of EN 60065 13 (13) 14 (14) THERMAL ENDURANCE FOR WINDINGS (Not applicable) N FAULT CONDITIONS When operated under fault conditions the controlgear: - does not emit flames or molten material - does not produce flammable gases P P P P P N - protection against accidental contact not impaired Thermally protected controlgear does not exceed the marked temperature value Report No.: S1107787

Page 25 of 39