37,500 DWT DOUBLE SKIN BULK CARRIER
SC4421-010-02SM
Other stores or lockers (see General Arrangement Plan). 其它储藏室或柜子(参见总布置图)
1-2.4 Machinery spaces机械处所
Air conditioning room 空调室
Engine workshop 轮机员机修间
Electro workshop 电机员机修间
Battery room 蓄电池储藏室
CO2 bottle room CO2 钢瓶储藏室
Hydraulic oil pump room 液压油泵室
Windlass control room, etc. 锚机控制室等
1-3 NAME PLATE & IDENTIFICATION铭牌&识别牌
Name plate & identification to be provided as follows应按下述要求提供名牌&识别牌
Material材料 Plastic plate or Stainless steel塑料板或不锈钢 Stainless steel不锈钢 Used For用于 Name plate of room, guide plate (in accommodation quarter) 舱室名牌和指示牌(在居住舱室区) Letter文字 English and Russian or Chinese英文和 俄文或中文 Name plate of room (exposed to weather) 舱室名牌(露天部分) English and Russian or Chinese 英文和 俄文或中文 English and Russian or Chinese 英文和 俄文或中文 Plastic plate塑料板 In stairway of every deck showing deck name. Various safety marks. 用于楼梯中显示甲板名的牌子、各种安全标志 Russian labels to be supplied by the Owner.
A-5
37,500 DWT DOUBLE SKIN BULK CARRIER
SC4421-010-02SM
SECTION 2
JOINER WORK第2节-木工工作
2-1 DIVISIONAL BULKHEAD, LINING AND CEILING分隔舱壁、衬板和天花板
Construction of divisional bulkhead, lining and ceiling concerning fire protection to comply with requirements of SOLAS and Classification Society. 对于防火保护有关的分隔舱壁、衬板和天花板,其结构应符合SOLAS以及船级社的要求。
The arrangement of all walls, bulkheads, lining and ceilings in accommodation space to be in accordance with method 1C.
居住区墙壁、舱壁、衬板和天花板的布置应按照1C的方式进行。
Clear height in living space & service spaces mess room, passages and wheelhouse to be not less than 2,100 mm.
居住舱室&服务处所、餐厅、走道和驾驶室中的净高应不少于2.1米。
2-1.1 Bulkhead and Lining舱壁和衬板
Bulkhead and lining to be applied in accordance with the General Arrangement Plan.
舱壁和衬板应按照总布置图进行布置。
In corridors, enclosure living spaces and service spaces, bulkhead to be pre-fabricated panel system with max. 50 mm thick rock wool (glass wool only in certain place) with decorative PVC film on 0.7 mm thick galvanized steel sheet. 在走道、封闭的居住舱室和服务舱室中,舱壁由最大厚度为50mm的岩棉预制板(仅在一定的处所使用玻璃棉),预制板表面包扎有0.7mm厚镀锌簿钢板,且在最外表带有PVC装饰板。
0.7mm galvanized steel sheet painted to be used for sanitary space if in where heat insulation or sound isolation or fire insulation is used.
处所中采用隔热绝缘包扎或隔音包扎或防火绝缘包扎的部位,应采用0.7mm厚经油漆处理的镀锌簿钢板。
Bulkheads in galley and pantry to be covered with stainless panel system.. 厨房和配餐室中的舱壁应覆盖有不锈钢衬板系统。
2-1.2 Ceiling天花板
In corridors, enclosure living spaces, service spaces and control stations, ceiling to be pre-fabricated panel system with rock wool (glass wool only in certain place) with decorative PVC film on 0.7 mm thick galvanized steel sheet. Rock wool 25 mm thick to be accepted only.
在走道、封闭的居住舱室、服务舱室和控制站,其天花板将采用岩棉(仅在一定的处所使用玻璃棉)预制板体系,表面覆盖有经油漆处理且0.7mm厚镀锌簿钢板,仅厚度为25mm的岩棉板将被接受。
0.7 mm galvanized steel sheet painted to be used for sanitary if heat insulation is used in sanitary.
如果卫生间采用隔热绝缘包扎,则该卫生间将采用经油漆处理且厚度为0.7mm的镀锌簿钢板。
A-6
37,500 DWT DOUBLE SKIN BULK CARRIER
SC4421-010-02SM
Ceiling in galley and pantry to be covered with stainless steel sheet of 0.5 mm thick.
厨房和配餐室的天花板将覆盖有0.5mm厚的不锈钢簿板。
2-2 FIRE INSULATION, HEAT INSULATION AND SOUND ISOLATION防火绝缘、热绝缘和隔音绝缘
Fire insulation, heat insulation and sound isolation to be applied to accommodation quarter in accordance with relevant Rules as follows. 应按照下述相关规范的要求对居住区进行防火绝缘、隔热绝缘和隔音绝缘包扎。
2-2.1 Fire insulation防火绝缘
Fire fighting insulation to be complied with requirements of SOLAS. 防火绝缘包扎应满足SOLAS的要求。
2-2.2 Heat insulation隔热绝缘
The following boundaries to be insulated against heat transmission to the rooms. 下述舱壁应进行隔热绝缘包扎,以防止热量传入房间。
Where ceiling or lining is not fitted, rock wool to be covered with glass clothes, but sanitary space to be covered with galvanized steel sheet and painted.
对于未安装有天花板或衬板处,应采用覆盖有玻璃丝布的岩棉板进行包扎,但卫生舱室应覆盖有经过油漆的镀锌簿板。
Heat insulation to exposed part to be extended to about 500 mm beyond end of exposed part.
对于暴露部件的隔热包扎应从暴露部件末端延伸约500mm。
Material材料 50 mm rock wool with 25 mm beam cover. 50mm厚的岩棉+25mm厚的横梁包扎 75 mm rock wool with 25 mm beam cover 75mm厚的岩棉+25mm厚的横梁包扎 50 mm rock wool 50 mm厚的岩棉 Bulkhead exposed to weather of living space生活区露天的舱壁 Bulkhead of drying room and galley干衣间和厨房的舱壁
Note: Rock wool to be secured with galvanized steel pin and washer.
33
Rock wool density to be abt. 100 kg/m - 110 kg/m for heat insulation.
Application实施 Deck head where exposed to weather of living space, sanitary space, machinery space, and locker etc. Overhead of drying room and galley. 生活舱室、卫生舱室、机械处所以及柜子等露天的顶部,干衣间和厨房的顶部 Deck head of wheelhouse. 驾驶室顶部 A-7
37,500 DWT DOUBLE SKIN BULK CARRIER
SC4421-010-02SM
备注:岩棉将采用镀锌钢钉和垫片进行固定,隔热绝缘包扎的岩棉密度约为100
33
kg/m ~ 110 kg/m。 Engine casing wall to be fixed with tire insulation and to be secured with galva nized wire net and fastening pins/clips suitably placed.
机舱篷的墙壁上应安装防火绝缘包扎,并且在适当位置采用镀锌网和固定用钉子/扣钉进行固定。
2-2.3 Sound isolation隔音绝缘
Sound insulation to be applied to the wall between cabin and office or public space or or air conditioning unit room or sanitary space (except private lavatory) and engine control room.
房间与办公室或公共舱室或空调舱室或卫生处所(除了个人专用盥洗室)和机舱集控室间的墙壁上应采用隔声绝缘包扎。
2-3 DECK COVERING甲板敷料
Deck covering to be provided as follows: 甲板敷料的使用如下:
Material材料 A60 deck covering A60甲板敷料 Application使用 According to SOLAS requirement 按SOLAS的要求 2 mm thick P.V.C. tile or sheets on All living space and Corridors except 10mm latex type deck composition A60 class deck (except the spaces below furniture) 除A60级甲板外的所有居住舱室和走道 在10mm厚乳胶型甲板复合物上方贴有2mm厚PVC地砖或簿片。 Ceramic tile on cement (Anti-slip Galley, pantry, laundry and drying type) room厨房、餐具室、洗衣间和干衣室 在水泥上铺陶瓷地砖(防滑型) Paint (steel deck) 油漆(钢甲板) Store and locker space, Machinery space, all exposed steel decks and other similar spaces Except mentioned above. 储藏室和储藏柜、机械处所、所有暴露的钢甲板和其他类似舱室(上述除外) Mosaic tile on cement 在水泥地面上铺马赛克瓷砖
Navigation bridge wings to be covered with perforated rubber mat. 驾驶室翼桥应铺有带孔的橡胶垫。
All toilets and lavatories 所有厕所和盥洗室 A-8
37,500 DWT DOUBLE SKIN BULK CARRIER
SC4421-010-02SM
Gutter way in galley to be made with ceramic profile or stainless steel flat bars, stainless grating to be provided.
厨房中的水槽由陶瓷构件或不锈钢扁钢制成,且带有不锈钢格栅。
Bulkheads surrounding all sanitary spaces, galley, pantry, laundry and drying room to be with 150 mm height tile.
所有卫生舱室、厨房、餐具室、洗衣间和干衣间四周的舱壁应带有150mm高的瓷砖。
Only PVC tiles not to be fitted under furniture. 仅在家具下方不安装PVC地砖。
Floating floor deck cover to be placed on deck of engine control room and in superstructure main deck except working and store place...
除了工作和储藏处所外,机舱集控室和上层建筑主甲板将采用浮隔甲板敷料。
Non-skid type rubber mat to be provided in wheelhouse and in front and behind electrical switchboards.
在驾驶室和配电板前后将布置有防滑型橡胶垫。
Grating to be provided in steering gear room as per Class Rules. 舵机舱中布置有按船级社规范要求的隔栅。
Non-slip PVC tiles to be directly adhered to deck composition in wheelhouse and chart space.
在驾驶室和海图区甲板复合材料上方将直接粘贴有防滑PVC地砖。
Carpet on PVC floor to be laid IWO entrance of open place in highest, senior owner’s cabins, saloon, and size of carpet to be adjusted.
在船长级房间、高级船员房间、船东房间、酒巴间入口处PVC地板上应铺有地毯,并且地毯的尺寸应加以调整。
A-9