5:57 6:16 6:36 6:57 7:16 7:36 7:57 8:16 8:36 8:57 9:16 9:36 9:38 9:57 10:16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3000 5.9 471.0 0.5 444.5 42.2 -0.3 -0.3 12.0 12.1 3000 6.2 477.8 0.5 449.7 41.2 -0.4 -0.3 11.3 11.7 3000 6.6 486.5 0.5 456.6 47.0 -0.4 -0.3 19.2 19.3 3000 5.8 494.2 0.5 465.2 50.2 -0.3 -0.3 30.3 30.5 3000 8.8 515.7 0.6 485.9 87.6 5.7 7.9 99.7 99.3 3000 8.6 507.5 0.5 487.9 64.8 -0.4 -0.3 57.9 58.1 3000 9.0 504.9 0.5 487.0 80.0 3.4 3000 9.4 510.1 0.6 492.1 80.4 7.3 3000 10.7 506.6 0.7 492.1 80.5 9.3 3.4 64.0 64.0 6.8 99.5 99.5 8.9 99.6 99.3 3000 10.7 506.7 0.9 488.7 80.7 13.0 12.1 99.7 99.4 3000 11.3 511.8 0.9 486.9 80.7 12.7 11.6 99.7 99.4 3000 11.3 517.8 1.0 492.9 80.5 13.4 12.5 99.7 99.4 3000 11.3 517.8 0.9 492.9 80.6 12.9 11.9 99.8 99.3 3000 11.3 521.3 0.9 497.2 80.6 12.7 11.7 99.9 99.5 3000 11.4 520.4 0.9 497.2 80.6 12.0 16.0 99.6 99.5 10:36 47.5 3000 11.3 523.0 0.9 498.9 80.6 14.0 13.0 99.6 99.5 10:57 11:00 17:16 195 194 449 3000 12.0 517.8 1.2 500.6 0.0 -0.3 -0.3 0.7 3001 11.4 517.0 1.2 499.8 0.1 -0.3 -0.4 0.7 3002 19.4 534.6 2.8 536.6 0.1 -0.3 -0.3 0.8 0.6 0.6 0.6 (八). 汽轮机冲转
本次机组启动于8月16日3:25达到冲转参数,参数如下: 高压缸调节级金属温度:54℃;主蒸汽温度:390℃;主蒸汽压力:3.3MPa;再热蒸汽温度:379℃;再热蒸汽压力:0.337MPa;汽缸膨胀(左/右):3.71mm/3.51mm;高压胀差:3.11mm;低压胀差:7.8mm;润滑油温:38℃;润滑油压:0.10MPa;机组背压:13KPa;盘车电流:36A;偏心:96μm(就地实测25μm)。
3:33冲转升速至400rpm,打闸进行汽轮机听音摩检,汽机内部无异音。
3:46汽轮机中速2000rpm,机组振动最大为2瓦X向115μm,Y向135μm。
4:54中速暖机结束,继续升速,1瓦、2瓦轴振逐渐减小。 4:57机组定速,振动最大为1瓦X向80μm。 (汽机冲转过程参数见附件五) (九). 蒸汽管路吹扫
为防止氧化皮脱落堵管,本次启动制定了详细的蒸汽管路吹扫计划,通过调整高低压旁路及启动旁路,控制蒸汽流量,达到带走脱落氧化皮的目的,同时为#1机组启动吹扫总结经验。
为避免因吹扫后系统参数较高而汽机参数较低需重新降参数,本次启动采用先冲转暖机,后进行管路吹扫,然后并网的操作顺序,有效地避免了启动过程汽温汽压的交替波动。 (十). 机组并网
8月16日09:09,#2发电机首次启励,启励后DCS画面上显示发电机转子空载电压147V,转子空载电流1413A,发电机定子电压显示为0V。就地检查发电机出口PT确在工作位,动静触头接触良好,检查发电机出口PT二次小开关均在合闸位,在发电机出口PT根部测量发电机出口PT二次回路却无电压。检查发电机出口PT一、二次回路均未发现其他异常。
09:24,灭磁,就地检查发电机出口PT一、二次回路均未发现其他异常。09:48,#2发电机进行第二次启励,启励后DCS画面上显示发电机转子空载电压123V,转子空载电流1398A,发电机定子电压显示为20V,进行发电机出口PT一、二次回路检查,均未发现异常。10:09,灭磁。10:27,#2发电机进行第三次启励,启励后DCS画面上显示发电机转子空载电压123V,转子空载电流1391A,发电机定子电压显示为20V。10:34,#2发电机并网成功。#2发电机首次启励后发电机定子无电压的原因正在分析中。 (十一).
机组升负荷过程中机组振动情况
并网后1、2瓦轴振逐渐增大,以1瓦X向轴振、2瓦瓦振最为明显,其余各瓦振动均在80μm以下。当负荷升至430MW时机组振动1瓦X向轴振达到100μm,负荷升至480MW时1瓦X向轴振达到120μm,立即停止升负荷。(并网带负荷过程中振动变化见附件六、机组带负荷后胀差变化趋势见附件七):
并网带负荷过程中机组振动趋势表:
转速(rpm) 主蒸汽温度再热蒸汽温度调节级蒸汽温调节级金属温主蒸汽压力1瓦X向轴振1瓦Y向轴振(μm) 2瓦X向轴振(μm) 2瓦Y向轴振(μm) 机组负荷(MW) 时间 (℃) (℃) 度(℃) 度(℃) (MPa) (μm) 10:30 3000 522.6 499.5 293.8 298.1 11.3 70.7 67.5 46.3 55.9 1.4 10:32 3000 523.4 499.0 295.0 298.9 11.4 72.8 66.0 46.3 57.9 1.5 10:34 3000 523.4 498.2 296.5 299.8 11.4 73.2 65.9 48.3 53.9 19.7 10:36 3000 522.6 496.5 305.1 300.7 11.3 78.7 67.0 48.3 54.4 47.5 10:57 3000 517.4 498.8 450.1 414.7 11.5 79.7 71.0 44.3 41.4 194.1 11:16 3001 525.2 498.4 468.5 449.3 12.1 77.2 68.9 49.3 46.9 217.2 11:35 2998 541.5 510.1 491.4 470.0 11.8 83.2 70.5 48.3 49.9 257.3 11:56 3002 548.4 515.4 507.8 489.8 12.9 87.3 73.4 49.3 48.9 321.1 12:15 3002 550.9 523.5 509.5 501.8 13.5 94.2 77.0 51.5 53.9 347.1 12:35 3002 549.2 533.1 511.5 506.1 15.8 94.7 78.9 54.8 53.9 369.6 12:56 3002 541.5 528.8 494.0 491.5 18.3 97.3 77.4 56.8 55.9 402.3 13:15 3002 541.5 533.0 492.3 487.2 19.4 97.3 79.5 57.8 59.9 431.5 13:36 3001 546.6 538.5 503.8 489.8 20.7 115.3 86.0 50.8 72.9 501.1 13:55 3002 548.4 540.1 498.9 489.8 20.2 115.8 84.4 59.3 72.9 481.4 14:16 3001 552.7 546.4 504.9 492.4 20.3 121.3 85.5 51.8 72.3 478.2 14:34 3002 552.7 553.7 504.9 495.1 20.5 126.3 87.0 51.4 75.0 480.3 14:35 3002 552.7 553.4 504.9 495.1 20.6 125.2 84.0 51.3 69.9 480.9 14:37 3002 550.9 553.0 504.0 495.1 20.5 120.6 85.4 54.8 75.0 480.3 14:51 3002 552.7 554.3 505.2 496.0 20.5 112.3 83.5 52.3 72.0 479.0 14:53 2998 553.5 554.8 505.5 496.0 20.4 118.3 82.4 55.8 72.0 480.1 15:07 3002 552.7 554.3 503.8 496.9 20.8 122.2 88.1 53.3 70.9 479.6 15:09 3002 553.5 554.4 504.3 495.8 20.8 116.3 83.5 54.3 73.9 480.3 15:10 3002 554.4 554.3 505.2 495.8 20.8 114.8 85.5 51.8 76.0 477.4 15:12 3002 553.5 554.0 505.7 495.8 20.8 117.3 85.5 51.8 74.5 483.5 15:14 3002 553.5 554.4 505.2 495.8 20.7 129.8 83.5 51.3 74.5 484.4 15:16 3002 551.8 554.1 504.9 495.8 20.6 123.3 90.0 56.8 75.5 479.9 15:17 3002 550.1 553.4 503.5 495.8 20.5 115.3 84.0 50.4 75.4 480.6 15:19 3002 550.9 554.3 503.5 495.8 20.2 121.3 85.0 54.7 74.3 479.8 15:21 3002 556.1 556.6 506.0 495.8 20.2 119.8 83.0 52.3 72.4 480.0 15:23 3002 556.1 557.4 508.5 495.8 20.3 120.3 86.1 51.3 73.4 480.5 15:24 3002 552.7 556.3 506.9 495.8 20.2 121.3 86.4 53.8 75.5 479.5 15:26 3002 550.1 555.3 504.9 496.7 20.2 121.8 85.0 50.3 77.4 480.5 15:28 2998 550.1 556.1 504.3 496.7 20.2 120.3 83.0 52.8 73.4 480.0 15:30 3002 552.7 557.1 505.5 496.7 20.1 119.7 83.9 51.3 73.4 480.3 并网升负荷期间胀差、热膨胀、调节级金属温度列表:
汽轮机时间 转速(rpm) 机组负荷(MW) 主蒸汽温度(℃) 主蒸汽压力(MPa) 再热蒸汽温度再热蒸汽压力高压缸胀差低压缸胀差汽缸膨胀左汽缸膨胀右调节级金属温(℃) (MPa) (mm) (mm) (mm) (mm) 度(℃) 10:33 3000 10:36 3000 1.3 523.4 11.4 499.4 0.9 5.3 12.7 16.3 16.2 298.1 47.5 522.6 11.3 498.8 0.9 5.3 12.7 16.3 16.3 298.9 10:38 3000 66.3 520.0 11.3 496.5 0.6 5.4 12.8 16.4 16.5 300.7 10:40 3000 149.1 520.0 11.0 496.2 0.5 5.5 13.0 16.5 16.6 304.3 10:43 3000 164.0 520.0 12.3 499.2 0.8 5.8 13.3 16.7 16.8 316.6 10:45 3000 184.2 520.9 12.6 500.9 0.9 5.9 13.5 16.8 16.9 335.2 10:48 3000 208.0 520.9 13.1 502.0 1.0 6.1 13.7 16.9 17.0 354.5 10:50 3000 196.1 519.2 12.5 502.5 1.2 6.2 13.8 17.1 17.3 372.0 10:52 3000 202.6 517.4 11.8 501.0 1.2 6.3 14.0 17.2 17.4 386.8 10:55 3000 194.3 516.6 12.0 500.2 1.2 6.4 14.1 17.4 17.5 399.0 10:57 3000 194.5 517.4 11.5 499.4 1.2 6.5 14.2 17.5 17.7 408.6 11:09 3001 210.4 525.2 11.8 499.1 1.2 6.8 14.8 17.9 18.2 437.2 11:12 3001 211.8 525.2 12.2 499.5 1.2 6.9 15.0 18.1 18.3 441.5 11:33 2998 253.8 542.4 12.0 509.1 1.4 7.4 16.0 18.9 19.2 464.8 12:00 3002 324.9 546.6 12.9 515.3 1.9 7.8 17.0 20.0 20.3 490.7 12:02 2998 324.1 546.6 13.1 515.7 1.9 7.8 17.2 20.1 20.5 493.2 12:36 3002 359.9 546.6 15.6 532.2 2.0 8.2 18.1 21.0 21.5 506.1 12:38 3002 375.0 544.1 15.9 533.6 2.1 8.2 18.2 21.0 21.5 505.3 12:40 2998 385.7 544.1 16.5 535.1 2.1 8.2 18.2 21.0 21.5 504.4 13:40 2998 481.6 542.4 20.5 539.6 3.0 8.6 19.7 21.2 21.6 489.8 13:43 2998 490.6 549.2 20.2 537.5 2.9 8.6 19.8 21.1 21.6 489.8 14:12 3001 480.0 550.1 20.4 542.3 2.9 8.6 20.3 21.4 21.7 491.5 14:24 3002 479.2 552.7 20.3 547.7 2.9 8.6 20.5 21.4 21.8 493.2 14:57 3001 481.0 554.4 20.6 555.4 2.9 8.6 21.1 21.7 22.2 496.0 15:00 2997 481.8 552.7 20.7 555.1 2.9 8.6 21.1 21.7 22.2 496.0 七. 逻辑变更
1. 低压缸喷水电动门联锁开启逻辑条件(或): 1) 对应喷水调整门开度大于3%; 2) 对应排汽缸温度大于80℃(四取大); 3) FCB发生;
4) 机组负荷低于20%额定负荷。
2. 三级减温水电动门连锁开启逻辑条件(或): 1) 对应低旁开度大于3%;
2) 对应三级减温水调整门开度大于3%。
3. 凝结水至除氧器上水调整门旁路电动门联锁关闭逻辑
条件(或): 1) #1凝泵工频运行; 2) #2凝泵工频运行;